INSTALLATION GUIDE
IP-DECT Base Station and IP-DECT Gateway
Appendix A
RFP Power Consumption
The tables below show power consumption for a base station connected to and powered from the IPBL.
The maximum cable length for base stations connected to the IPBL must not exceed 1500 meters.
A.1
KRCNB 201
Table 1 Power consumption (watts) of base stations and cabling when powered from the IPBL.
Cable
length
(metres)
0.4 mm wire
size
(Ø)
0.4 mm wire
size
(Ø)
0.5 mm wire
size
(Ø)
0.5 mm wire
size
(Ø)
0.6 mm wire
size
(Ø)
0.6 mm wire
size
(Ø)
Without EPP
With EPP
Without EPP
With EPP
Without EPP
With EPP
0
7.5
7.5
7.5
7.5
7.5
7.5
100
7.9
7.8
7.8
7.7
7.7
7.6
200
8.3
8.0
8.0
7.8
7.8
7.7
300
8.9
8.3
8.3
8.0
8.0
7.8
400
9.8
8.7
8.7
8.2
8.2
7.9
500
11.3
9.2
9.2
8.5
8.4
8.0
600
-
9.8
9.8
8.7
8.6
8.2
700
-
10.7
10.7
9.0
8.8
8.3
800
-
12.3
12.3
9.4
9.1
8.4
900
-
-
-
9.8
9.5
8.6
1000
-
-
-
10.3
9.9
8.8
1100
-
-
-
11.1
10.4
8.9
1200
-
-
-
12.3
11.1
9.1
1300
-
-
-
-
121
9.3
1400
-
-
-
-
-
9.6
1500
-
-
-
-
-
9.9
A.2
BS3x0 and DB1
Table 2 Power consumption (watts) of base stations and cabling when powered from the IPBL.
Cable
length
(metres)
0.4 mm wire
size
(Ø)
0.4 mm wire
size
(Ø)
0.5 mm wire
size
(Ø)
0.5 mm wire
size
(Ø)
0.6 mm wire
size
(Ø)
0.6 mm wire
size
(Ø)
Without EPP
With EPP
Without EPP
With EPP
Without EPP
With EPP
0
5.0
5.0
5.0
5.0
5.0
5.0
100
5.2
5.1
5.1
5.1
5.1
5.1
TD 92989EN / 25 January 2021 / Ver. E
32