Aruba 518 Series Ruggedized Access Point
| Installation Guide
9
Figure 6
Attaching the AP-270-MNT-ADP Adapter to the AP (Completed)
3. Once the AP-270-MNT-ADP adapter is attached to the AP, the AP can be installed on a wall or attached to a
pole using the AP-270-MNT-XX mount kits in
Grounding the Access Point
The grounding must be completed before powering up the access point. The grounding wire should be #8 AWG.
1. Peel the cover of one end of the grounding wire and place the bare grounding wire into the included
grounding lug, and press firmly with the crimping pliers.
2. Fasten the grounding lug to the grounding hole on the access point with the included M4 x6 screw.
Connecting the Ethernet Cable
To connect the Ethernet cable to the access point, perform the following steps using the Ethernet cable glands
that ship with your access point.
!
Failure to use the included Ethernet cable gland can lead to connectivity and POE issues.
The cable is not included and must be purchased separately. Purchase a suitable UV-resistant, outdoor rated,
CAT 5E or better RJ45 cable for use with the access point.