Specifications

Channels 1 - 6

Input Impedance

2 MegOhm

Input Headroom

+21 dB

Output Signal/Noise

-98 dB Unweighted
-104 dB A weighted
@ unity gain

Output Level (Max)

+26 dB

Dynamic Range

124 dB

Frequency Response

20 Hz to 20 KHz  -0.5dB

Distortion (@ unity gain)

100 Hz      .004%
1 KHz       .003%
10 KHz      .005%

Input/OutputConnector Type

Jack

Balanced Output Type

XLR

Master Section

Output Signal/Noise

All Inputs at unity, Master at unity
-90 dB unweighted
-96 dB A weighted

Output Level (Max)

+26 dB

Output Impedance

600 ohms

Distortion

.006% @ 1 KHz, unity gain

Output Connector Type

Jack (on front) and XLR (on rear)

Splitter Input

Maximum Level

+20 dB

Input Impedance

Line - 20 Kohms Balanced
Mic - 5 KOhms Balanced

Input Connector Type

XLR

Power Requirements

1

00/110 or 220/240V AC 50/60 Hz
8 Watts (8 VA)

Weight

5 lb/2.2 Kg

Dimensions

19"W x 1¾"H x 6"D
482 x 44 x 155 mm

This symbol indicates that a Slow Blow

fuse is used in this equipment. Replace
with same type and value only

This symbol is intended to alert you to

the presence of uninsulated dangerous
voltage within the product's enclosure
that may be of sufficient magnitude to

constitute a risk of electric shock.

This symbol is intended to alert you to

the presence of important operating
instructions contained in this owner's
manual

WARNING SYMBOLS USED

ON THIS EQUIPMENT

IMPORTANT 

- PLEASE READ THIS FIRST

THIS IS A DUAL VOLTAGE UNIT. IT IS ESSENTIAL THAT YOU CHECK THAT THE VOLTAGE ON

THE FUSEHOLDER COVER BELOW THE AC CONNECTOR ON THE REAR OF THE CHASSIS IS

SET CORRECTLY BEFORE CONNECTING IT TO AC POWER.

To change, pull fuseholder out and rotate 180

o

, then push in again. Do not insert power

cable into unit until voltage has been correctly set. Do not connect power cable to AC
power until voltage has been correctly set

THIS IS SET FOR 100 V

AC TO 120 V AC

OPERATION

THIS IS SET FOR 220 V

AC TO 240 V AC

OPERATION

Complies with 89/336/EEC EMC Di-
rective, amended by 92/31/EEC and

93/68/EEC; meets the following
standards:EN 55013 : 1990, Sections
3.2 and 3.5, EN 55020 : 1988, Sections

4.3, 5.4, 6.2, 7.0, 8.0., and EN 60950 :
1994 Low Voltage Directive
Complies with Australian Standard AS/

N25 1053

Our policy is one of continuous im-
provement, and therefore designs may
change without notice. However, un-

less otherwise stated, specifications
will always equal or exceed those pre-
viously given.

Complete online documentation is available on the ARX website:

www.arx.com.au/DI6sm.htm

Specific queries can be emailed to the factory at 

[email protected]

ARX® is a Registered Trade Mark of ARX Systems Pty Ltd. MIXXMas-

ter™ is a trade mark or ARX Systems Pty Ltd. Any other names and

trademarks are used for information purposes only, and no other intent is

expressed or implied

Отзывы: