- Pump connections

Before connecting the motor to the pump, read 
this  instructions  manual  and  the  one  supplied 
with the pump or electric pump to wich the mo-
tor will be coupled.

Keep both manuals with care.

-Installing the motor in a well or tank

Follow  the  instructions  in  the  pump  or  electric 
pump brochure.

When  installing  the  electric  pump  vertically, 
make sure the motor does not rest on the bot-
tom of the well ot tank.

When  installing  the  electric  pump  horizontally, 
make sure the motore does not rest on the bot-
tom of the tank.

2.01 START-UP

Follow  the  instructions  in  the  pump  or  electric 
pump manual

-Electrical connections to the electric pump

Electrical  connections  may  only  be  performed 

I`HX\HSPÄLKPUZ[HSSLYPUJVTWSPHUJL^P[OJ\Y

-

rent regulations.
Make  sure  that  the  supply  voltage  and  fre-
quency are compatible with the electrical panel. 
The relative information is shown on the motor 

PKLU[PÄJH[PVUWSH[LHUKPU[OLKVJ\TLU[ZZ\W

-

plied with the panel. Provide suitable short cir-
cuit protection on the supply line.

Before proceeding, make sure that all the con-
nections  (even  if  they  are  potential-free9  are 
voltage-free.

Unles

ZV[OLY^PZLZWLJPÄLKPUSVJHSI`SH^Z[OL

Z\WWS`SPULT\Z[ILÄ[[LK^P[O!

- a short circuit protection device.

- a high sensitivity residual current circuit brea-
ker (30mA) for addictional protection from elec-

[YVJ\[PVUPUJHZLVMPULMÄJPLU[NYV\UKPUN

- a general switch with a contact aperture of at 
least 3 millimiters.
Ground the system in compliance with current 
regulations.

Single-phase version

Connect the electric pump to a supply line via 
a suitable electrical control panel containing the 
overload protection and the capacitor.

Refer to the wiring 

KPHNYHTPUÄN\YLHUK[OL

documentation supplied with the electrical pa-
nel.

Refer to the motor rating plate for the capacity 
of capacitor.

Install the electrical panel in a sheltred area.

Figure 2: Single-phase wiring diagram

Three-phase version

Connect the electrical pump to a supply line via 
a suitable electrical control panel.

Install the electrical panel in a sheltered area.

Refer  to  the  documentation  supplied  with  the 
electrical panel.

For  connections  to  any  external  control  follow 
the instructions supplied with these devices.

Содержание OP Series

Страница 1: ...SUBMERSIBLE MOTOR OP 4 OPERATING INSTRUCTION ...

Страница 2: ...hall have to be presented in writing within seven 7 days of receving the motor 1 01 WARRANTY The manufacturer guarantees its products for a period of twelve 12 months from the date of purchase This warranty is onlyexpressed in the repair or replacement free of charge of those parts that after careful examination by the manufacturer turn out to be defective War ranty excluding all liability for dir...

Страница 3: ...T00750 386 5 8 OPM01000 0 75 1 0 401 5 9 4 OPT01000 406 5 9 OPM01500 1 1 1 5 432 5 10 7 OPT01500 442 5 10 4 OPM02000 1 5 2 0 472 5 12 6 OPT02000 482 5 12 1 OPM03000 2 2 3 0 585 17 3 OPT03000 560 16 9 OPT04000 3 0 4 0 635 20 OPT05500 4 0 5 5 684 22 3 OPT07500 5 5 7 5 804 27 9 OPT10000 7 5 10 919 33 6 ...

Страница 4: ...ions Do not subject the equipment to work it could not reasonably support Operate only with good lighting in a safe po sition free from hindrances When handling the motor use suitable lifting Equipment in conformity with the safety regu lations and wear safety shoes and gloves Never handle the equipement by pulling in its power cable Use only cables of allowed lenght marked and with suitable cross...

Страница 5: ...OL PKLU PÄJH PVU WSH L VM OL TV tor the motor and pump shafts turn freely Motor powered by a frequency converter Only specially ordered motors can be powered with a frequency converter If the motor is combined with a frequency con verter downgrade power by 10 and make sure never exceed the rated input frequency of the motor To ensure the motor is properly cooled the mini T T H LY ÅV YH L H OL TPUP...

Страница 6: ...ion on the supply line Before proceeding make sure that all the con nections even if they are potential free9 are voltage free UnlesZ V OLY PZL ZWLJPÄLK PU SVJHS I SH Z OL Z WWS SPUL T Z IL Ä LK P O a short circuit protection device a high sensitivity residual current circuit brea ker 30mA for addictional protection from elec YVJ PVU PU JHZL VM PULMÄJPLU NYV UKPUN a general switch with a contact a...

Страница 7: ...enance sche dule should bear in mind that maintenance cycle depends on the conditions of use For any requirements please contact our Sales and Service Department 4 00 SPARE PARTS Always specify the exact type of motor and code when requesting our Sales and Assistan ce Service for technical information or spare parts Only use spare parts to replace faulty compo nents Unsuitable spare parts may caus...

Страница 8: ...Arven S r l Via Artigiani n 10 25030 Maclodio Brescia Italy Tel 39 030 9973973 Fax 39 030 9973975 e mail info arven it www Arven it 0940 ARV0005 00 Ed 04 2019_00 ...

Отзывы: