These operating instructions are delivered with each

product. Malfunctions, damage or injury may occur

if these instructions are not followed.

DESCRIPTION

Series 342 Air Filter Regulators are designed for use in potentially
explosive atmospheres caused by gases, vapors, mists and/or dusts as
per ATEX Directive 2014/34/EU and standards EN ISO 80079-36.

Classification (Zone 1 and 21) : II 2 G Ex h IIC T5 Gb, II 2 D Ex h
IIIC T5 Db (T5- 90°C Ambient Temperature).The Classification
temperature depends on the ambient temperature. These regulators
are made of stainless steel with option compliant to NACE MR0175.
All metal on conductive parts must be inter connected and grounded.

Startup and maintenance are to be performed as detailed below.

General

This component is not a safety accessory. It is intended only for the
compliant use either as an individual component or incorporated in
an apparatus, machinery and installations. ASCO Stainless Steel Air
Filter Regulators are designed to be operated in accordance with the
limits specified in the nameplate or as specified in this document. All
applicable directives, legislations, orders and standards, as amended
from time to time, as well as state-of-the-art practices and procedures
must be observed for intended scope of application of the product.
Where applicable take all appropriate measure to ensure the
requirements are met. This device complies with the essential safety
requirements of the EU PED 2014/68/EU. Declaration of conformity
is available on request.

.

All assembly, operation, use and maintenance must be

performed by qualified, authorized personnel. Personnel working
with the components must be familiar with the applicable safety and
regulations relating to the components, apparatus and machinery
installations. In case of problems, please contact ASCO or one of its
authorized representatives in your region.

General Operating Specifications

Fluid : Instrument air, neutral, natural & Sour gas.

Ambient Temperature:

For manual drain: the temperature range

should be within -40

C to + 90

C (-40

F to +194

F);For Auto

drain: the range should be within 0°C to + 90°C (32°F to +194°F) ;

Inlet Pressure:

Do not exceed the maximum operating pressure

20

bar(290psi) for manual drain FR, 11bar(160psi) for auto drain FR

Quick relief

option available for standard operating temperature

-40°C to +90°C

INSTALLATION

Check the preliminary storage conditions required for the

component.

They must

be in accordance

to the product’s

specifications.

Carefully remove the Regulator from the packaging.

Power off and depressurize the apparatus, machinery or installation

designed to receive the FR.

Install the FR near where the air is to be used.

Install ASCO pressure gauge comes accessory on the frontal gauge

port. & Do Not modify the device.

Make sure that the fluid is compatible with the materials it contacts.

Operator or user must ensure that the gas group corresponds to the

product’s classification.

Check Nameplate for correct catalog number, pressure, temperature

and service. Never apply incompatible fluids or exceed pressure
rating of the regulator.

The installer must install the air filter regulator at the user’s

location in accordance with the requirements specified in Directive
99/92/EC.

Positioning

Installation &Maintenance Instructions

STAINLESS STEEL FILTER REGULATOR (High Flow)

SIZE : ¼” – ½”    

ST.STEEL VERSION

342 SERIES

Piping

Connect piping to valve according to markings on FR body.
Apply pipe compound sparingly to male pipe threads only. If
applied to FR threads, the compound may enter the FR and
cause functional difficulty. Avoid pipe strain by properly
supporting and aligning piping. When tightening the pipe, do
not use the FR as a lever. Locate wrenches applied to piping
as close as possible to connection point.
Direct Frontal mounting or mounting with brackets possible.

MAINTENANCE

NOTE: Ensure the air supply is completely stopped. It is not
necessary to remove the FR from the pipeline for repairs.

Cleaning

All FRs should be cleaned periodically. The time

between cleanings will vary depending on the medium and
service conditions. The most common part that requires
cleaning is the filter element.

Use running water for regular cleaning or a mild

detergent for cleaning the filter element. Do not use diluted
acids, strong detergents or corrosive chemicals.

For auto drain version clean the filter ring periodically.

Causes of Improper Operation

Incorrect pressure:

Check upstream pressure. Pressure

to FR must be within range specified on nameplate.

Excessive Leakage:

Disassemble FR and clean all parts.

If parts are worn or damaged, install a complete

ASCO

Spare Parts kit.

Manual drain operation:

Hold the knurling face of drain with fingers & rotate it to the
anti clockwise direction looking from top to unscrew the
manual drain to purge out the water that accumulated in the
bowl. After draining out, screw the manual drain back to its
original position & ensure proper working of AFR.

Automatic draining:

ASCO SS-AFR auto drain provides hassle free draining

of equipment which purge out the water accumulated in the
bowl

automatically.

Flexible

tube (Barb

connection)/

Hard piping (Adapter1/8”NPT-optional) can be used for
collecting the condensate. It also provides manual drain
feature integrated with automatic drain. Use spanner to
operate the same with the flat provided on it.

Page 1 of 3

Part Name

Torque Value

Pound-inches

Torque Value

Newton-Meters

M5 Screw in Filter Sub-Assy

90 ± 10

10 ± 1

All M6 Fasteners

Filter Sub-Assy to Body

Full Hand tight

Full Hand tight

Exhaust Filter 

(As Applicable)

70

± 10

8

± 1

Manual drain 

Full hand tight

Full hand tight

Auto drain

160 ± 10

18 ± 1

Adapter

160 ± 10

18 ± 1

Torque Chart

To Drain Rotate: (Looking From Top)
Anticlockwise  to drain, Clockwise  to close

Adapter1/8”NPT-

Optional

Auto  Drain  Manual 

Override

Manual  Drain

For optimum life and performance, the FR should be 

mounted vertically upright (Max. Inclination 5

°

).

ASCO Numatics (India) Pvt. Ltd.,
No. 57, Kundrathur Main Road, Gerugambakkam, 
Chennai-600128, India

Form No. IM-IND-430162 -001 Rev PB
ECN No : 305463 