MTFS SOLAR TIME CLOCK
The MTFS unit is designed to give you year round automatic control of pool systems employing a solar
heating system. It provides complete control of the filter pump and the solar pump. By following these
simple installation and operating instructions you will enjoy trouble free operation for many years.
THIS UNIT IS COVERED BY A 1 YEAR LIMITED WARRANTY. Please refer to web site for warranty
details.
CAUTION:
DO NOT OPEN THE CASE OF THE MTFS UNIT. IT IS NOT USER SERVICEABLE. IF THE POWER
CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER OR AN AUTHORISED
AGENT. OPENING THE CASE WILL VOID YOUR WARRANTY. ENSURE THAT THE MTFS AND
SURROUNDING AREA IS FREE FROM VERMIN INFESTATION
INSTALLATION
The MTFS unit is weather resistant, however it should be mounted in a sheltered position where it is not
exposed to direct weather, splashing or spray from the pool or filtration equipment.
Electrical building
regulations specify that theMTFS unit must not be mounted within 3.5 metres of the pool.
Fix the unit to a wall or post, within 1.5 metres of a 240 volt outlet and within 2 metres of the Solar pump
and the filter pump. Mounting points are provided on the back. Two sets of temperature sensor cables
are supplied. One short (3m) for the pool and one long (24m) for the roof. This MTFS unit must be
installed in the upright position. (Cables and mains sockets downwards).
Avoid cutting the sensor leads (excess can be neatly coiled). If the cable is cut, it must be
reconnected with the POSITIVE (stripe) to the POSITIVE, and the NEGATIVE (no stripe) to the
NEGATIVE. Do not place any wire joins underground.
Power connection.
Power is supplied through a standard 240 volt lead. A piggyback socket is provided on the lead if you
need to run other appliances from the same mains outlet.
Power for the solar pump comes from the left
hand side socket on the bottom of the unit, power for the filter pump comes from the right hand side
socket on the bottom of the unit.
Maximum pump rating
-
1.5HP per pump.
ONLY THE SOLAR PUMP AND FILTER PUMP ARE TO BE CONNECTED TO THE CONTROLLER’S
OUTLETS.
MORE THAN THIS WILL DAMAGE THE ELECTRONICS AND VOID YOUR WARRANTY.
TIMER OPERATION
The timer part of the MTFS unit primarily controls the filter pump. This can be set on or off in half hour
blocks, or overridden on or off. The solar part of the MTFS unit can also control the filter pump when it
requires to do so.
To set up the clock,
press the "TIMER" button, followed by the "SETUP" and "DISPLAY" buttons
together. The display will show "CLOC". Pressing the "+" button will advance the minutes, the "-" button
will advance the hours.
To clear the filter time blocks,
press the "TIMER" button and then press and hold down the "SETUP"
button for 5 seconds . This will clear all timer blocks and display "CLr".
To set up the filter time blocks,
press the "TIMER" button and then the "SETUP" button, and initially
"06.00" will be displayed. If filter is required to be on at this time, press the "+" button so the "SET ON"
LED is on, else press the "-" button so the "SET OFF" LED is on, or the "SETUP" button again, when the
block
time will increment to the next half hour block. Repeat until desired pattern is set up, then wait 5 seconds
until the displays return to their normal display.
To check the filter time blocks,
press the "TIMER" button, then the "DISPLAY" button. If the display
initially shows "End", then all the blocks are off. If the display initially shows "ALL", then all the blocks are
on. The display will normally show the first time in a day that the filter unit will go on at (indicated by the
"SET ON" LED being on). Further pressing of the "DISPLAY" button will show when the unit will go off
(indicated by the "SET OFF" LED being on) and so on until it displays "End", where there are no more
filter timer blocks to display.
SOLAR OPERATION
The solar part of the MTFS unit primarily controls the heating of the pool to a preset comfort setting using
solar heating when appropriate. It can control the filter pump when it requires to do so.
AUTOMATIC MODE
.
For fully automatic operation, simply plug it in and switch on. The unit will run the
pump for 6 minutes (decimal point after the P flashing), then make a decision to heat the pool based on
the sensor’s temperatures, activating the solar pump as required. When the pool has reached your preset
"comfort" temperature, it turns everything off and waits 4 hours before starting the process again.
Comfort Temperature Adjustment
Adjustment of the comfort level is achieved by pressing either the "+" or "-" buttons. The first operation
will simply display the present comfort temperature. Any further operation of the buttons will increase or
decrease the setting. The setting will automatically change if either button is pressed and held down.
This temperature will be stored permanently in memory, even with power off.
DISPLAY MODE.
To read roof, pool and comfort temperature settings, press the "DISPLAY" button. The
display will cycle through the settings showing an "R" for roof , a "P" for pool or "L" for Last and a "C" for
comfort.
DISPLAY MEANING (Lower display)
P28
L28
C30
R48
Pool temp
Last pool temp
Shows
Shows
when filter pump is on.
when filter pump is off.
Comfort setting 30°C
Roof temp 48°C
Pool is 28°C
Pool was 28 when
pump was turned off.
PPP
rrr
Flashing.
Flashing.
Faulty pool sensor,
Faulty roof sensor,
or pool temp outside 3° - 50° range
or Roof temp outside 3° - 98° range
NOTE:
When the filter pump is off, controller shows the L temperature as the pool sensor is no longer
reading a valid temperature.
WINTER MODE
.
The MTFS unit is equipped with a unique "Winter mode" facility which allows the user to exercise the
system daily throughout the colder months. By using this facility you will extend the life of your solar
heating by preventing pump seizure and drying of chemical build up in the collector.
To select winter mode
, press the "WINTER" button. The display will show "W"
and the unit will turn on
the solar pump for six minutes each time the filter pump comes on. For this function to work properly, at
least one on and at least one off period needs to be programmed into the timer.
To resume normal operation, press the "WINTER" button again and the unit will begin automatic
operation.