ASAIR AHT10 Скачать руководство пользователя страница 10

10/10

www.aosong.com      Guangzhou Aosong Electronics Co.,Ltd.        Tel

:

400

-

630

-

5378

  

     Versior

:

V1

.

1  

Version

Date

Version

Page

Alteration

Initial Version

This manual is likely to change sometime without prior notice.

Attention

Warning of personal injury

ESD Protection

If the Buyer intends to purchase or use the Aosong 
products without any application license and 
authorization, the buyer shall bear all compensation 
for personal injury and death resulting therefrom, and 
shall not claim for compensation including various 
costs, compensation fees, lawyers, etc. Expenses and 
so on with the managers and employees of Aosong 
Company, as well as subsidiaries, agents, distributors, 
etc. 

ASAIR

®

2018

/

11

2018

/

12

V1.1

V1.0

1-10

1-10

Newly added protocol description and instruction parameters.

Do not apply this product to safety protection devices 
or emergency stop equipment, as well as any other 
applications that may cause personal injury due to 
the failure of the product. This product cannot be 
used unless there is a special purpose or with an 
authorization to use it. Please refer to the product 
data sheet and Application guide before installing, 
processing, using or maintaining the product. Failure 
to comply with this recommendation may result in 
death and serious bodily injury.

Due to the inherent component design, it is sensitive 
to static electricity. In order to prevent the damage 
and the reduction of the product's performance caused 
by static electricity, the necessary anti-static measures 
should be taken when applying this product.

Quality Assurance

Our company provides 12-month (1-year) quality 
assurance for buyers of its products (calculated from the
date of delivery) based on the technical specifications in 
the data manual of the product published by Aosong. If 
the product is found to be defective under warranty, our 
company will provide free maintenance or replacement. 
Users need to satisfy the following conditions: 

● Notify our company in writing within 14 days after the 
  defect is found
● The defect of this product will help to find out the 
  deficiency in design, material and technology of our 
  product.
● The product should be sent back to our company at 
  the buyer's expense.
● The product should be under warranty.

Our company is only responsible for the defective products 
which are used in the occasions that meet the technical 
requirements of the product. Our company makes no 
warranties or written representations regarding the use of 
its products in special application occasions.

At the same time, the company does not make any 
commitment to the reliability of the products applied to 
products or circuits.

 ©

Copyright 2018 , ASAIR® .

AHT10  Technical Manual

Содержание AHT10

Страница 1: ...ach sensor is calibrated and tested with product batch number printed on the surface of the product Due to the improvement and miniaturization of the sensor its cost effective ratio is higher and nall...

Страница 2: ...Package Quantity AHT10 4000PCS Roll Tape package Package Information 1 This precision is the test precision of the sensor with 3 3V voltage at 25 excluding hysteresis and nonlinearity and only suitab...

Страница 3: ...ing scope as shown in Figure 4 Long term exposure to abnormal scope especially when humidity 80 may lead to temporary signal drift drift 3 RH after 60 hours When the sensor is restored to normal worki...

Страница 4: ...o use no cleaning type 3 solders tin 9 and to purify it with nitrogen during re ux ASAIR 4 10 2 1 Welding Speci cation www aosong com Guangzhou Aosong Electronics Co Ltd Tel 400 630 5378 Versior V1 1...

Страница 5: ...be stored in the original package including sealed ESD bag and meet the following conditions temperature range 10 50 0 85 in a limited time humidity 20 60 RH no ESD packaged sensor For sensors that h...

Страница 6: ...frequency 3 3 Serial data SDA SDA pins are used for data input and output of sensors When sending commands to sensors SDA is valid at the rising edge of serial clock SCL and SDA must remain stable whe...

Страница 7: ...for sample reference 5 1 Start Sensor Step 1 Make the sensor power on with selected voltage of VDD power supply voltage ranging from 1 8 V to 3 6 V When the sensor is powered on it takes 20 millisecon...

Страница 8: ...nt data Read temperature and humidity data Trigger measurement 0xAC humidity data humidity temperature temperature data temperature data This command see Table 9 is used to restart the sensor system w...

Страница 9: ...erature and humidity sensor Date YYYY MM DD 5 0 1 8 1 2 1 0 Batch XXXXXX AHT10 ASAIR XXXXXX Qty 4000PCS Model AHT10 All AHT10 sensors have laser labels on their surfaces See Figure 18 AHT10 is packed...

Страница 10: ...sult in death and serious bodily injury Due to the inherent component design it is sensitive to static electricity In order to prevent the damage and the reduction of the product s performance caused...