4
01.2011
© Ascom (Switzerland) Ltd.
Although the information in this publication is represented in good faith and believed to be correct, Ascom makes no representations or warranties
as to the completeness or accuracy of the information. In no event will be Ascom responsible for damages of any nature whatsover resulting from the
use of or reliance upon the information contained in this document. such information is subject to change without notice. Ascom gives no warranty
and makes no representation that any of its products contained in this document are designed for any particular use or purpose. the graphics and
contents of this document are the copyrighted work of Ascom and contain proprietary trademarks and tradenames of Ascom.
Technical Specification
System Management
Management GUI
Web GUI for configuring and monitoring TAN T,
remotely through IP network, or locally through
laptop/PC connected to service Ethernet port. GUI
framework allows for fast development of
customer specific GUIs, e.g. mission specific
configuration wizards.
Management Web
Services Interface
XML-RPC compliant web services interface for
configuring and monitoring TAN T nodes. Use
cases include integration of TAN T into existing
mission planning tools, or network management
solutions. This interface is service-oriented
architecture (SOA) compliant.
Configuration
Profiles
System and feature level configuration profiles
can be exported, imported, and activated without
rebooting TAN T.
SNMP
SNMP v1, v2c, and v3 compliant agent supports
remote monitoring of TAN T. Following MIBs are
available: MIB-II (RFC 1213 and successors), Host
Resources (RFCs 1514, 2790), SNMPv3 (RFCs
2571-5, 3411-3418).
Software Mainte-
nance
Remote and local software updates are
supported.
Built-In Self-Testing
(BIT)
TAN T hardware and software functions are
tested on boot and on demand. Test reports allow
for quick troubleshooting.
Local/Remote
Logging
Standard UDP based syslog for remote and local
logging of system events.
Environmental conditions
Temperature
-40..+55°C operation (with internal heating),
-40..+71°C storage
MIL-STD-810F, 501.4 proc I and II and 502.4 proc
I and II
Relative Humidity
95% RH
MIL-STD-810F, method 507.4, proc. 507.4-1, 10
cycles @ 60°C
Waterproof
MIL-STD-810F, method 506.4, proc. I (rain and
blowing rain 100mm/h, 40’ per surface)
EMC (industrial usage)
Emissions
MIL-STD-461E
Immunity
MIL-STD-461E
Mechanical
Watertight and hermetically sealed housing, carry handles or 19“
mounting adapters, hardened for military use
Size (LxHxD)/mm
400x110x265
Weight
10 kg
Cooling
Cooling functions without air exchange between
inside and outside the housing. If required, an
internal fan activates the airflow and optimises
the cooling.
Vibration
MIL-STD-810F, method 514.5, cat. 20, ground
mobile, proc. I, 1.04g rms, according tab.
514.5C-VII fig. 514.5C-1, 5-500Hz, 40’ per axis
Functional shock
MIL-STD-810F, method 516.5, proc. I, functional
shock/operation, 30g/11 ms
Shock, bench
handling
MIL-STD-810F, method 516.5, proc. VI
Available interfaces
Main Unit
Management
Ethernet
1 x 100Base-TX
Switched Ethernet
4 x 1000Base-T
Optical Ethernet
2 x 1000Base-X, multi mode or single mode fiber
modules for 0,5-160 km
Relay in
1 x
Relay out
1 x
Serial port
2 x RS-232
USB
4 x
Internal expansion units
ET P104
8 x E1 per unit
DSL P104
4 x G.SHDSL (2-wire) per unit
AtMUX-r
30 x a/b FXS or FXO per unit; configurable in
groups of 4; reserves 1xE1 port
ECOM P104
EUROCOM EES / D/1: 2xA (10 pin) or 4xB or 4xC
Power
Input voltage
22-50VDC or 230VAC with external power supply
Power consumption
Main unit
58W without heating
81W with maximum heating
Expansion units
ET P104: 3.1W
ECOM P104: 4.5W
DSL P104: 5.6W
AtMUX-r: 25W peak, 10W typical
Standard configuration
The standard configuration (T111) includes following units and
externally available interfaces:
1 x 10/100Base-TX,
2 x 10/100/1000Base-T,
2 x 1000Base-X, single mode
Relay with 1 x Relay in and 1 x Relay out (on one connector),
1 x RS-232
3 x E1
2 x EUROCOM EES D/1: A (10 pin) or C (on one connector)
2 x G.SHDSL (on one connector)
AT with 3 x FXS, 1 x FXO (on one connector)
Ascom (Switzerland) Ltd.
Belpstrasse 37
ch-3000 Berne 14
t + 41 31 999 13 65
F + 41 31 999 16 82
[email protected]
www.ascom.com/defense
Ascom (Austria) Ges.m.b.H
Lemböckgasse 49
1230 Wien
t +43 1 811 77 0
F +43 1 811 77 10
[email protected]
www.ascom.a
t
Ascom (Finland) Oy
pakkalankuja 6
FI-01510 Vantaa
t + 358 9 825 901
F + 358 9 825 902 79
[email protected]
www.ascom.fi
Ascom (CZ) s.r.o.
Zemské právo 1199/5
cZ-10200 praha 10
t + 420 267 219 512
F + 420 267 219 511
[email protected]
www.ascom.cz
product sheet: AscoM tActIcAL openAccess
®