Ascent Communication Technology AP201C Series Скачать руководство пользователя страница 5

AP201CW GPON 1 GE + WiFi ONT 

 

 

Solutions Provider for FTTx, RFoG and HFC www.ascentcomtec.com 

Page 5 of 26 

 

 

 

 

Do not place the equipment near flammable or conductive items, high temperatures (such as 
direct sunlight) or in wet conditions, or on a PC chassis, and check that the surrounding 
appliances are stable.

 

 

Check the cable for aging. Check and verify that the AC or DC input voltage is within the 
permissible range of the device and that the polarity of the DC is correct.

 

 

Unless the manufacturer permit, use the type of power indicated on the label and the adapter 
supplied with the product.

 

 

To prevent damage to the product from lightning, make sure that the ground of the power 
outlet and the power adapter is securely grounded. In the thunderstorm, be sure to unplug the 
power and all the connections.

 

 

Equipment input voltage fluctuation should be less than 10%, the power plug, refrigerators, hair 
dryer and iron should not use the same socket.

 

 

To avoid electric shock or fire due to overload of the power outlet, damage to the cord or 
damage to the plug, check the power cord regularly. If damage is found, replace it immediately.

 

 

Please place the device on a flat surface and cannot place items on the device.

 

 

Equipment is easy to produce heat when working, should maintain the appropriate cooling 
space to avoid damage caused by overheating products. The elongated hole on the shell is 
designed for heat dissipation. Keep the ventilation clean and avoid falling from the heat sink 
into the equipment. Otherwise, the equipment may be damaged or damaged. Do not spill 
liquid onto the surface of the equipment.

 

 

 

 

Please read the user manual carefully before using the equipment and follow all the 
precautions on the user manual and the product.

 

 

Avoid eye looked at the optical interface directly, so as to avoid the laser beam emitted by the 
interface damage the eyes. Please try to wear safety glasses to effectively protect your eyes 
from damage. It is best to plug in the fiber optic interface jacket when the optical interface is 
not in use.

 

 

Turn off the power when the device is not in use

 

 

Before plugging the power supply, make sure that the power switch is turned off to avoid surge. 
Be careful when unplugging the power supply and the transformer temperature may be high.

 

 

To ensure safety, do not open the enclosure of the device, especially when the device is 
powered up.

 

 

Unplug the power supply before cleaning the equipment. Use a soft dry cloth to clean the 
equipment to avoid the use of liquids or sprays.

 

 

Do not connect this product to any electronic product unless it is instructed by our customer 
engineer or your broadband supplier, as any incorrect connection may cause power or fire 
hazard.

 

Содержание AP201C Series

Страница 1: ...AP201CW GPON WiFi ONT Quick Reference Guide Revision A...

Страница 2: ...manner whatsoever without the express written permission of Ascent Communication Technology is strictly forbidden This document is produced to assist professional and properly trained personnel with...

Страница 3: ...ecautions for Use 5 2 Overview 6 2 1 Product Features 6 2 2 Product Specifications 7 2 3 WiFi Specifications 8 2 4 Device Interface Definition 9 2 5 LED Description 9 2 6 Device Connection 10 2 7 Appl...

Страница 4: ...6 2 Bridge Mode 19 7 IPTV Configuration 20 7 1 IGMP Snooping 20 7 2 IGMP Proxy 20 7 3 IGMP VLAN Configuration 21 8 WLAN Configuration 21 9 CATV Configuration 23 9 1 Configure CATV port parameter 23 1...

Страница 5: ...king should maintain the appropriate cooling space to avoid damage caused by overheating products The elongated hole on the shell is designed for heat dissipation Keep the ventilation clean and avoid...

Страница 6: ...rldwide It adopts dual fiber WDM technology with downlink wavelength 1490 nm uplink wavelength 1310 nm It only needs one core fiber to transmit data service It also have a HFC optical port received th...

Страница 7: ...m single mode fiber Data Transmission Parameters PON Throughput Downstream 2 488 Gbit s Upstream 1 244 Gbit s Ethernet 1000 Mbps Packet Loss Ratio 1 10E 12 Latency 1 5 ms Business Capability Layer 2 w...

Страница 8: ...M and 64QAM RF Receiver Sensitivity 802 11b 83 dBm 1 Mbps 80 dBm 2 Mbps 79 dBm 5 5 Mbps 76 dBm 11 Mbps 802 11g 85 dBm 6 Mbps 84 dBm 9 Mbps 82 dBm 12 Mbps 80 dBm 18 Mbps 77 dBm 24 Mbps 73 dBm 36 Mbps 6...

Страница 9: ...Provider for FTTx RFoG and HFC www ascentcomtec com Page 9 of 26 Indicator Description 1 WIFI WIFI Blinking Data is being transmitted On Wi Fi function Open Off Wi Fi function Close 2 LAN LAN port sta...

Страница 10: ...he fiber Insert the SC fiber connector into the PON connector on the rear panel of the ONU Connect the Ethernet cable Connect the RJ 45 Ethernet cable to any LAN LAN1 LAN4 port and each home device th...

Страница 11: ...FTTx RFoG and HFC www ascentcomtec com Page 11 of 26 Input UserName admin PassWord admin Click Login button the product basics page appears as follows You can start further configuration Select Intern...

Страница 12: ...G and HFC www ascentcomtec com Page 12 of 26 Fill in the following attribute fields with the pre assigned LOID and the password which can be empty click Sure Select Internet DHCP Server configure IP a...

Страница 13: ...side is obtained through the DHCP address pool of the ONT or by manually setting Bridge mode The ONT does not obtain the IP address assigned by the upper device or cannot manually set the static IP a...

Страница 14: ...PoE Enable vlan configure VLAN ID and priority Configure PPPoE user name and password and so on Service Mode select INTERNET 3 Optional binding LAN port and WiFi SSID to PPPoE wan Note By default all...

Страница 15: ...ider for FTTx RFoG and HFC www ascentcomtec com Page 15 of 26 4 Click Apply to apply WAN configuration 1 The first step is the same as PPPoE mode 2 Select WAN type as DHCP enable vlan configure VLAN a...

Страница 16: ...C www ascentcomtec com Page 16 of 26 3 Optional binding LAN port and WiFi SSID to DHCP wan Note By default all LAN ports and WiFi data are not bound by this WAN a LAN and WiFi SSID can only be bound t...

Страница 17: ...x RFoG and HFC www ascentcomtec com Page 17 of 26 1 The first step is the same as PPPoE mode 2 Select WAN type as static enable vlan configure VLAN and priority 3 Configure static IP address mask gate...

Страница 18: ...www ascentcomtec com Page 18 of 26 4 Optional binding LAN port and WiFi SSID to Static wan Note By default all LAN ports and WiFi data are not bound by this WAN a LAN and WiFi SSID can only be bound...

Страница 19: ...s Provider for FTTx RFoG and HFC www ascentcomtec com Page 19 of 26 1 Select Internet Internet config WAN Connection name select Add WAN connection Mode select Bridge 2 Enable VLAN configure VLAN and...

Страница 20: ...20 of 26 3 4 steps are the same as the last two step of PPPoE mode First create a bridge WAN for IPTV according to the bridging mode of 6 2 Select Application IGMP Config IGMP Snooping select Enable c...

Страница 21: ...HFC www ascentcomtec com Page 21 of 26 Select Application Multicast Vlan select the corresponding WAN click Modify configure multicast VLAN click Modify The default is not configured multicast vlan 1...

Страница 22: ...GPON 1 GE WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 22 of 26 2 Select Advanced SSID Type Network authentication mode select WPA2 Mixed input WPA Pre shared key WiFi p...

Страница 23: ...RFoG and HFC www ascentcomtec com Page 23 of 26 Select Management CATV config configure the parameter accoding to your requirement Apply Changes Select Management Backup Restore Restore The device wi...

Страница 24: ...nd HFC www ascentcomtec com Page 24 of 26 Select Management Firmware Upgrade Select firmware file after the application the device is upgraded to the latest software version Select Management Device S...

Страница 25: ...AP201CW GPON 1 GE WiFi ONT Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 25 of 26...

Страница 26: ...INA USA Unit 1907 600 Luban Road 2710 Thomes Ave Cheyenne 200023 Shanghai CHINA WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Du...

Отзывы: