Asanté FriendlyNET FS4016P Installation Guide

Page 5

 

Using the Uplink connection 

 

To connect a switch or hub, note the following:

1.

One normal/uplink push button on the front panel allows users to select to connect to a PC or a 
hub/switch.  The default setting is in the Normal (MDI-X) position, i.e. the out position. The port is 
configured to connect with a PC. When the push button is pressed in (MDI), it allows users to con-
nect with a hub or a switch using straight-through twisted pair cable.

 

 

  Use a straight-through cable to connect uplink port or use a crossover cable to 

connect to any port except uplink port. (Do not connect both uplink ports 
together, and do not use a crossover cable to connect with the uplink port).

Normal/Uplink

8

16

9

16

8

16

Normal/Uplink

9

Normal/Uplink

8

16

9

16

8

16

Normal/Uplink

9

Push button in the

OUT position

Push button in the

IN position

 

FS40016P.fm  Page 5  Tuesday, March 16, 1999  5:53 PM

Содержание FriendlyNET FS4016P

Страница 1: ...ections to servers or can link 10Mbps workgroups to a 100Mbps Fast Ethernet net work backbone For straight through 10Base T 100Base TX connection to servers and workstations the switch sup ports full duplex connection effectively doubling the total throughput on individual links The switch s store and forward switching architecture forwards packets to their destination with a minimum of delay The ...

Страница 2: ...diately Installation The Asanté FriendlyNET FS4016P switch is easy to install and requires no special training You should however read the following instructions carefully before proceeding to install your switch The diagram below shows the layout of the front and rear panels Front Rear Panel of the Asanté FriendlyNET FS4016P Normal Uplink 1 8 9 1 16 9 9 16 8 16 Normal Uplink 9 Full Auto 8 1 16 9 ...

Страница 3: ...ts can be connected to or disconnected from the switch while the power is on Plugging in or removing network cables while your switch is operating will not interrupt the operation of the switch When placing your switch you need to avoid dusty locations and electromag netically noisy areas Desktop Placement You can place the switch on a table In this case use the four self adhesive feet which are p...

Страница 4: ...traight through cable between the switch and the station does not exceed 100 meters including all patch cables and cross connect wires 2 Connect one end of the cable to the RJ 45 connector on the switch and the other end to the sta tion 5 4 3 2 1 10Mbps workstation 100Mbps workstation 10Mbps workstation 100Mbps workstation 100Mbps workstation Connection cable may be up to 100 meters long FS40016P ...

Страница 5: ...en the push button is pressed in MDI it allows users to con nect with a hub or a switch using straight through twisted pair cable Use a straight through cable to connect uplink port or use a crossover cable to connect to any port except uplink port Do not connect both uplink ports together and do not use a crossover cable to connect with the uplink port Normal Uplink 8 16 9 16 8 16 Normal Uplink 9...

Страница 6: ...tch is powered on and ready for use OFF The switch is powered off Please check the following issues Make sure the power adapter is properly inserted into the power connector on the switch Determine whether or not the power adapter is func tional by plugging another device into the receptacle FS40016P fm Page 6 Tuesday March 16 1999 5 53 PM ...

Страница 7: ... is being received Yellow A 100Mbps link is established on the port Blinking Yellow A 100Mbps link is established and traf fic is being received Table 3 Full Duplex Collision Color Status Off There is no link Or the port is operat ing in half duplex mode Yellow The port is operating in full duplex mode Blinking Yellow The port is in the half duplex mode and a collision has occured FS40016P fm Page...

Страница 8: ...t may be manually config ured for full duplex operation using the DIP switches on the rear panel of the switch If a port is configured for full duplex operation you must ensure that the link partner is also set for full duplex Don t connect a hub to a port that is set for full duplex Full Auto 8 1 16 9 FS40016P fm Page 8 Tuesday March 16 1999 5 53 PM ...

Страница 9: ...o mounting brackets and six screws for mounting into a 19 rack Rack mounting in a 19 rack 1 Locate the mounting bracket over the mounting holes on each side of the switch 2 Insert the screw through the bracket and into the bracket mounting holes in the switch 3 Insert the unit into the 19 inch rack FS40016P fm Page 9 Tuesday March 16 1999 5 53 PM ...

Страница 10: ... UTP STP Port 16 N WAY ports Uplink port Port 16 Cabling UTP STP Category 3 4 5 100 ohm impedance Input voltage 100 240 Vac 50 60Hz Operating temperature 0 40 C 32 122 F Operating humidity 10 95 Certification FCC Class A and CE Class A Dimensions 330mm W x 207mm D x 43mm H 13 W x8 1 D x 1 6 H FS40016P fm Page 10 Tuesday March 16 1999 5 53 PM ...

Страница 11: ...ort To contact Asanté Technical Support Telephone 800 622 7464 Fax 801 566 3787 E mail support asante com World Wide Web Site http www asante com Technical Support Hours 6 00 a m to 5 00 p m Pacific Standard Time USA Monday Friday FS40016P fm Page 11 Tuesday March 16 1999 5 53 PM ...

Страница 12: ...FAX 801 566 3787 e mail address sales asante com World Wide Web site http www asante com 1999 Asanté Technologies Inc Asanté is a trademark of Asanté Technologies Inc All brand names and products are trademarks or registered trademarks of their respective holders March 1999 Rev A FS40016P fm Page 12 Tuesday March 16 1999 5 53 PM ...

Отзывы: