IPCOM-4G
1-2-3-4 Pass-Through mode
This mode is very similar to the first one, but with an important difference. In this mode, the event received over telco
interface will be acknowledged to the control panel after the event has been successfully reported to and acknowledged
by the server. This method is slower, but provides in most cases more reliable reporting.
1-3-5; 2-4-6 mode
This mode can be used, when the events has to be reported to two independent AMS. An IP, and mobile data channel
can be used for each AMS server
.
AES Encryption
The 128 bit AES encryption allows higher level of security for tranmission.
Channel settings
Ethernet
The device can send messages trough IP. Here we
need to ensure an IP adress or domain of the
receiver along with a port. Also we have to give an
account number in addition to choosing the internet
protocol (TCP/UDP) and the transmission protocol
(SIA DC-09, E2, Normal contact ID).
Mobile data (GPRS/3G/4G)
The device can send messages via mobile
data. Here we need to ensure the IP adress
or domain of the receiver along with a port.
Also we have to give an account number, in
addition to choosing the internet protocol
(TCP/UDP) and the transmission protocol
(SIA DC-09, E2, Normal contact ID).
SMS report
It is possible to send SMSs about the input changes, incoming messages from the alarm panel to one particlar phone
number. The SMS message contains information regarding the event includes the event code (603), the test period (060),
and the zone number (001) in case of alarm.
Lifetest SMS: E603-99 060 Test
Alarm SMS: E130-99 001 Burglary
SMS forwarding
We can assign one phone number to forward the
incoming SMSs. The module redirects every SMS
which is sent in a wrong way, or by the provider.
Page 10