[AKD55X4-B]
<KM119202>
2015/09
2.
Click the “Write” button on right side of Addr 01H register.
Figure 7-2. Register set window
3.
Input dummy command settings and click “OK” to write dummy command to AK55X4/X2.
The following No Ack error message will pop up. Click “OK”.
Figure 7-3. No ack message window
4.
Input registers accordingly into dialog box to evaluate AK55X4/X2.
Button Functions
1. [Port Reset]
: Set up USB interface board (AKDUSBIF-B).
2. [Write Default] : Initialize all register setting.
3. [All Write]
: Write all registers currently displayed.
4. [All Read]
: Read all register setting.
5. [Save]
: Save the current register setting to .akr file.
6. [Load]
: Load register setting from saved .akr file.
7. [All Reg Write] : Opens “All Register Write” dialog box. (see Dialog boxes below)
8. [Data R/W]
: Opens “Data Read/Write” dialog box . (see Dialog boxes below)
9. [Read]
: Read and display current register setting in register window (on right side of main window).
Different from [All Read] as it does not reflect to the register map.
10. [Close]
: Close Control Software window.
- 25-