Power Supply

Toroidal power transformer and Heavy duty diode bridge, to retain dynamic range under even
the heaviest load conditions.

Input Impedance

20 Kohms Balanced

Input Sensitivity

.775 Vrms (0 dB)

Input CMRR

@ 1KHz >70dB

l

nput Connector

1 x XLR ( Female) Pin 3-, Pin 2 +, Pin 1 Electronic Ground

Crossover Filter Type

Linkwitz Riley 24dB per Octave 4th Order

High Pass Filter

18dB per Octave 3rd Order 30Hz user adjustable

Thiele Small

LF EQ

0dB factory set user adju6dB 30Hz - 80Hz

HF EQ

Internally switchable: Flat or +6dB 10KHz

Output Power (RMS)

CP550

Both channels driven: 200 watts RMS into 8 ohms, 270
watts RMS into 4 ohms

CP850

Both channels driven: 300 watts RMS into 8 ohms, 400
watts RMS into 4 ohms

Distortion

THD @ 100Hz, 8 ohms 0.03%

THD @ 1KHz, 8 ohms  0.05%

Slew Rate

35V

u

S

Damping Factor

200:1

Protection Features

• Output switched thermal sensing

• Relay switched DC sensing

• Input/Output mute at turn on and off

• Variable speed fan assisted cooling

Output Connectors

Neutrik Speakons777

Metering

LED status indicators for Clip and Protection

Cooling

Front to back with ‘UltraFin’ heatsink and 2 x variable speed
thermo controlled DC fans

Construction

All steel chassis and front panel, with Lexan front and rear
print. Rear rack mount ears, front panel power switch, rear
panel low and high level controls

AC Power

Supplied ‘zone-specific’: 100/120/220/ 240V AC

Weight

CP550 10 Kg (22 lbs)

CP850 12 Kg (26 lbs)

Size

Standard 2 rack units high and 19" (482 mm) wide

Depth

16" (405mm)Add 25mm to depth behind front panel to allow for rear
rack mount ears and handles; add 25mm to depth before front panel
to allow for handles and controls

This symbol indicates that a Slow Blow fuse is used in this equip-

ment. Replace with same type and value only

This symbol is intended to alert you to the presence of uninsulated

dangerous voltage within the product's enclosure that may be of

sufficient magnitude to constitute a risk of electric shock.

This symbol is intended to alert you to the presence of important

operating instructions contained in this owner's manual

WARNING SYMBOLS USED ON THIS EQUIPMENT

IMPORTANT - 

This amplifier is designed

to be connected ONLY to the AC voltage

ticked       below

100 V AC, 50 - 60 Hz

120 V AC, 50 - 60 Hz

220-240 V AC, 50 - 60 Hz

240 V AC, 50 - 60 Hz

!

It is essential that you check that
this voltage is correct for your
area before connecting it to AC
power. Do not plug power cable
into AC power until voltage has
been checked. If incorrect, contact
your ARX distributor.

Your warranty does not cover
connecting the amplifier to the
wrong voltage AC power!

FUSE

These amplifiers have a removable AC power

lead that connects to an IEC connector (See

Picture at Left) with built in fuse. Replace fuse

with correct value as marked on the rear of the

amplifier

Complies with 89/336/EEC EMC Directive,
amended by 92/31/EEC and 93/68/EEC and
meets the following standards:EN 55013 : 1990,
Sections 3.2 and 3.5 EN 55020 : 1988, Sections
4.3, 5.4, 6.2, 7.0, 8.0.

Complies with Australian Standard AS/N25 1053