Specifications

Input Impedance

Mic 4K Ohms Balanced
Line 22K Ohms Unbalanced

Input Gain

Microphone Variable 10 dB to 50 dB with rear trim control
Mic / Line switch -20dB

Output Level

( Max)   +21dB

AGC Threshold

–40 to 0 dB

AGC Output Gain

–20 to +20 dB

Phantom Power:

+48VDC switchable on all Microphone Inputs

Output Signal/Noise

-90dB A weighted, all inputs @ Unity, Master @ Unity

Dynamic Range

115dB

Master Output EQ

Low 100Hz 15dBCut/Boost

Mid 800HZ 15dB Cut/Boost Bell, Broad Q
High 10KHz 15dBCut/Boost

Master Outputs

Electronically Balanced XLR 300 ohms Line Level Balanced
Output Connectors Male XLR: Pin 1 Ground, Pin 2 +, Pin 3 –

Frequency Response

20Hz-20 KHz ± 1dB

Distortion (@ unity gain

Below  0 .01%, 100 Hz to 10KHz

Input Connector Type

Mic/Line - Amphenol Female XLR
Hi Z Input - Phono (RCA type)

Output Connector Type

Amphenol Male XLR

Recording Output Connector Type 

Amphenol Male XLR

Complete online documentation is available on the ARX website:

www.arx.com.au/unimix.htm

Specific queries can be emailed to the factory at 

[email protected]

ARX® is a Registered Trade Mark of ARX Systems Pty Ltd. MSX48™ is a

trade mark or ARX Systems Pty Ltd. Any other names and trademarks are

used for information purposes only, and no other intent is either expressed

or implied

This symbol indicates that a Slow Blow
fuse is used in this equipment. Replace
with same type and value only

This symbol is intended to alert you to
the presence of uninsulated dangerous
voltage within the product's enclosure

that may be of sufficient magnitude to
constitute a risk of electric shock.

This symbol is intended to alert you to
the presence of important operating
instructions contained in this owner's

manual

WARNING SYMBOLS USED

ON THIS EQUIPMENT

IMPORTANT 

- PLEASE READ THIS FIRST

THIS IS A DUAL VOLTAGE UNIT. IT IS ESSENTIAL THAT YOU CHECK THAT THE VOLTAGE ON

THE FUSEHOLDER COVER BELOW THE AC CONNECTOR ON THE REAR OF THE CHASSIS IS

SET CORRECTLY BEFORE CONNECTING IT TO AC POWER.

To change, pull fuseholder out and rotate 180

o

, then push in again. Do not insert power

cable into unit until voltage has been correctly set. Do not connect power cable to AC
power until voltage has been correctly set

THIS IS SET FOR 100 V

AC TO 120 V AC

OPERATION

THIS IS SET FOR 220 V

AC TO 240 V AC

OPERATION

Complies with 89/336/EEC EMC Di-

rective, amended by 92/31/EEC and

93/68/EEC; meets the following

standards:EN 55013 : 1990, Sections

3.2 and 3.5, EN 55020 : 1988, Sec-

tions 4.3, 5.4, 6.2, 7.0, 8.0., and EN

60950 : 1994 Low Voltage Directive
Complies with Australian Standard AS/

N25 1053

Our policy is one of continuous im-

provement, and therefore designs may

change without notice. However, un-

less otherwise stated, specifications

will always equal or exceed those pre-

viously given.