background image

C.A.P. offers a full range of equipment for the growing enthusiasts.  
The PPM-4 is the simplest, safest and most affordable CO

2

 controller 

available today… from any manufacturer. Perfect for controlling LP  
or natural gas generators with PPM accuracy.

Overview

 

•  The PPM-4 is a two-piece controller that includes  

a wall mounted infrared sensor with a 10 ft. cord  

and a plug-in pass-through controller/power supply. 

•  The plug in control is designed to be electrically safe.
•  Designed specifically to control the carbon dioxide  

level in your grow environment with PPM accuracy  

and is easy to use out of the box due to its easy to  

read 3 LED interface.

•  Switching set point factory set to 1450 PPM  

with 50 PPM hysteresis/dead-band.  

•  Calibration couldn’t be easier. Simply step outside  

and press a button.

•  The PPM-4 is easily mated to any 120 volt valve or  

CO

2

 Generator with a simple plug in device.

Installation

1.  Plug the controller into an active wall plug that will provide a  

constant source of power. Once plugged in the unit should  

illuminate the red “POWER” LED on the upper right face of  

the plug in unit indicating proper functioning. 

2.  Unwind the CO

2

 controller cable and plug it into the port at the 

top of plug in controller. The green LED on the front of the wall 

mount sensor should illuminate when power is provided to the  

plug in controller. This cable provides power and data transmission 

functionality to the unit and must be connected for the unit to  

work properly.

3.  Hang the controller by sliding the keyhole mounting hole on the 

back of the wall mount sensor over a nail or screw (provided)  

at the desired CO

2

 measurement location (typically at mid level 

between the ceiling and floor). You can either use a single  

screw or two screws spaced 3 

5

/

16

“ apart vertically.

4.  Plug the CO

2

 valve or generator into the wall-mounted 

plug-in controller. The “On” indicator light on the plug  

in unit will indicate when the power is switched on to  

your CO

2

 generator. 

 

Note: 

The controller can handle a maximum load of 10 amps. 

If this rating is exceeded the warranty will be void.

 

 

Operation

The PPM-4 controller has been factory programmed to provide  

an optimum CO

2

 maximum control set point of 1450 PPM. When 

levels are below 1400 PPM (a 50 PPM hysteresis/dead-band), the 

plug-in controller will power the CO

2

 generation source. When 

levels exceed 1450 PPM the controller will deactivate power at  

the plug-in controller.  
In most greenhouse operations CO

2

 is only generated when the 

plants are exposed to light. As a result you may wish to also include a 

timer with your setup. If using natural light, or a timer used to activate 

lighting, the plug in controller should be installed after the timer so 

that constant power is provided to the timer.

3

w w w . C A P C O n T r O L L e r s . C O M

10 ft. Connecting Cable

120 volts Plug-In  

Controller

PPM-4

 

CO

2

 Controller

PPM-4

 

CO

2

 Controller

5

/

16

Calibration  

Button

Отзывы: