TD 92232GB
2005-06-15 / Ver.G
Installation Guide
ELISE2
25
4.17 Unite Name Server (UNS)
The UNS is used to resolve addresses into complete Unite destinations. The ELISE2 can be
configured to send all requests to the local UNS (stand-alone mode) or to forward all
requests to a centralised UNS (forwarding mode). In forwarding mode, the local UNS will
only be used if the centralised UNS cannot resolve the address.
5
Maintenance Information
5.1
Replacement of the Compact Flash
Note:
Only Compact Flashes supplied by Ascom Tateco can be used.
1
Remove the cover, see
2
Perform a power down of the unit, see
Power Down and Restart of ELISE2
3
Remove the circuit board, see
4
Replace the Compact Flash.
5
Put the circuit board back into the cabinet.
6
If the Compact Flash is not preprogrammed with a valid IP address follow the
instructions in
4.12 Setup of Network Parameters
on page 20 else connect the
power cable.
7
Replace the cover.
5.2
Updating Application Software
The application software on the Compact Flash can be updated, for example if new
functionality for the application has been released. The version of the application software
has to be compatible with the ELISE2 operating system version. See
below for information about how to upgrade the operating
system.
1
Open the page xxx.xxx.xxx.xxx/system.
2
Press "Software". The current software versions for the application and ELISE2 are
shown.
3
Navigate to "Install software" and follow instructions.
Note:
The .eas files must be used to update the application software.
It is possible to update the software over a remote connection. However, note that it is not
possible to update software on the ELISE2 that handles the remote connection.