TD 92232GB
2005-06-15 / Ver.G
Installation Guide
ELISE2
20
Battery Data
Current consumption, real-time clock:
Battery life (battery connected):
Battery life (battery not connected):
Minimum 10 years.
4.12 Setup of Network Parameters
1
Set section one in SW3 to ON to set ELISE2 in "Network setup mode". The
remaining sections should be set to OFF.
Figure 18. Setting the ELISE2 in Network setup mode.
2
Connect ELISE2 Ethernet connector J20 either
• with crossover cable directly to a PC or
• with ordinary (straight through pinouts) cable via a HUB on the LAN to the PC.
Observe that it has to be the same LAN, i.e. same Ethernet Broadcast Domain.
3
Connect the power cable and wait until the Function Indicator indicates with
steadily orange light. ELISE2 now has the network setup IP address 192.5.36.229.
If the function indicator is red, check that supply voltage is 12.5 Vdc ±10%.
4
To be able to access ELISE2 from a PC, the PC has to belong to the same network as
ELISE2 or ELISE2’s IP address has to be found in the PC’s route table. To facilitate
this, the program "Route to ELISE" is provided.
Start the program "Route to ELISE". Press "Attach" to add the ELISE2 network
setup IP address to the route table.
5
Press "Launch config". This will open the page "192.5.36.229/system" in your
browser. The user ID is "admin" and the default password is "changeme".
6
Press "System Setup" and navigate to "Network". Set the network parameters.
Use the on-line help if any problems occur.
7
Navigate to "System 900" and select the bus operating mode for the module. The
modes are described in the on-line help.
Typical
Maximum
3V battery
3 µA
40 µA
Typical
Minimum
Power not connected 6 years
0.5 years
Power connected
10 years
1
OFF ON
8
SW3
026