AVHPRS                                                                                                                                                                                                                                                                                       

 

       

 

         

Warning

 

Follow all product specification and warnings when using these products. 

 

Our company does not guarantee every application, although we are constantly making every effort 
to improve the quality and reliability of these products. The products used in equipment could cause 
serious  physical  damage  or  property  damage,  if  appropriate  and  safe  design  procedures  are  not 
followed. We take no responsibility for these products if there was no written agreement regarding 
the compatibility of the product with the application.

 

 

Please carry it out understanding instructions written in this book or a technical documentation if you 
need assistance on product specification, installation/plumbing, operation and maintenance. 

 

Cautions for design of piping and product selection 

 

Warning

 

1.  Please  choose  from  the  products  within  the  specification  range  of  the  working  conditions  such  as 

medium, working temperature/pressure and so on. 

2. Confirm the fluid compatibility with the wetted part of the products in the "Suitability List on Medium" in 

the  latest  Dymatrix  general  catalogue  (AV-V-029-EJ).  (Parts  may  be  damaged  by  a  kind  of  a 
medium.) Consult us on any medium, which is not listed in "Suitability List on Medium".Moreover, if 
you intend to use it with compressed air or gas (such as air, nitrogen, ozone, or other gas), we do not 
assume product liability of the Product. 

3. If there are foreign substances in a fluid, please install a filter. 

  (

It would make the valve unable to seal.

 

4. Please contact us, when use for the fluid containing the crystalline substance. 

  (

It would make the valve unable to seal.

 

5. Use the products within the range of working pressure shown in this user's manual. 
6. Use the products within the range of working temperature shown in this user's manual. 
7. Use the products within the range of atmospheric temperature shown in this user's manual. Please 

use the products upon confirmation of compatibility with material and atmosphere. Do not adhere any 
fluid to the external surface of product. 

8. Please refers to the latest instruction manual issued by each fitting maker, and attach the fitting as 

instructed. 

9.  When  preparing  the  bypath  piping,  avoid  making  the  circuit  a  sealed  loop,  which  would  cause 

breakage of the piping material. 

10. Secure the maintenance space. 

 

Cautions for installation and plumbing 

 

Warning

 

1. Read in this user's manual (IOM-Manual) carefully prior to installation/plumbing. 
2. Flush the piping completely and make sure that there is no foreign substances in the piping prior to 

installation/plumbing of our product into it. 

3. Confirm the leak inspection is carried out correctly after the installation/plumbing. 
4. Make sure that the valves are free of tensile/compression/bending stresses. 
5. Do not apply excessive load on valve. 
6. Confirm the flow direction of the valve matches the flow direction indication on the body. 
7. Keep the valve away from excessive heat or fire. (It can be deformed or destroyed.) 
8. Do not use the products in a place where they may become submerged in water.

 

 

Caution

 

1. Do not give any impact or drop the products. 
2. Avoid scratching the products with any sharp object. 

 

 

Содержание Dymatrix AVHPRS

Страница 1: ...Serial No DTS168 01 General cautions Part names Specifications How to select types Dimension How to operate Technical data How to installation How to piping Check items Causes of defects and how to co...

Страница 2: ...User s Manual AVHPRS 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Страница 3: ...User s Manual AVHPRS 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Страница 4: ...alve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Страница 5: ...nding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to...

Страница 6: ...inlet pressure is from minimum working pressure to 0 3MPa and there is no back pressure change Proof Pressure 0 5 72 5psi Working Pressure range 0 03 0 3 Pilot pressure 4 35 43 5psi Max setting Press...

Страница 7: ...Pillar Fitting Flowell 60 series Flowell 20 series 2 6 S 3 10 T AVHPR 50 50 Type Connection tubing size 60 60 F K EPDM F 2 Viflon F 6190 Karlez 6190 FKM E T Connection How to select types Ordering co...

Страница 8: ...56 inch mm S 89 55 inch mm 3 88 inch F 106 58 inch mm T 110 inch 105 mm 102 inch 138 mm 134 inch mm S 113 71 inch mm 3 110 inch F 122 71 inch mm T 102 inch 113 73 mm 110 73 inch 138 72 mm 134 72 inch...

Страница 9: ...diameter tolerance Connection tubing size 06 10 12 Super Type Pillar fitting 6 35x3 95 9 53x6 33 12 7x9 5 Super 300 Type Pillar fitting 12 70x9 53 Flowell 60 series Flare Type Tube Unit mm Connection...

Страница 10: ...ctronic Pneumatic regulator 7 Please do not use the regulator without the exhaust function The valve may not operate precisely 8 Please leave the pilot air pressure off in case the valve is not used f...

Страница 11: ...rence Flow Range Flow rate Downstream pressure Pilot pressure Flow rate Pilot pressure Downstream pressure The data shown here is the experimental values and the reference values Upstream pressure Dow...

Страница 12: ...60 Upstream pressure Downstream pressure Upstream pressure Flow rate Flow rate Downstream pressure Pilot pressure Flow rate Pilot pressure Downstream pressure Orifice Reference Flow Range The data sho...

Страница 13: ...mensions see Dimension Flow direction Always flow medium in a specified direction Please check the arrow sticker on the side of the body before mounting 0 4 0 6N m Be careful about the screw length Fa...

Страница 14: ...User s Manual AVHPRS 13 How to piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar fitting Super 300 Type Pillar fitting Flare Type...

Страница 15: ...he inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness o...

Страница 16: ...n Plastic air couplings Sealing tape 1 0 2 0 4 N m 2 3 1 Always use plastic couplings and tighten them to a torque between 0 2 and 0 4 N Overtightening them with a spanner or the like may break the pr...

Страница 17: ...mends you to check them at least once a year When finding any problem or trouble call us Check points Check items Actuator Appearance flaw crack distortion discoloration Leakage of the pilot air Do no...

Страница 18: ...he downstream side of the orifice Check the piping The upstream pressure is low Check the operating conditions Flaw in the diaphragm or body Replace the valve Foreign matter is caught in the valve Lea...

Страница 19: ...ose of product improvement 2020 12 v01 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno...