ASCENTO REEFE VSRM Series Скачать руководство пользователя страница 3

ASCENTO GROUP AUSTRALIA        P: 1800 807 604     F: 1800 807 609     E: [email protected]

DANGER!

ALWAYS DISCONNECT 

THE PUMP FROM POWER 

WHEN INSTALLING, AND 

WHILE SERVICING OR 

REPAIRING. 

IMPORTANT! 

ALWAYS PRIME THE 

PUMP BEFORE STARTING. 

TIP! 

SOMETIMES YOU MAY 

HAVE TO DO THIS AFTER THE 

PUMP HAS STOPPED DUE TO A 

RUN-DRY EVENT

© Ascento Group Australia, 2016

DIAGRAM 10

DIAGRAM 11

DANGER!

ENSURE THE PUMP IS 

CONNECTED TO A 

DEDICATED POWER OUTLET 

THAT IS PROTECTED BY A 

SAFETY SWITCH (RCD) 

HAVING A RATED RESIDUAL 

OPERATING CURRENT NOT 

EXCEEDING 30mA.

TIP! 

IF YOUR 

PUMP STOPS, 

CHECK YOUR 

TANK, IT MAY 

BE EMPTY. 

IMPORTANT

FOR VERY LONG SUCTION/INTAKE PIPEWORK, IT IS CRITICAL THAT THE CORRECT PIPE SIZE IS USED AND THE PIPE 

IS FALLING ALL THE WAY TO THE PUMP. CHECK WITH A QUALIFIED PUMP TECHNICIAN FOR THIS TYPE OF INSTALLATION. 

INCORRECT! 

PIPES TOO SMALL!

!

WRONG!

DIAGRAM 9

WRONG!

MODEL

INLET INLET PIPE 

ID

OUTLET DISCHARGE 

PIPE ID

VSRM38-72 25BSP 25 - 32mm

25BSP

20 - 25mm

VSRM48-72 25BSP 25 - 32mm

25BSP

20 - 25mm

VSRM39-102 32BSP 32 - 40mm

25BSP

25 - 32mm

VSRM58-102 32BSP 32 - 40mm

25BSP

25 - 32mm

VSRM50-270 40BSP 40 - 50mm 40BSP 32 - 40mm

The larger size is recommended for best performance. Pipe 

sizes are Internal Diameter. We do not recommend 18mm 

copper piping for these pumps. 

1. 

Connect it to the water supply, ensuring you 

use the correct valves as per Diagram 1

2.  Remove the bleed plug off the front of the 

pump as indicated in the diagram (above 

the water inlet, as indicated)

3.  Open the ballvalve between the tank and the 

pump to allow the water to come through 

4.  Wait until the water spills out the bleed hole 

then re-fit the plug

5.  Start the pump - if the failure light flashes, 

repeat the process until it works.

To prime the pump - this is to fill it with 

water so it will start:

BLEED PLUG