1. Place the switch on a flat, stable surface.
2. Locate a rack-mounting bracket (supplied) and place it over the mounting holes on one side of the switch.
3. Use the screws (supplied) to secure the bracket (with a Phillips screwdriver).
4. Repeat the two previous steps on the other side of the switch.
5. Place the switch in the equipment rack.
6. Secure the switch by securing its mounting brackets onto the equipment rack with the appropriate screws
(supplied).
Important:
Make sure the switch is supported until all the mounting screws for each bracket are secured to the
equipment rack. Failure to do so could cause the switch to fall, which may result in personal injury or damage to the
switch.
2.2.1 Equipment Rack Guidelines
Use the following guidelines to ensure that the switch will fit safely within the equipment rack:
•
Size: 17.5 x 12.7 x 1.8 inches (440 x 234 x 45 mm)
•
Ventilation: Ensure that the rack is installed in a room in which the temperature remains below 104° F (40° C). Be
sure that no obstructions, such as other equipment or cables, block airflow to or from the vents of the switch
•
Clearance: In addition to providing clearance for ventilation, ensure that adequate clearance for servicing the
switch from the front exists
2.3 SFP Mini GBIC Ports
The GBIC Interface is the industry standard for Gigabit Ethernet Interfaces.
The Gigabit SFP module inserts into the Mini GBIC port to create a new Gigabit port. The hot-swapping feature on
the IntraCore IC3724PWR lets you install and replace the SFP transceivers while the system is operating; you do not
need to disable the software or shut down the system power.
To install the module, do the following:
1. Insert the transceiver with the optical connector facing outward and the slot connector facing down. The module
is keyed to help establish the correct position.
2. Slide the SFP transceiver into the slot until it clicks into place.
3. Remove the module’s rubber port cap.
4. Connect the cable to the Gigabit SFP module’s port.
Caution:
When replacing a SFP transceiver you must always disconnect the network cable before removing a
transceiver.
16
Asante IC3724PWR
User’s Manual
Содержание INTRACORE 3724PWR
Страница 1: ...IntraCore 3724PWR 24 Port FastEthernet 12 Ports PoE 2 Gigabit Combo L2 Management Switch User s Manual...
Страница 12: ...12 Asante IC3724PWR User s Manual...
Страница 78: ...78 Asante IC3724PWR User s Manual...
Страница 79: ...79 Asante IC3724PWR User s Manual...
Страница 87: ...MST Instance parameters can be modified on the following two screens 87 Asante IC3724PWR User s Manual...
Страница 92: ...TACAS and Storm Control are available on the next screens 92 Asante IC3724PWR User s Manual...
Страница 100: ...SNMP Continued 100 Asante IC3724PWR User s Manual...
Страница 101: ...10 10 LLDP 101 Asante IC3724PWR User s Manual...
Страница 102: ...102 Asante IC3724PWR User s Manual...
Страница 107: ...107 Asante IC3724PWR User s Manual...
Страница 108: ...108 Asante IC3724PWR User s Manual...
Страница 109: ...109 Asante IC3724PWR User s Manual...
Страница 110: ...Cable diagnostic a cable test that can be run for each port 110 Asante IC3724PWR User s Manual...
Страница 113: ...113 Asante IC3724PWR User s Manual...
Страница 114: ...114 Asante IC3724PWR User s Manual...
Страница 115: ...115 Asante IC3724PWR User s Manual...
Страница 116: ...10 13 Help General help is available for many screens 116 Asante IC3724PWR User s Manual...
Страница 117: ...10 14 Logout Use this screen to logout and close the session 117 Asante IC3724PWR User s Manual...
Страница 154: ...154 Asante IC3724PWR User s Manual bandwidth 57 configuration 57 monitoring 57 58 59 60...