Ascon Tecnologic - e34B - OPERATING INSTRUCTIONS - PAG. 3

-2.0

Press and 

hold for 1s

Press and 

release

(e.g. 4.0°)

eco 10.0

(e.g. -5.0°)

trb -5.0

(e.g. 4.0°)

sp1

4..0

(e.g. 2.0°)

sp2

2.0

(e.g. 0.0°)

sp3

0.0

or

Press and 

hold for 5s

2.2 

Standard mode parameters programming

To access the instrument function parameters when pass-
word protection is disabled, press the keys 

/  and 

/  

at the same time and keep them pressed for about 5 s, after 
which the display shows the code that identifies the first pro-
grammable parameter.  Press the 

/

 keys to display the 

desired parameter, then, pressing the 

/  key, the display 

shows the parameter code alternated to its value that can be 
changed with the 

 and 

 keys.

Once the desired value has been set, press 

/  again: the 

new value is stored and the display shows only the code of the 
selected parameter.  Pressing the 

/

 keys, it is now pos-

sible to select another parameter and change it as described.
To exit the program mode, press no keys for about 30 s or 
keep the 

/  key pressed for 2 s.

-15.5

sPH

-20.0

Parameter select

(Program mode)

Previous

Parameter

Normal mode

Parameter set

Next

Parameter

2 s

5 s

Increase

value

Decrease

value

Note: 

With parameters in which the variable to be set is a time, 
the least significant time unit (s when s/min, min when 
min/h) is displayed in negative form (with the sign -); the 
most significant time unit (m when s/min, h when min/h) 
is displayed as a positive value (without the sign).

2.3 

Parameter protection using a Password

The instrument has a parameter protection function using a 
password that can be personalised through the 

PP

 parameter

To protect the parameters, set the desired password number 
in the parameter 

PP

.

When the protection is active, press the keys 

/  and 

/  

at the same time and keep them pressed for about 5 s, after 
which the display shows 

r.p

.  Now press only the 

/  key, 

the display shows 

0

; using the 

/

 keys, insert the pro-

grammed password number and press the key 

/  again.

If the password is correct the instrument displays the code of 
the first parameter and it will be possible to program the in-
strument in the same way described in the previous section.
The password protection can be disabled by setting 

PP

 = 

oF

.

spH

-15.5

0

Normal mode

Password

request

Parameter

(Program mode)

Insert password

2 s

5 s

Increase

value

Decrease

value

rp

Correct

password

inserted

Notes: 1. 

All parameters are configured by default at 
“protected” level so that setting the 

PP

 parameter 

protects all parameters with the password.

2. 

If the Password gets lost, just switch OFF and ON 
the instrument, push 

/  key during the initial 

test keeping it pressed for 5 s.  In this way it is 
possible to access all the parameters, verify and 
modify the parameter 

PP

.

2.4 

Customized mode parameter programming 

(parameters programming level)

The password hides all the configuration parameters behind a 
factory set password to avoid unwanted changes to the con-
troller parameters.  To make a parameter accessible without 
having to enter the password when 

PP

 password protection 

is activate, use the procedure that follows:
Enter the program mode using the 

PP

 Password and select the 

parameter that must be accessible (no password protection).
Once a parameter is selected, if the 

dp LED flashes

 the 

parameter is programmable by entering the password (is 

protected

”).  If the 

dp LED is steady ON

 the parameter is 

programmable without password (is “

unprotected

”).

To change the parameter visibility, press the 

/  key and 

keeping it pressed also press the 

 button.

The 

dp LED

 changes its state indicating the new level of 

parameter accessibility (

ON

 = not protected;  

flashing

 = password protected).

In case some parameters are not protected, accessing 
the the programming mode the device first shows the not 
protected parameters, then the 

r.p

 parameter (through which 

will be possible to access the “protected” parameters).

Previous

Param.

Not protected

parameters

Parameter set

Next

Param.

Increase

value

Decrease

value

AHA

 35.0

spH

-15.5

0

Normal mode

Password

request

Parameter

(Program mode)

Insert password

Correct

password

inserted

2 s

5 s

Increase

value

Decrease

value

rp

Содержание e34B

Страница 1: ...g the compressor electric heating or hot gas cycle inversion The controller is equipped with special defrost optimization functions and with other functions that can be used to obtain energy savings f...

Страница 2: ...el of the parameters Pressed together with the key for 5 s allows the keyboard unlock 5 LED dp Stand by During the normal operation is the decimal point when the instrument is placed in Stand by mode...

Страница 3: ...d is correct the instrument displays the code of the first parameter and it will be possible to program the in strument in the same way described in the previous section The password protection can be...

Страница 4: ...yable variable and its value So with the keys keys you can view all the variables pr1 Probe Pr1 temperature measurement Pr2 Probe Pr3 temperature measurement Pr3 Probe Pr3 temperature measurement Lt M...

Страница 5: ...nt con nection inside housing it is not equipped with either switches or internal devices to protect against current overloads the installation will include an overload protection and a two phase circ...

Страница 6: ...ng Elapsed the itt time after the door has been closed and from the activation of SPE Setpoint Eco mode by iEt parameter Eco Normal switching To use this function it is necessary to set the Digital In...

Страница 7: ...delayed for the time programmed with parameter iti The iFi parameter can be configured for the following functions 0 Digital input not active 1 Cell door opening with NO contact at input closure and...

Страница 8: ...ration can be used as a control of the shop window lighting anti fogging resistors or other utilities If present the internal buzzer can be configured by param eter obu for the following functions oF...

Страница 9: ...tions are disabled if the relative parameters are set to OFF oF 5 8 Defrost control The defrost control acts on the outputs configured as ot dF ad dH The type of defrost is set by the parameter ddt EL...

Страница 10: ...y occur with normal op eration when to ensure more system efficiency the defrost ing interval is programmed with a time that is often too short With the parameter ddd Defrost interval percentage reduc...

Страница 11: ...fine the display behaviour during defrost on The ddL parameter locks the display at the last Pr1 temperature reading during all the defrost cycle until at the end of defrost the temperature has not re...

Страница 12: ...l the alarm memory signal press any key It must be remembered that if an output function is desired with an alarm memory oo1 oo2 oo3 oo4 An n it is necessary to set the parameter AtA on 5 10 1 Tempera...

Страница 13: ...g 200 V off off off ON ON HU LU AL 10 V 10 V Volt time V 5 11 Function of keys and The key function can be defined using the tUF param eter to perform the following functions oF The key carries out no...

Страница 14: ...perature measured by the Pr1 probe using a 2 digit display Power supply TVR Y cable length 10 m max For more information see the user manual for the TVR Y device 6 4 RS485 Serial Interface with ARS1 D...

Страница 15: ...en Door with Fan Fn and Output ot Lock 4 External Alarm 5 External alarm with control output disabling 6 Normal Eco select 7 On Stand by select 8 Start a Turbo cycle 2 15 iti Digital Input Delay oF Di...

Страница 16: ...42 dEE Lengh of defrost cycle for evaporator probe error oF Function disabled 1 59 s 1 99 min 10 43 Ftn Fan time activation with ot output compressor OFF oF Function disabled 1 59 s 1 99 min 5 44 FtF...

Страница 17: ...tput function oF Function disabled 1 Control output ot delayed 2 Manual activation by key oF 69 otu Time relative to auxiliary output oF Function disabled 1 59 s 1 99 min oF 70 tUF Key Function oF No...

Страница 18: ...ust be shipped to Ascon Tecnologic with a detailed description of the faults found without any fees or charge for Ascon Tecnologic except in the event of alternative agreements 10 TECHNICAL DATA 10 1...

Страница 19: ...ERING CODE MODEL e34B Instrument with mechanical keyboard e34NB Instrument with NFC technology and mechanical keyboard a POWER SUPPLY H 100 240 VAC F 12 VAC VDC b OUTPUT 1 OUT 1 R Relay SPST NO 16A AC...

Страница 20: ...Ascon Tecnologic e34B OPERATING INSTRUCTIONS PAG 20...

Отзывы: