Asante INTRACORE 3724PWR Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

IntraCore

®

 3724PWR 

24-Port FastEthernet/12 Ports PoE + 2 Gigabit Combo 
L2+ Management Switch

 

 

 

 

User’s Manual 

Содержание INTRACORE 3724PWR

Страница 1: ...IntraCore 3724PWR 24 Port FastEthernet 12 Ports PoE 2 Gigabit Combo L2 Management Switch User s Manual...

Страница 2: ...any associated artwork product design or design concept may be copied or reproduced in whole or in part by any means without the express written consent of Asante Asante and IntraCore are registered t...

Страница 3: ...1 1 Safety Overview 14 2 1 2 Recommended Installation Tools 15 2 1 3 Power Requirements 15 2 1 4 Environmental Requirements 15 2 1 5 Cooling and Airflow 15 2 2 Installing into an Equipment Rack 15 2 2...

Страница 4: ...6 3 Deleting Entries 33 Chapter 5 Managing the System and Configuration Files 34 5 1 Managing the System 34 5 1 1 Setting the System Clock 34 5 1 2 Specify the Hostname 35 5 1 5 Test Connections with...

Страница 5: ...t 50 6 3 3 Applying an Access List to an Interface 52 6 3 4 Enabling an Access List 52 Chapter 7 Power over Ethernet PoE 53 7 1 PoE Definitions 53 7 2 PoE Show Example 55 7 2 PoE Interface Settings Ex...

Страница 6: ...e Switch Using the GUI 66 10 1 Main Configuration Menu 67 10 2 System 68 10 3 Ports 72 10 3 1 Power over Ethernet PoE 77 Chapter 11 CLI Commands 118 Appendix A Basic Troubleshooting 148 Appendix B Spe...

Страница 7: ...rate broadcast domains with IEEE 802 1Q compliant VLANs and provide multimedia applications with multicast switching and CoS services The system can operate as a stand alone network or be used in comb...

Страница 8: ...Privileged Exec from Normal Exec Level RADIUS Authentication TACACS Authentication 802 1x Port Authentication HTTPS Port Security IP Filtering Username admin Password Asante Username admin Password A...

Страница 9: ...Power Management Mode Power Allocation Detection Type Enabled Dynamic without priority 15400 miliwatts IEEE 802 3af 4 Point Detection only Rate Limiting Input and Output Limits Disabled Port Trucking...

Страница 10: ...1 2 4 8 Disabled Disabled IP Settings IP Address Subnet Mask Default Gateway DHCP ARP 192 168 0 1 255 255 255 0 0 0 0 0 Client Disabled Enabled Multicast Filtering IGMP Snooping Disabled System Log Re...

Страница 11: ...lowing section describes the front and back panels of the IntraCore IC3724PWR Series switches The front panel of the IntraCore IC3724PWR contains the following power and port LEDs 24 10 100BaseT ports...

Страница 12: ...12 Asante IC3724PWR User s Manual...

Страница 13: ...he port 1 5 Management and Configuration The switch is managed using Command Line Interface CLI in order to access several different command modes Entering a question mark at each command mode s promp...

Страница 14: ...and to protect the switch from damage Note This information is a guideline and may not include every possible hazard Use caution when installing this switch Only trained and qualified personnel shoul...

Страница 15: ...e 50 60 Hz 2 1 4 Environmental Requirements Install the switch in a clean dry dust free area with adequate air circulation to maintain the following environmental limits Operating Temperature 0 to 40...

Страница 16: ...F 40 C Be sure that no obstructions such as other equipment or cables block airflow to or from the vents of the switch Clearance In addition to providing clearance for ventilation ensure that adequate...

Страница 17: ...fter the switch is connected to the network it can be configured for management capabilities see the following chapters for information on configuration 2 5 1 10 100 1000BaseT Ports Cabling Procedures...

Страница 18: ...4 1 Blue White 5 1 White Blue 6 3 Green White 7 4 White Brown 8 4 Brown White 2 5 2 Gigabit Ethernet Ports Cabling Procedures Cabling requirements for the optional hardware modules depend on the type...

Страница 19: ...Pair UTP cable up to 100 m 328 1 When attaching a workstation to the switch a standard straight through CAT5 cable may be used even when the workstation is attached via a patch panel No crossover cab...

Страница 20: ...tch 8 Attach a straight through serial cable between the RS232 console port and a COM port on the PC 9 Set up a HyperTerminal or equivalent terminal program in the following manner a Open the HyperTer...

Страница 21: ...g h Now that terminal is set up correctly power on the switch The boot sequence will display in the terminal After connecting to the console you will be asked for a password The initial default passwo...

Страница 22: ...ssigned to them By default each switchport belongs to VLAN 1 Use the following instructions to configure an IP address to the switch Follow the steps below to change the switch s IP address 1 Connect...

Страница 23: ...config Switch save Important To retain configuration changes after a system reload you must save changes made in running configuration From the privileged level configurations can be saved using the...

Страница 24: ...the system prompt provides a list of commands available for each command mode Document Conventions Command descriptions use the following conventions Vertical bars separate alternative mutually exclu...

Страница 25: ...to view all the commands that start with that letter with no space between the letter and the question mark Please note that there is no help on the arguments after a command is typed Use logout to l...

Страница 26: ...e diagnostic clear Command to clear switch configuration or statistics configuration Enter into global configuration mode copy Upload file from switch to host or download file to switch from host exit...

Страница 27: ...ation commands To exit global configuration command mode and return to privileged EXEC mode use one of the following commands Command Purpose exit Exits global configuration mode and returns to privil...

Страница 28: ...erface mode green eth Configure Green Ethernet enable or disable Switch Config From global configuration mode you can access three additional configuration modes Use the interface command to access it...

Страница 29: ...control Configure storm control on a port rmon counter Configure RMON counter capability on a port set Configure an IGMP router port spanning tree Configure port spanning tree vlan Configure VLAN pro...

Страница 30: ...elp because it reminds you which keywords or arguments are applicable based on the command keywords and arguments you already have entered Example of Context Sensitive Help The following example illus...

Страница 31: ...entry contents delete Remove the ACL entry enable Enable the ACL entry disable Disable the ACL entry set Set ACL entry contents Switch Config access list name acl_1 4 5 Using CLI Command History The C...

Страница 32: ...eleting Entries Scrolling Down a Line or a Screen Redisplaying the Current Command Line Transposing Mistyped Characters Controlling Capitalization 4 6 1 Moving Around on the Command Line Use the follo...

Страница 33: ...ecuted so that you may modify the command if necessary You may also enter a question mark to obtain a list of commands that begin with that set of characters Do not leave a space between the last lett...

Страница 34: ...Clock The IntraCore 3724PWRhas a battery backed system clock that is accurate even after a system restart To manually set the system clock complete the following commands in privileged configuration m...

Страница 35: ...another device on the network from the switch Command Purpose ping address Send an ICMP echo message to a designated host for testing connectivity 5 1 3 Enable the System Log The IntraCore 3724PWR se...

Страница 36: ...scribing the commands you have entered Precede a comment with an exclamation point 5 2 2 Copying Configuration Files to a Network Server You can copy configuration files from the switch to a file serv...

Страница 37: ...vram_config command loads the configuration files into the switch as if you were typing the commands in at the command line The switch does not erase the existing running configuration before adding t...

Страница 38: ...stem image from the server in case of system image file corruption To save the system image file of the switch to a TFTP server use one of the following commands in EXEC mode Command Purpose copy syst...

Страница 39: ...erting the SNMP manager to a specific event on the network Such events include improper user authentication restarts link status up or down closing of a TCP connection or loss of connection to a neigh...

Страница 40: ...omplex bridge on the network communicate with each other using special packets of data called Bridge Protocol Data Units BPDUs The information exchanged in the BPDUs allows the bridges on the network...

Страница 41: ...f two or more ports have the same path cost the STP selects the path with the highest priority the lowest numerical value By changing the priority of a port it can be more or less likely to become the...

Страница 42: ...the edge port will be in the RSTP initialization state and will send out the RSTP BPDUs with the operating status of edge port set to TRUE If the edge port starts receiving the BPDUs it will change th...

Страница 43: ...ommand Purpose spanning tree port force p2plink enable ports 1 2 Set link type of port 1 2 to point to point By default the link type is determined from the duplex mode of the interface a full duplex...

Страница 44: ...path cost are determined by the operating port speed For ports operating in 1000Mb speed the path cost is 20000 For ports operating in 100Mb speed the path cost is 200000 For ports operating in 10Mb...

Страница 45: ...For port priority the range is 0 240 in increments of 16 the default is 128 The lower the number the higher the priority 45 Asante IC3724PWR User s Manual...

Страница 46: ...eme It was possible that IP addresses would run out and routing tables would be overwhelmed Thus the Classless Inter Domain Routing CIDR addressing scheme was created CIDR replaces the older process o...

Страница 47: ...efer to local addresses as MAC addresses because the Media Access Control MAC sub layer within the data link layer processes addresses for the layer To communicate with a device on Ethernet you first...

Страница 48: ...he IGMP query timeout and the maximum query response time 6 2 1 IGMP Overview The Internet Group Management Protocol IGMP manages the multicast groups on a LAN IP hosts use IGMP to report their group...

Страница 49: ...MP querier Modifying the IGMP Host Query Message Interval Multicast switches elect a designated switch for the LAN subnet The designated switch is the one with the highest IP address The switch is res...

Страница 50: ...ority lower value than those with higher priority values The last match determines whether the software accepts or rejects the address In case of multiple matches the match in IP mode takes precedence...

Страница 51: ...traffic from 192 168 123 254 and allow all other traffic to be forwarded Switch Config access list name acl_ip add priority 1 Switch Config access list name acl_ip set ip mode srcip 192 168 123 254 25...

Страница 52: ...riority 1 Switch Config access list name acl_tcp_dst_smtp set ip mode l4port dst port from 25 to 25 Switch Config access list name acl_tcp_dst_smtp set portlist 7 Switch Config access list name acl_tc...

Страница 53: ...3af standard includes the ability to determine when a compliant Powered Device PD is connected to a port Power is only provided when a compliant device is detected As per the standard ports can be set...

Страница 54: ...mber 12 Total Allocation 0 1W 1000 Guard Band 0 1W 80 Management Mode Dynamic without priority Total Consumption 30700 Switch show poe port index portindex 1 2 Switch poe interface index Switch show p...

Страница 55: ...2 3af 4 Point Detection only Default 6 Enable NORMAL 15400 2900 IEEE 802 3af 4 Point Detection only Default 13 Enable NORMAL 15400 2900 IEEE 802 3af 4 Point Detection only Default 14 Enable NORMAL 154...

Страница 56: ...Detection PSE will provide power to PD without detection Legacy Capacitive Detection only PSE would provide three points to test PD s capacitance After a PD is successfully detected power is delivere...

Страница 57: ...t Switch Interface 1 poe power pri level Power priority level Switch Interface 1 poe power pri level low Set to low priority normal Set to normal priority middle Set to middle priority high Set to hig...

Страница 58: ...f tagging The following shows the commands available to configure VLAN s Switch Config vlan add Create a new VLAN delete Remove a existed VLAN port Configure 802 1Q port parameters for VLANs lag Confi...

Страница 59: ...arguments Use the following commands beginning in configuration mode to assign an IEEE 802 1q trunk port To create 3 vlans 2 3 4 with vlan 2 untagged port members 1 2 3 4 vlan 3 untagged port members...

Страница 60: ...e IFNUMBER Enter the interface number to access the interface configuration mode Vlan participation This command designates the interface to be a member of a vlan Use the no form of this command to re...

Страница 61: ...All the untagged frames are classified to the trunk port s native VLAN the VLAN whose VID matches the port s PVID The trunk port also sends out the frames as untagged for the native VLAN and tagged f...

Страница 62: ...duling algorithm There are 2 methods to schedule a packet to be transmitted from the switch strict priority and weighed round robin In strict priority the packet with the highest priority will be sent...

Страница 63: ...rities 0 7 and 4 internal queues Each packet can be assigned a priority based on which port it comes in 802 1P header or IP precedence DSCP in IP header if the packet is an IP packet The OQS configura...

Страница 64: ...signed to the packet by the switch 9 2 4 IP Based QOS The priority of an IP packet can be assigned based on the IP Precedence or DSCP value To set IP Precedence QOS use the following command in EXEC m...

Страница 65: ...gure traffic shaping for outbound traffic on an interface use the following command in interface configuration mode Command Purpose Switch config interface 5 Go to interface 5 Switch interface 5 rate...

Страница 66: ...to implement them refer to the chapters specific to that function At your web browser enter the IP address for the switch to launch the GUI Depending on settings you may receive a certificate error m...

Страница 67: ...configure the switch From this panel you can access the following screens System Port Management including PoE VLAN Management Spanning Tree Multicast Security QoS SNMP LLDP Admin Statistics Help Logo...

Страница 68: ...e first system screen up a name and location for the switch can be added A system contact can also be entered You can also view the Hardware Version Boot Version Firmware Version Build Date and the MA...

Страница 69: ...assign IP addresses to network interfaces Doing so enables the interfaces and allows communication with hosts on those interfaces using IP Associated with this task are decisions about subnetting and...

Страница 70: ...Broadcast When multiple networks are connected to the Internet the traditional classified addressing scheme could cause you to run out of IP addresses The usual way of assigning IP addresses uses the...

Страница 71: ...System Time Setting Use the Time Setting page to set the time zone or local time for the switch Daylight savings can also be enabled Click the Save Settings button when done 71 Asante IC3724PWR User s...

Страница 72: ...10 3 Port Management Port Config The Port Management section displays assorted settings for each port 72 Asante IC3724PWR User s Manual...

Страница 73: ...Port Management Port Config Specific Port Settings can be made on a per port basis When a port number is clicked the subscreen appears 73 Asante IC3724PWR User s Manual...

Страница 74: ...ment LACP Property The LACP properties are displayed on this screen The system LACP Priority can be set here By clicking on a port number a subscreen for each port is available 74 Asante IC3724PWR Use...

Страница 75: ...Port Management LACP Property Port Settings for each port can be entered Port Management LAG Group Click on a group number to set the groups properties 75 Asante IC3724PWR User s Manual...

Страница 76: ...Port Management LAG Group Each Group Once a link aggregation group is specified the screen below can be used to add ports to the group 76 Asante IC3724PWR User s Manual...

Страница 77: ...tic without priority This mode considers the used power is port s allocation and PSE first provides the power to the port which is first required Dynamic without priority This mode considers the used...

Страница 78: ...78 Asante IC3724PWR User s Manual...

Страница 79: ...79 Asante IC3724PWR User s Manual...

Страница 80: ...cation VLANs have the same attributes as a physical LAN but allow you to group end stations even if they are not located physically on the same LAN segment VLANs are usually associated with IP subnetw...

Страница 81: ...LAN group At the top of the main VLAN screen you can toggle between VLAN group information and VLAN port information by click on each link VLANs can be created one at a time or a range of VLANS can be...

Страница 82: ...GEMENT VLAN SETTINGS With a vlan selected ports can be marked as tagged or untagged Lover on the screen LAG groups can also be tagged or untagged Click Save Settings when done 82 Asante IC3724PWR User...

Страница 83: ...the PVID in required to force the port to respond to a particular VLAN Becoming a member of a VLAN is only the start The port PVID must be changed to cause it to respond only to the desired VLAN Vario...

Страница 84: ...ps or 100 Mbps port is the result of the equation Path cost 1000 LAN speed in Mbps Therefore for 10 Mbps ports the default port path cost is 100 For 100 Mbps ports it is 10 To allow for faster network...

Страница 85: ...he equation Path cost 1000 LAN speed in Mbps Therefore for 10 Mbps ports the default port path cost is 100 For 100 Mbps ports it is 10 To allow for faster networks the port path cost for a 1000 Mbps p...

Страница 86: ...MSTP Multiple Spanning Tree Protocol can be enabled on this page Individual Port properties can be manipulated at this screen 86 Asante IC3724PWR User s Manual...

Страница 87: ...MST Instance parameters can be modified on the following two screens 87 Asante IC3724PWR User s Manual...

Страница 88: ...10 6 Multicast Static multicast settings can be set Port by port participation can be controlled 88 Asante IC3724PWR User s Manual...

Страница 89: ...witch is responsible for sending IGMP host query messages to all hosts on the LAN By default the designated switch sends IGMP host query messages every 60 seconds in order to keep the IGMP overhead on...

Страница 90: ...ecurity Port Security Each port can be listed individually or a table can be displayed using the Show Table button Access control lists can be established using this screen 90 Asante IC3724PWR User s...

Страница 91: ...802 1X can be enabled on a per port basis Radius server can be identified at this screen A secret key can be created and the port can be altered 91 Asante IC3724PWR User s Manual...

Страница 92: ...TACAS and Storm Control are available on the next screens 92 Asante IC3724PWR User s Manual...

Страница 93: ...P list can be used to enter a list of IP addresses to limit the availability of switch Management Auto DoS provides protection from a variety of denial of service type of threats 93 Asante IC3724PWR U...

Страница 94: ...10 8 QoS Quality of service settings allow various protocols to be selected to protect functions that require real time performance and limit other traffic 94 Asante IC3724PWR User s Manual...

Страница 95: ...emented on this page There are eight queues available numbering 0 7 Click on the Mode selector to choose DSCP Then settings will be available to assign DHCP codes to the eignt queues 95 Asante IC3724P...

Страница 96: ...802 1P priory is supported to four queues Each priority level can be assigned to one of the four queues 96 Asante IC3724PWR User s Manual...

Страница 97: ...Port based QoS allows the priority for each port to be manually set Click the Update button when done to save changes 97 Asante IC3724PWR User s Manual...

Страница 98: ...Rate Control allows traffic shaping for each port An ingress rate limit can also be set 98 Asante IC3724PWR User s Manual...

Страница 99: ...ts PDUs The IntraCore IC3724PWR supports SNMPv1 v2 and v3 The SNMPv3 protocol has improved the authentication access control and security methods Use the following screens to set the read write access...

Страница 100: ...SNMP Continued 100 Asante IC3724PWR User s Manual...

Страница 101: ...10 10 LLDP 101 Asante IC3724PWR User s Manual...

Страница 102: ...102 Asante IC3724PWR User s Manual...

Страница 103: ...the screen that can be used to change the password Remember to click Save Settings when done L2 Table makes available MAC addresses and lists the port they are associated with Aging time can also be...

Страница 104: ...ic addresses can be added using this screen Dynamic ARP is the screen that allows aging time and trusted ports to be set on a per port basis Click Save Setting when done 104 Asante IC3724PWR User s Ma...

Страница 105: ...ed by checking the ingress mirror or egress mirror for the port Next select the port to mirror the information to Admin Timeout allows the timeout in seconds to be set before the management session is...

Страница 106: ...ADMIN Continued assorted administration functions are controlled using the next several screens 106 Asante IC3724PWR User s Manual...

Страница 107: ...107 Asante IC3724PWR User s Manual...

Страница 108: ...108 Asante IC3724PWR User s Manual...

Страница 109: ...109 Asante IC3724PWR User s Manual...

Страница 110: ...Cable diagnostic a cable test that can be run for each port 110 Asante IC3724PWR User s Manual...

Страница 111: ...DHCP Relay DCP Option 82 these screens control the relay of DHCP information from a server VLANS can also be specified to receive DHCP information 111 Asante IC3724PWR User s Manual...

Страница 112: ...10 12 Statistics RMON information and settings are controlled using the next screens General counters and timers are also displayed 112 Asante IC3724PWR User s Manual...

Страница 113: ...113 Asante IC3724PWR User s Manual...

Страница 114: ...114 Asante IC3724PWR User s Manual...

Страница 115: ...115 Asante IC3724PWR User s Manual...

Страница 116: ...10 13 Help General help is available for many screens 116 Asante IC3724PWR User s Manual...

Страница 117: ...10 14 Logout Use this screen to logout and close the session 117 Asante IC3724PWR User s Manual...

Страница 118: ...ode requires password authentication From Privileged Mode the operator can issue any Exec command to enter the Global Configuration mode The command prompt shown at this level is Command Prompt Switch...

Страница 119: ...C D Mode User Mode 11 1 5 show 1 show port This command displays port status Format show port port all Mode User Mode 2 show network This command displays switch IP configuration Format show network...

Страница 120: ...is used to clear RMON statistics for entire switch Format clear counters Mode Privileged Mode 11 2 2 4 clear IGMPsnooping This command is used to restore igmpsnooping configuration to factory default...

Страница 121: ...y tftp 192 168 1 100 file switch_configuration nvram_config Switch copy tftp 192 168 1 100 file runtime_code system_image 11 2 5 exit This command is used to exit current shell Format exit Mode Privil...

Страница 122: ...ged Mode 11 2 11 2 show dot1x This command display dot1x information 1 show dot1x config This command display dot1x and port configuration Format show dot1x config Mode Privileged Mode 2 show dot1x ra...

Страница 123: ...to display msap information Format show lldp msap Mode Privileged Mode 4 show lldp msap entry This command is used to display msap details information Format show lldp msap entry 1 26 Mode Privileged...

Страница 124: ...status Format show Rate Limit all Mode Privileged Mode 11 2 11 13 show running config This command is used to display switch running config Format show running config Mode Privileged Mode 11 2 11 14 s...

Страница 125: ...torm control Mode Privileged Mode 11 2 11 18 show sysinfo This command is used to display system information including system up time Format show sysinfo Mode Privileged Mode 11 2 11 19 show switch Th...

Страница 126: ...de Privileged Mode 5 Show rmon alarm Show rmon alarm index This command displays rmon Alarm Format Show rmon alarm index 1 65535 Mode Privileged Mode Show rmon alarm Format Show rmon alarm CR Mode Pri...

Страница 127: ...d Mode Global Config vlan ingress drop This command is used to drop frames violation vid Format vlan ingress drop Mode Global Config vlan ingress bypass This command is used to forward frame and learn...

Страница 128: ...lag vlan vlan ID tagged lags lag ID Mode Global Config 11 3 3 Bridge This command is used to configure switch aging time Format bridge aging time 0 1048575 Mode Global Config 11 3 4 lacp syspri This c...

Страница 129: ...drtxport A range of ports can be set Format lldp mgmt addrtxport ports port list Mode Global Config e g switch config lldp mgmt addrtxport ports 1 switch config lldp mgmt addrtxport ports 1 4 11 3 7 L...

Страница 130: ...dress can be set Format mgmt accesslist ipaddr IP addr Mode Global Config 11 3 10 2 mgmt accesslist enable This command enables management access list Only the IP address specified in the management l...

Страница 131: ...Mode Global Config e g Switch config dot1x port control disable port 1 4 11 3 13 network commands 11 3 13 1 network mgmt vlan This command changes management vlan Format network mgmt vlan vlan ID Mod...

Страница 132: ...e enable disable Mode Global Config 11 3 14 2 port all auto negotiate This command configures ports auto negotiation mode Format port all auto negotiate enable disable Mode Global Config 11 3 14 3 por...

Страница 133: ...Config 3 port all storm control broadcast multicast This command configures storm control for broadcast and multicast Format port all Storm Control broadcast multicast value Mode Global Config 4 port...

Страница 134: ...mmand configures queue weight for weight round robin Format qos wrr weight 1 15 queue 1 4 Mode Global Config 11 3 16 set commands 11 3 16 1 set IGMP Configure IGMP snooping 1 set igmp enable This comm...

Страница 135: ...cast name WORD delete This command delete a static multicast group Format set static mcast name WORD delete Mode Global Config 11 3 17 snmp commands 11 3 17 1 snmp notify This command configures snmp...

Страница 136: ...y name type both trap version 1 2 Mode Global Config snmp trapstation add ip addr community community name type none Send no trap Format snmp trapstation add ip addr community community name type none...

Страница 137: ...de Global Config 11 3 19 2 spanning tree configuration This command configures MSTP region name and revision 1 spanning tree configuration name This command configures MSTP region name Max 32 chars Fo...

Страница 138: ...creates a MST instance Format spanning tree mst instance add vlan vlan list mstpid MST ID Mode Global Config e g Switch Config Spanning Tree mst instance add vlan 2 5 mstpid 2 Switch Config Spanning T...

Страница 139: ...lobal Config e g Switch Config RMON alarm index 1 interval 10 interface counter 1 sample delta start all rthreshold 100 fthreshold 10 reindex 1 feindex 0 owner test 11 3 22 3 rmon del 1 rmon del event...

Страница 140: ...mand clears packet type filter Format access list name WORD clear packet type Mode Global Config 5 access list name WORD clear mac SA This command clears a source mac address Format Access list name W...

Страница 141: ...name WORD set IP mode packet type ICMP IGMP IP TCP UDP GRE Mode Global Config 5 access list name WORD set mac mode Specify ACL entry priority access list name WORD set mac mode mac SA This command sp...

Страница 142: ...GBIC SLOTS LAYER 2 MANAGEMENT SWITCH 11 3 25 1 dos land This Command enables and disables land type attacks prevention Format dos land enable disable Mode Global Config 11 3 25 2 dos Blat This Comman...

Страница 143: ...d current status of the system associated with its MSAP identifier The lldp agent can also receive information about the capabilities and current status of the system associated with a remote MSAP ide...

Страница 144: ...100FX mode 1000base x full Format speed 10hd 10fd 100hd 100fd 1000fd 100fx 1000base x Mode Interface Config 11 4 10 flow control command flow control enable This command enable flow control at port F...

Страница 145: ...Kbps and 0 means no limit Format storm control broadcast unknown rate Mode Interface Config e g Switch Interface 1 storm control broadcast unknown 64 11 4 14 5 storm control all cast This command sto...

Страница 146: ...e priority this command configure RSTP port priority 0 240 format spanning tree priority 0 240 mode Interface Config 11 4 18 VLAN command 11 4 18 1 vlan participation This command join or leave a vlan...

Страница 147: ...t to high priority Format poe power pri level low normal middle high Mode Interface Config 11 4 20 3 detection This command configures detection type on a port set to 0 1 2 3 4 or 5 0 No Detection 1 L...

Страница 148: ...hapter 2 6 Connecting to the Network for more information The GBIC Link LED is not lit Check the GBIC connector Make sure the cables are inserted correctly with the Transmit Tx connector on one side o...

Страница 149: ...EEEE 802 1q 255 VLANs Spanning Tree IEEE 802 1d STP IEEE 802 1s multiple IEEE 802 1w rapid reconfiguration fast link Flow Control IEEE 802 3x Link Aggregation IEEE 802 3ad LACP up to 6 trunks Authenti...

Страница 150: ...oduct should never be placed near or over a radiator or heat register This product should not be placed in a built in installation unless proper ventilation is provided 8 This product should be operat...

Страница 151: ...ot limited to cables brackets and fasteners included with the covered product nor to any discontinued product i e product purchased more than thirty days after Asante has removed such product from its...

Страница 152: ...queuing 58 Quality of Service 57 rate limit 60 SNMP Configuration GUI 89 traffic shaping interface 60 VLAN 71 weighted fair queuing 57 Connecting console 13 20 network 17 PC 22 power 17 Console baud...

Страница 153: ...ng configuring 58 examples 59 monitoring 59 Quality of Service configuration 57 priority queuing 58 traffic shaping 60 weighted fair queuing 57 Rapid Spanning Tree edge port 43 link type 43 port path...

Страница 154: ...154 Asante IC3724PWR User s Manual bandwidth 57 configuration 57 monitoring 57 58 59 60...

Отзывы: