Connecting guidelines  

CONNECTING THE CONTROL MODULE

 

 

The  control  module  is  installed  on  the  board  of  navigation  tracker  Arnavi  Integral  3  by  point 

soldering to the main connector of the tracker as shown in picture 3.  

  

Picture 3. Navigation tracker Arnavi Integral 3 with the installed control module  

Connection of the control module to other trackers is carried out as follows:   

VCC point:

 +12V DC with battery. Connect to the power line of the tracker, which is constantly present 

v12V. 
At this point, the control module transmits signals to the blocking relay. To ensure reliable control, the 
relay and control module must be electrically connected via this wire. 

 

GND point:

 "MASS". Connect to the "GND" (minus) line of the tracker, which is connected to the 

negative terminal of the battery. 

 

Exit point:

 Connect to the tracker's "out" pin. 

 

CONNECTING THE BLOCKING RELAY  

Red wire:

 + 12V DC with battery. Connect to the battery or 

to the wire of the car, which is constantly present v12V. 

On this wire, the control module transmits signals to the blocking relay. To ensure reliable control, the 

relay and control module must be electrically connected via this wire 

Black wire:

 MASS. Connect to the negative terminal of the battery. 

 

Содержание ARNAVI PLC

Страница 1: ...Wireless relay PLC ARNAVI PLC User Manual Arusnavi LLC...

Страница 2: ...User Manual 1 0 Page 2 Contest General information 3 1 Technical specifications 4 2 Principle of operation and appearance of thedevice 5 Connecting guidelines 6 Warranty 8 Package contents 9...

Страница 3: ...of the security complex of the car The blocking relay has small dimensions and allows to mask it in a harness of regular wiring Functionality Digital communication with the relay on the power wire Com...

Страница 4: ...mm 32 x 27 5 x 4 Weight of blocking relay gram 15 Weight of control module gram 2 5 Voltage V 7 15 Current consumed by the control module mA 5 Maximum switching current blocking relay A 20 Working tem...

Страница 5: ...signal to the relay If the output of the tracker is closed to ground the relay is open If the output of the tracker is not closed to ground the relay is closed Thus there is a control short circuit b...

Страница 6: ...point the control module transmits signals to the blocking relay To ensure reliable control the relay and control module must be electrically connected via this wire GND point MASS Connect to the GND...

Страница 7: ...rcuit in the area of its rupture as shown in picture 4 It is possible to block any electrical circuit whose characteristics do not exceed the values specified in table 1 The connection diagram of the...

Страница 8: ...al malfunctions caused by ingestion of foreign objects insects liquids presence of chemical electrochemical electrostatic extreme thermal damage damage caused by non compliance with state standards of...

Страница 9: ...9 Package contents The package set of PLC relay is presented in the table 2 Table 2 package set Title Quantity Notes 1 Control module 1 2 Blocking relay 1 For further information please see the websi...

Отзывы: