INSTALLATION

IMPORTANT!!!  PLEASE READ BEFORE INSTALLATION

1) If the unit has recently been transported please let unit stand still for a minimum of 24 hours before 
plugging it in.
2) Make sure that the unit drops down to desired temperature before loading the unit with product.
3) Make sure that there is proper ventilation around the unit in the area where it will operate.
4) Make sure all accessories are installed (i.e. shelves, shelf clips, casters) before plugging the unit in.
5) Please read through the Operation / Owners Manual in its entirety.  Lack of maintenance or misuse of 
the unit will VOID warranty.  Please fill out the registration card and send it to the factory.

CABINET LOCATION GUIDELINES

1)  Install the unit on strong and leveled surfaces

-unit may make unpleasant noises if surface is uneven
-unit may malfunction if surface is uneven

2)  Install the unit in an indoor, well-ventilated area

-unit performs more efficiently in a well-ventilated area
-for best performance, please maintain clearance of 4" on the back of the unit
-outdoor use may cause decreased efficiency and damage to the unit

3)  Avoid installation in a high humidity and/or dusty area

-humidity could cause unit to rust and decrease effeciency of the unit
-dust collected on condenser coil will cause unit to malfunction.  Clean the condenser at least 
once a month with a brush or clean cloth
-malfunction due to dirty condenser will void warranty

4)  Select a location away from heat and moisture-generating equipment

-high ambient temperatures will cause the compressor to overwork, leading to higher energy bills 
and gradual breakdown of the unit
-malfuNction due to high ambient temperature will void warranty

ELECTRICAL

Please ensure that the required voltage of the compressor is being supplied at all times.  Low or high 
voltage can detrimentally affect the refrigeration unit and thereby void its warranty.
All units should be plugged into a grounded and properly-sized electrical outlet with appropriate 
overcurrent protection.  Please refer to the electrical requirements on the unit serial tag located inside the 
unit.  Please make sure that your unit has its own dedicated outlet.  Do not use an extension cord.

-3-

Содержание FD-23R

Страница 1: ...nt information regarding your new AS CE ND unit Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in...

Страница 2: ...NTY 1 Normal start up maintenance adjustments and cleaning 2 Damage caused by improper installation of the Ascend unit as outlined in this manual 3 Labor charges resulting from the inaccessibility of...

Страница 3: ...learance of 4 on the back of the unit outdoor use may cause decreased efficiency and damage to the unit 3 Avoid installation in a high humidity and or dusty area humidity could cause unit to rust and...

Страница 4: ...ck of the bracket first by sliding the opening a longer tab into the back pilaster and pull forward far enough to fit opening b into the front pilaster 2 Attach the front of the bracket by inserting t...

Страница 5: ...could cause damage to the compressor 1 To minimize shock and fire hazards please do not plug or unplug the cord with wet hands 2 During maintenance and cleaning please unplug the unit 1 To minimize s...

Страница 6: ...o not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash door gaskets on a regular basis preferably weekly Simply remove door gasket from the fram...

Страница 7: ...SEE PAGE 9 7...

Страница 8: ...8...

Страница 9: ...Offset on room temp 5 5 F 0 F E6 Offset on evap temp 5 5 F 0 F F1 Max defrost duration 1 60 min N A F2 Defrost interval time 0 24 hr 0 F3 Defrost termination temp 32 68 F N A Key F Farenheit degrees t...

Страница 10: ...on room temp 5 5 F 0 F E6 Offset on evap temp 5 5 F 0 F F1 Max defrost duration 1 60 min 30 min F2 Defrost interval time 0 24 hr 6 hr F3 Defrost termination temp 32 68 F 68 F Key F Farenheit degrees t...

Страница 11: ...denser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gasket s are sealing properly Cabinet tem...

Страница 12: ...allation and operation If certain recommended procedures are not followed warranty claims will be denied Notice Jimex reserves the right to make changes in design and specifications without prior noti...

Отзывы: