Gas installation must be made in accordance with AS5601;
Also refer to rangehood manufacturers recommendation.
Check gas presure, note the correct setting from the data
plate sealed inside the front appliance drawer *.
Stability bracket
WARNING:
In order to prevent accidental tipping of the
appliance, for example a child climbing onto the open oven
door, the stabilising means must be installed.
Note:
If the wall plug provided is not suitable for the wall
material please use an appropriate device to ensure secure
holding of the "screw" to the wall.
Installing the gas cooker:
(Flexible connection are NOT supplied with this appliance)
- An inlet manifold extension pipe must be fitted to the
appliance. Part supplied in the drawer of the appliance.
- Ensure that the pipe is connetted using the washer
provided and that the braket is screwed to the appliance
as shown in the diagram below.
- Fit the supplied pressure regulator (for Natural gas) using
the NG test piont adaptor and washer to the inlet manifold.
Ensure the arrow is pointing towards the appliance and
that pressure testpoint is accessible from the final
position.
- Push the cooker back and install the stabilizing chains.
- Connect the appliance inlet manifold to the consumer
piping outlet using only fixed piping. This final connection
is made when the product is pushed back into position by
access under the cooker.
The hose assembly
- Must comply with AS/NZS 1869 Class B or D,
- With 10 mm internal diameter and be kept as short as
possible (less than 1,2 m)
Fig. B
Fig. C
GAS CONNECTION
- It must not be kinked
- It must not be in contact with hot surfaces.
IT IS RECOMMENDED THAT A SERVICE TAP AND UNION BE
FITTED ADJACENT TO THE APPLIANCE INLET TO
FACILITATE FUTURE SERVICING.
5 burner models: set the burner pressure to 1kPa for Natural
Gas and 2.75kPa for U-LPG with the wok burner operating a
full rate'. For commissioning of the appliance with the
regulator for Natural Gas, the test point pressure should be
1.00kPa with all burners operating on HIGH.
Apply a manometer to the test nipple and reset the regulator
if necessary. Do not forget to replace the test nipple screw
and to leave the instructions book with the user.
VERY IMPORTANT FOR THE INSTALLER
Do not attempt to turn or stress threaded elbow of the
manifold: you risk damage to this part of the gas appliance
which may void the manufacturers warranty.
Before Leaving – Check all connections for gas leaks.
DO NOT use a naked flame for detecting leaks. Ignite all
burners to ensure correct operation of gas valves, burners
and ignition. Turn gas taps to low flame position and
observe stability of the flame.
When satisfied with the cooker, please instruct the user on
the correct method of operation.
In case the appliance fails to operate correctly after all
checks have been carried out, refer to the authorised
service provider in your area.
GAS CONVERSION AND ADJUSTMENT
When used with natural gas all burners have been preset at
our factory and further adjustment should not be
necessary. Conversion kits to other gases are available
from the place of purchase. Do not attempt to fit the
conversion kit yourself. Conversion to U-LPG gas should
only be carried out by an authorized technician.
GAS ADJUSTEMENTS
- change the injectors
- adjust the minimum flow
‘When conver ting from Natural Gas to U-LPG ensure that
the NG regulator is removed and replaced with the Test
Point Assembly. A gas regulator suitable for a supply
pressure of 2.75kPa should be part of the gas tank supply
and should be adjusted with the wok burner operating at
maximum.
REPLACEMENT OF THE INJECTORS
When required to operate on other gas replace the
injectors in accordance with information referred to in chart
below.
A test point fitting must be
installed between the piping and
the appliance for the pressure to
be checked to ensure it is
operating for ULPG at 2.75 kPa.
Be aware that the appliance has
two gas inlets (L/R). Before
performing the leakage test
select which side will be the
connection point and cap and
pressure test the side that will not
be used.
A test point fitting must be
installed between the piping and
the appliance for the pressure to
be checked to ensure it is
operating for NATURAL GAS at 1
kPa.
Be aware that the appliance has
two gas inlets (L/R). Before
performing the leakage test select
which side will be the connection
point and cap and pressure test
the side that will not be used.
Pressure regulator for natural
gas
Pressure tst point for ULPG
Wall Fixing
Note:refer to page 15 for installation on a plinth.
6
6
Содержание CAFG90X
Страница 1: ...CAFG90X CAFG91X CAFG91B OPERATION MANUAL APPLIANCES FOR LIVING...
Страница 21: ......