battery. It is recommended to do this occasionally 
to maximize battery life time.  
 
To replace battery, please follow these steps:  

a.

 

Remove the screws from the Battery Box 

b.

 

Remove the lid and control panel from 
the battery box slightly 

c.

 

Disconnect the battery connectors, then 
remove and replace the old battery. 
 

NOTES:

 Please make sure to connect the new 

battery correctly: Red for + and Black for - . Only 
original battery should be used for replacement 
as other alternatives may be incompatible and 
may damage the control panel 

and will void the 

warranty

. For parts, please go to 

www.allsolarcentral.com.

 

 

 

9.

 

TROUBLE SHOOTING 

 

Check to see if the solar panel, pump and 
led light are connected properly 

 

Check to see if the solar panel is correctly 
positioned facing the sun. Please ensure 
the solar panel is not in the shade or 
obstructed by trees, shrubs or a building 
(see step 2).  

 

Check if [low bat.] light is on. If so, this 
indicates that the battery power is low.  
Switch off the pump and leave the solar 

panel charging under direct sunlight for 1 
or 2 days. 

 

CHARGING TIPS:

 Press button [Power] to 

turn off the system.  All indicator lights 
should be off.  All solar power will now be 
used to charge the battery. 

 

Check water level and make sure the 
pump is fully submerged in water 

 

Check to see if the pump filter/impeller is 
blocked by debris 

 

Check to see if the fountain tubing is 
blocked by kinks or obstructions 

 

Check the pump.  It may be “air locked”.  
Turn the pump on/off switch several 
times to clear any air that may have been 
trapped. 

 

10.

 

TECHANICAL DATA 

 

Max. Water Flow: 800LPH 

 

Max. Water Lift: 200CM/6.5FT 

 

Max. Fountain Height: 110CM/3.6FT 

 

Working Voltage: DC15V – DC18V 

 

Pump Working Power: 3.6W – 6.3W 

 

Protection Grade of Pump: IP68 

 

Solar Panel: 8W; 18V; 0.444A 

 

Solar Panel Size: 358x238x18mm 

 

Protection Grade of Panel: IP44 

 

Battery: Lead-acid 12V/5AH 

 

Protection Grade of Battery Box: IP44 

 

LED Light Working Voltage: DC12V 

 

LED Light Working Power: 0.12W 

 

Protection Grade of LED Light: IP68 
 

 

11.

 

WINTER PROTECTION 

Indoor storage is recommended during winter 
months. Normal operating temperature is 
between 50 and 113 °F. Battery can be recharged 
at temperatures between 32 and 113 °F. 
 

IMPORTANT!! 

In order to keep your battery healthy during long 

storage times, please make sure the battery is 

fully recharged before storing. To do this, turn off 

the pump by pressing button [Power] and charge 

the battery for 1 or 2 sunny days. See Step 9 – 

Charging Tips 

Отзывы: