Adding and deleting untagged sets 

• 

Sharing and unsharing VLANs 

• 

Inserting and removing MAC addresses 

• 

Toggling management access 

 
To access the VLAN Management Menu, type 

in the Configuration Menu. A screen similar to the following 

will appear: 
 

IntraCore 3524 VLAN Management Menu 
 
VLAN Version:                   1     VLAN Type:               Port Based 
Max. Supported VLAN ID:      4094     Max. Supported VLANs:    64 
Number of VLANs Configured:     1     Number of Active VLANs:  1 
 
 
<Cmd>     <Description> 
  v       VLAN Group Static Configuration 
  p       VLAN Port Attribute Configuration 
  d       Display VLAN Groups Summary 
  a       Display Port VLAN Attribute Summary 
  r       Reset VLAN Configuration to Factory Default 
  q       Return to previous menu 
 
Command>

 

 

4.4.2 Configuring Static VLAN Groups 

 
To access the VLAN Group Static Configuration Menu, type 

in the Configuration Menu to access the 

VLAN Management Menu, then type 

again to access the VLAN Group Static Configuration Menu. A 

screen similar to the following appears: 
 

IntraCore 3524 VLAN Group Static Configuration Menu    VID: [0002] 
 
Name: test2                             Created By: Mgmt 
Mgm Access: Enable          Status: Active 
Unit     Port List  1      8  9     16  17    24  25    32 
======              ========  ========  ========  ======== 
1                   --------  --------  --------  -KXXXXXX    +: static 
2                   --------  --------  --------  KKXXXXXX    d: dynamic 
3                   --------  --------  --------  KKXXXXXX    -: Not Member 
4                   --------  --------  --------  KKXXXXXX    K: Stacking 
5                   --------  --------  --------  KKXXXXXX 
6                   --------  --------  --------  KKXXXXXX 
7                   --------  --------  --------  KKXXXXXX 
8                   --------  --------  --------  KXXXXXXX 
 
<Cmd>     <Description>                 <Cmd>     <Description> 
  c       Create VLAN                     r       Remove VLAN 
  e       Set VLAN Name                   t       Toggle Mgmt Access 
  m       Move ports to this VLAN         d       Delete Port Members 
  o       Overlap Ports To This Vlan      f       Display Vlan-Grp Information 
  l       Toggle To Vlan-prt Config Menu 
 
Command> 
S)elect VID     N)ext VLAN    P)rev VLAN    H)elp     Q)uit

 

 
Navigate to the VLAN that you want to configure by typing a command (

s

n

 or 

p

) as shown at the bottom of 

the screen. With the Select command, you select a VLAN by its VLAN ID (VID); you can type the VID of an 
existing VLAN, or the VID of a VLAN you will create. 
 

Содержание IntraCore 3524 Series

Страница 1: ...IntraCore 3524 Series Gigabit Ethernet Switches User s Manual...

Страница 2: ...itch 2 Install the switch in an equipment or wall rack or prepare it for desktop placement 3 Connect the power cord to the unit and to an appropriate power source 4 Connect network devices to the swit...

Страница 3: ...ll rights reserved No part of this document or any associated artwork product design or design concept may be copied or reproduced in whole or in part by any means without the express written consent...

Страница 4: ...guration 23 3 7 Port Configuration 25 3 8 Advanced Port Configuration 28 3 9 Unicast Forwarding Database Configuration 30 3 10 Security Management 32 3 11 VLAN Management 32 3 12 IP Multicast Traffic...

Страница 5: ...hing Concepts 70 7 1 VLANs 70 7 2 Spanning Tree Protocol 71 7 3 Full Duplex Flow Control and Auto negotiation 72 Appendix A Troubleshooting 74 Appendix B Features and Specifications 75 B 1 Features 75...

Страница 6: ...ort 10 100 switch base IC 3524 2G 24 Two 1000BaseX GBIC slots Integrated 1000BaseX GBIC slots IC 3524 2T 24 Two 10 100 1000 BaseT ports Integrated copper Gigabit ports Table 1 1 3524 Modules The syste...

Страница 7: ...ion 25 26 Gigabit speed Solid Green Off A valid 1000Mbps link has been established No link has been established or link is at 10 100Mbps rate 25 26 10 100 Link Solid Green Solid Amber Off A valid 100M...

Страница 8: ...ers must use a console connection to form a stack multiple units sharing one IP address See Chapter 2 11 Using the Stacking Feature for more details 1 4 2 Web Based Interface With Internet access user...

Страница 9: ...guideline and may not include every possible hazard to which you may be exposed Use caution when installing this switch Only trained and qualified personnel should be allowed to install or replace th...

Страница 10: ...direct sunlight heat sources or areas with high levels of electromagnetic interference 2 1 5 Cooling and Airflow The IntraCore 3524 uses internal fans for air cooling Do not restrict airflow by coveri...

Страница 11: ...i mode fiber GBIC 1000LX 99 00550 01 1000BaseLX Single mode fiber GBIC 1000T 99 00673 01 1000BaseT Category 5 UTP copper GBIC 1000TP 99 00647 07 1000BaseT Category 5 UTP copper Table 2 1 GBIC Modules...

Страница 12: ...e optical bore Use an alcohol swab or equivalent to clean the ferrules of the optical connector 2 4 Installing Optional Hardware Modules Follow the steps below to install your media modules 10 100 100...

Страница 13: ...ur network devices Connecting to Network Station Category 5 UTP Unshielded Twisted Pair straight through cable 100 meters maximum with RJ 45 connectors Connecting to Repeater Hub Switch s Uplink port...

Страница 14: ...changing from the default IP address and configuring the SNMP host table In order to configure the switch you will need to connect to it through a console out of band management through your web brows...

Страница 15: ...s the switch 192 168 0 X For more information on how to configure your TCP IP settings please refer to your computer manufacturer s user s manual You may now run a telnet session to configure and mana...

Страница 16: ...entication traps This menu also allows you to specify which of your network management stations will receive traps from the switch The n option in the Configuration Menu displays the SNMP Simple Netwo...

Страница 17: ...lnet or web interface the initial formation of the stack may only be done by connection to a console The switches need no extra software but they must all have the 1 1 firmware installed see Chapter 3...

Страница 18: ...ading Configuration k Stack management r System Reset Options l System Log u User Interface Configuration y System Utility q Return to previous menu Command IntraCore 3524 Stack Management Configurati...

Страница 19: ...as shown After logging in the Main Menu appears as shown below IntraCore 3524 Remote Management System Version 1 10 Compiled Date Dec 05 2001 13 53 58 Asante Technologies Inc Copyright c 2001 Asante T...

Страница 20: ...for 001day s 17hr s 27min s 54sec s Software Version Bank 1 Image Version Date 1 10 Dec 05 2001 13 54 06 Bank 2 Image Version Date 1 10 Dec 05 2001 13 54 06 Running System Information PROM Image Versi...

Страница 21: ...st of the configuration options are described in detail in the rest of this chapter The more advanced options are discussed in Chapter 4 Advanced Management 3 3 System Administration Configuration The...

Страница 22: ...IP Information To change the IP address subnet mask or default router of the IntraCore 3524 use the following procedure 1 Open the System IP Configuration Menu by typing i in the Configuration Menu 2...

Страница 23: ...n the Configuration Menu displays the SNMP Simple Network Management Protocol Configuration Menu as shown below IntraCore 3524 SNMP Configuration Menu SNMP Read Community public SNMP Write Community p...

Страница 24: ...attempts to read or change data without the proper community string To set the switch to generate traps use the following procedure 1 Open the SNMP Configuration Menu by typing n in the Configuration...

Страница 25: ...ears Type the unit number you wish to configure and press Enter System Unit Map Please select one of the following slots Slot Description Unit Type 1 IntraCore 3524 Unit 2 IntraCore 3524 Unit 3 none 4...

Страница 26: ...e Configuration Menu 2 If necessary select which unit to be configured on the System Unit Map and press Enter 3 To select the port you want to enable or disable type s n or p in the Basic Port Configu...

Страница 27: ...the stack type u to select the unit The link speed is changed immediately and the change is reflected in the Link Speed line near the top of the Port Configuration Menu Toggling Half to Full Duplex H...

Страница 28: ...can enable flow control for a port that port must be configured to operate in Full Duplex mode If you enable flow control on a port and that port runs short of buffer resources the port will transmit...

Страница 29: ...ty on another unit in the stack type u to select the unit The new default priority is shown on the Advanced Port Configuration Menu 3 8 4 Global Port Configuration The Global Port Configuration Menu a...

Страница 30: ...ess Count 10 Cmd Description a Display All Forwarding Database With Without IP p Display Forwarding Database By Port With Without IP v Display Forwarding Database By VLAN With Without IP m Search for...

Страница 31: ...nu 2 Type m to search for a MAC address Type i to search for an IP address 3 Type the MAC or IP address at the prompt 4 Press Enter If the address is located it is displayed with its associated inform...

Страница 32: ...ng System Port Mirroring To enable or disable port mirroring use the following procedure 1 Type m in the Configuration menu to display the Port Mirroring Configuration menu 2 If necessary select which...

Страница 33: ...ion The Image File Downloading Configuration Menu allows you to upgrade your IntraCore 3524 system easily using either TFTP or X Y Z modem protocol Type f in the Configuration Menu to access the Image...

Страница 34: ...nfiguration Menu by typing t in the Image File Downloading Configuration Menu 2 Type s to set the image server IP address 3 At the prompt enter the IP address of the server containing the image file t...

Страница 35: ...rmation about these protocols see the manual for your communications software 3 Type c to select the console baud rate The Baud Rate Setting Menu appears The maximum baud rate currently supported is 5...

Страница 36: ...ation Menu 2 Type r d or i Typing r resets the switch to its current configuration Typing d resets switch to the factory default Typing i resets the switch to the factory default but without affecting...

Страница 37: ...7 004 17 30 33 2 unit Software Stack is out of service Specast 8 004 17 50 02 2 unit Software Stack is back running Specast 9 004 19 09 08 REDO fail ifnCFGSetPortStatus in the unit 1 10 004 19 26 35...

Страница 38: ...dministrator Password a Add Access host d Delete Access host o Toggle to Enable Disable HTTP Server q Return to previous menu Command 3 17 1 Setting Console Idle Time out Period Use the following proc...

Страница 39: ...up to a maximum of 20 characters in length The password characters can be any ASCII code 4 Press Enter 5 Type the new password again at the confirmation password prompt To cancel the change in passwo...

Страница 40: ...t 0 0 Dropped Pkts 0 0 Undersize Pkts 0 0 Oversize Pkts 0 0 CRCAlign Errors 0 0 Fragments 0 0 FCS Errors 0 0 Collisions 0 0 Late Events 0 0 64 Byte Pkts 0 0 65 127 Pkts 0 0 128 255 Pkts 0 0 256 511 Pk...

Страница 41: ...ging loops which can generate excess broadcast traffic that can bring down an entire network See Chapter 7 Switching Concepts for a more detailed explanation 4 1 1 Enabling and Disabling STP The switc...

Страница 42: ...n Menu IntraCore 3524 Spanning Tree Port Configuration Menu Unit 1 Port 01 Port Speed 10 Mbps Port Status Enabled Port State Forwarding Port MAC Address 00 00 94 CC C7 6D Port Priority 0x80 Port Path...

Страница 43: ...witch are described in Chapter 6 SNMP Management The IntraCore 3524 switches provide control of the RMON groups only through SNMP For information on controlling RMON groups please refer to the documen...

Страница 44: ...uplicated IP trap Viewing a List of Duplicated IP Addresses To view a list of duplicated IP addresses that have been detected at the switch 1 From the Configuration Menu type t to access the Security...

Страница 45: ...nt in the current address table The information shown in the alert is the new node s MAC address and IP address if available and the port to which they are connected Once a device has been connected a...

Страница 46: ...the switch locks out the intruder s MAC address the port will not accept any traffic from that station The intruder s address is then re enabled only by clearing the security level by management Impo...

Страница 47: ...f the actual physical configuration of a network The IntraCore 3524 supports port based VLANs in compliance with the IEEE 802 1Q standard The following sections describe how to configure and manage VL...

Страница 48: ...to access the VLAN Management Menu then type v again to access the VLAN Group Static Configuration Menu A screen similar to the following appears IntraCore 3524 VLAN Group Static Configuration Menu V...

Страница 49: ...If security is a concern for members of a particular VLAN disabling management access for that VLAN will prevent any member of that VLAN from attempting to change the switch s configuration To enable...

Страница 50: ...configure by typing a command u s n or p as shown at the bottom of the screen IntraCore 3524 VLAN Port Configuration Menu Unit 1 Port 01 Port VLAN ID PVID 0001 Acceptable Frame Type All Frames Port I...

Страница 51: ...configured to receive only tagged frames any untagged frames received by the port are dropped and the source address of the untagged frames is not learned Incoming tagged frames are forwarded to the...

Страница 52: ...kets to a single host unicast transmission or to all hosts broadcast transmission IP multicast provides a third scheme allowing a host to send packets to a subset of all hosts group transmission Multi...

Страница 53: ...ic Management Menu allows you to set up group transmission To access the Multicast Traffic Management Menu type c in the Configuration Menu You will see a screen similar to the following IntraCore 352...

Страница 54: ...N ext VLAN P rev VLAN Select A ddr Nex t Addr Prev Addr Use the commands at the bottom of the menu to select a VLAN or Multicast Group address Adding Ports to the Selected Address To add or delete po...

Страница 55: ...or console connection see User Interface Configuration in Chapter 3 Note When forming a stack only the Master unit needs to have the Web browser interface enabled Accessing with a Web Browser Once you...

Страница 56: ...te IP Duplicate IP Trap Log The following sections describe and explain the pages that are displayed when you click each of the buttons 5 1 Front Panel Button This button opens or refreshes the Web Br...

Страница 57: ...the statistics counters see Viewing Statistics in Chapter 3 The following features allow you to modify the statistics bar chart Up Down Arrows The up and down arrows let you scroll the screen up to v...

Страница 58: ...ng the cursor on the desired bar A box with the statistics appears To see either a line graph or a table display of the system s statistics click on a bar then choose the option you want from the pop...

Страница 59: ...of the IntraCore as shown below STP configuration is explained in Chapter 4 Advanced Management Click the STP Port Configuration button to display the STP Configuration settings for each port see the...

Страница 60: ...cification 5 6 SNMP Button This button displays the SNMP Simple Network Management Protocol page as shown below See SNMP Configuration in Chapter 3 for an explanation of SNMP settings 5 7 Addr Address...

Страница 61: ...ivity status and the VLAN segment for the devices connected to a particular port click the port s number in the top table Use the Search boxes to search for either an IP or MAC address on the IntraCor...

Страница 62: ...lected VLAN click the Ports button 5 8 1 Port Configuration Clicking the Ports button in the VLAN Groups page opens the VLAN Port Selection page as shown below The page shows the ports of the unit The...

Страница 63: ...ayed as shown below Enter or change the basic attributes then click OK Removing a VLAN To remove a VLAN from the current switch click Remove in the VLAN Group Configuration dialog box This removes the...

Страница 64: ...rt to Current VLAN 2 Click on a port to change its state For Add Delete Port Members clicking on a darkened port adds it to the VLAN while clicking on a VLAN member deletes it The status of the port o...

Страница 65: ...n opens the Security page which provides a summary of the security of each port on each switch as shown below The configuration pages for individual ports are accessed by clicking on the associated bl...

Страница 66: ...hich if the trap is enabled displays a record of duplicate IP Addresses detected The Log shows the MAC address of the device that is the original or rightful owner of the IP address and the MAC addres...

Страница 67: ...terface MIB Definitions of Managed Objects for the Ethernet like Interface Types RFC 1643 3 Bridge MIB Definitions of Managed Objects for Bridges RFC 1493 4 RMON MIB Remote Network Monitoring Manageme...

Страница 68: ...re unique all the way to the end of the path 6 4 1 Name Space Path The name space path is used by the SNMP protocol to define the piece of data that the manager wants There are three main name space p...

Страница 69: ...hat describe the bridge s function as a transparent bridge The dot1dStatic group This group allows the creation and management of static entries in the bridge s forwarding table The switch supports th...

Страница 70: ...ization 7 1 1 Port Based VLANs Port based VLANs are the simplest of many VLAN approaches others are based on MAC addresses protocol type and higher layers that are not currently supported by the IEEE...

Страница 71: ...col Data Units BPDUs The information exchanged in the BPDUs allows the bridges on the network to do the following Elect a single bridge to be the root bridge Calculate the shortest path from each brid...

Страница 72: ...t port The default value is 128 and the value range is 0 255 Port Path Cost Port path cost is the spanning tree parameter that assigns a cost factor to each port The lower the assigned port path cost...

Страница 73: ...big a job if the network manager had to configure every connection manually To make configuration as automatic as possible the IEEE has defined standards so that most connections can be automatically...

Страница 74: ...or on one side of the link connected to the Receive Rx connector on the other side of the link Cannot establish communication to another device switch router workstation etc Make sure the Link LED for...

Страница 75: ...ime maximum age and forward delay Ports are individually configurable for STP parameters priority path cost SNMP Separate read and write communities and trap authentication Four configurable trap rece...

Страница 76: ...000BaseT over Category 5 UTP 4 pairs maximum distance 328 feet 100 meters IEEE 802 3u 100BaseTX over Category 5 UTP 2 pairs maximum distance 328 feet 100 meters IEEE 802 3 10BaseT over Category 3 UTP...

Страница 77: ...ealer or local power company 9 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a s...

Страница 78: ...m compatibility with other vendors products or future compatibility due to third party software or driver updates 7 TO THE EXTENT ALLOWED BY LOCAL LAW THE ABOVE WARRANTIES ARE EXCLUSIVE AND NO OTHER W...

Страница 79: ...e available from Radio Shack s website catalog 26 117 The setting is 9600 N81 The table below lists the pin outs Pin Number Signal Name 1 CD Carrier Detect 2 RD Receive Data 3 TD Transmit Data 4 DTR D...

Страница 80: ...gistration Before calling Asant Technical Support please register your switch online at www asante com support registration html By doing so you ll be entitled to special offers up to date information...

Страница 81: ...rap Configuration Menu type b in the Configuration Menu If the Load Mode is set to Local a screen similar to Figure 3 6 appears When switch is powered on it loads its software via one of two methods l...

Страница 82: ...Set Remote Boot Retry Count a Toggle Boot Bank o Commence Bootstrap Sequence q Return to previous menu Command 3 Type b to set the Boot Mode to BootP TFTP or type t to set Boot Mode to TFTP only If yo...