12
| AP-85 Series Hardware Overview
Aruba AP-85 Outdoor Access Point Series
| Installation Guide
Figure 6
Serial Console Port Pin-Out
Communication settings for the serial console port are listed in
Table 1
.
z
AC PWR 90-228 V~, 500 mA: The AP can accept AC power at the limits specified on the unit. If the AP-85FX/LX is not
connected to a DC power source, the AP must be powered by an AC power source. An outdoor rated, three-wire, 8-foot
long AC power cable (wiring harness) is supplied with the unit. Some installation locations are in the scope and under
the authority of the National Electric Code (NEC or NFPA 70), and some are not, as indicated in Article 90.2. The NEC
applies where:
The product must be grounded reliably using the external screw, as shown in this installation guide, and not solely
depend on the ground provided in the power supply cord.
The power cord should be less than 15" long.
The plug for the power cord should be installed in a dry location, such as with the use of an NRTL listed receptacle
box with cover that is weatherproof with the power plug inserted into the receptacle (such as the MultiMac model
from Taymac Corp).
The NEC does not apply when:
The installation must follow all regulations and established practices that are applicable for the particular installation
environment.
For international outdoor use:
The product must be grounded reliably using the external screw, as shown in this installation guide, and not solely
depend on the ground provided in the power supply cord. Considerations should include selection of weatherproofing
means (IP67 or better), proper strain relieving for the power cord, and adherence to all applicable regulations and
local practices.
The plug for the power cord should be installed in a dry location, such as with the use of a suitable certified
receptacle box with a cover, which is weatherproof (IP67 or better) with the power plug inserted into the receptacle.
z
Grounding Point
.
Table 1
Console Terminal Settings
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
9600
8
None
1
None
!
CAUTION
It is important that the AP-85FX/LX be properly grounded; a grounding point is provided on the
bottom of the AP-85FX/LX model. The installer (trained service personnel) should ensure that
grounding is available and that the grounding meets applicable local and national electrical codes.
Serial
Console Port
1
2
3
4
5
6
7
8
TxD
GND
RxD
RJ-45 Female
Pin-Out
Direction
Input
Output
GND