ARX Quadcomp II Скачать руководство пользователя страница 2

Quadcomp ®

II

  Owner's Manual   v 4.0 CE ©2010 ARX®

Quadcomp ®

II

  Owner's Manual   v 4.0 CE ©2010 ARX®

2

7

Specifications

Input Impedance

Balanced   20 Kohms
Unbalanced 10 Kohms

Input Headroom

+ 20 dB

CMRR

>50 dB, 20 Hx - 20 KHz

Output Impedance

Balanced   300 ohms
Unbalanced 150 ohms

Output Level (Max)

+ 22 dB

Attack and Release Times

Program dependent

Frequency Response

20 Hz to 20 KHz, ± 0.5 dB

Signal to Noise ratio

-93 dB Unweighted
-961 dB ‘A’ weighted

Distortion

.0054% THD @ 0 dB,1KHz

Dynamic Range

113 dB

Variable Gain Cell

Full Class A VCA, with true 2 pole
averaging RMS/DC converter

Power Requirements

100/120 V AC 220/240 V AC
50-60 Hz, 8 Watts, (8 VA)

Weight

5 lbs/2.2Kg

Dimensions

19"W x 1¾H x 6"D
482 x 44 x 155mm

Input Connector type

Balanced XLR

Output Connector type

Balanced XLR

Sidechain Insert Connector

Jack (TRS)

This symbol indicates that a Slow Blow
fuse is used in this equipment. Replace
with same type and value only

This symbol is intended to alert you to
the presence of uninsulated dangerous
voltage within the product's enclosure

that may be of sufficient magnitude to
constitute a risk of electric shock.

This symbol is intended to alert you to

the presence of important operating
instructions contained in this owner's

manual

WARNING SYMBOLS USED

ON THIS EQUIPMENT

IMPORTANT 

- PLEASE READ THIS FIRST

THIS IS A DUAL VOLTAGE UNIT. IT IS ESSENTIAL THAT YOU CHECK THAT THE VOLTAGE ON

THE FUSEHOLDER COVER BELOW THE AC CONNECTOR ON THE REAR OF THE CHASSIS IS

SET CORRECTLY BEFORE CONNECTING IT TO AC POWER.

To change, pull fuseholder out and rotate 180

o

, then push in again. Do not insert power

cable into unit until voltage has been correctly set. Do not connect power cable to AC
power until voltage has been correctly set

THIS IS SET FOR 100 V

AC TO 120 V AC

OPERATION

THIS IS SET FOR 220 V

AC TO 240 V AC

OPERATION

Complies with 89/336/EEC EMC Di-

rective, amended by 92/31/EEC and
93/68/EEC; meets the following
standards:EN 55013 : 1990, Sections

3.2 and 3.5, EN 55020 : 1988, Sections
4.3, 5.4, 6.2, 7.0, 8.0., and EN 60950 :
1994 Low Voltage Directive
Complies with Australian Standard AS/
N25 1053

Our policy is one of continuous im-
provement, and therefore designs may

change without notice. However, un-
less otherwise stated, specifications
will always equal or exceed those pre-

viously given.

Complete online documentation is available on the ARX website:

www.arx.com.au/Quadcomp2.htm

Specific queries can be emailed to the factory at 

[email protected]

ARX® is a Registered Trade Mark of ARX Systems Pty Ltd. MIXXMas-

ter™ is a trade mark or ARX Systems Pty Ltd. Any other names and

trademarks are used for information purposes only, and no other intent is

expressed or implied

Отзывы: