21
nnection type andthe power rating of the cooker.
!
All electrical work should be carried out by a suitably qualified and authorized electrician.
No alterations or willful changes in the electricity supply should be carried out.
The cooker is manufactured to work with three-phase alternating current (380-415V 3N~50
Hz). The voltage rating of the cooker heating elements is 220-240V. Adapting the cooker
to operate with one phase current is possible by appropriate bridging in the connection box
-
box according to the connection diagram below. The connection diagram is also found on t
he cover of the connection box. Remember that the connection wire should match the co-
The fixing line connected must be equipped with the all-pole disconnection device
provided by breakaway the contact under overvoltage category III according to the
the wiring rules.
Before connecting the cooker to the power
supply it is important to read the informatIion
on the data plate and the connection
diagram.
!
Remember to connect the safety circuit to
the connection box terminal marked with
.
The connection cable must be secured in a strain-relief clamp.For the connection leads,
the grounding wire must be longer than the other wires.
22
Complies with AS/NZS regulations EN 50304, AS/NZS60335-1,AS/NZS60335-2-6
standards.
Top/bottom heater(kW)
TYPE
Dimensions
(height/width/depth) cm
Oven
Temperature regulator
/
function mode switch
1/1
Guide levels (telescopic
in 3 levels-only
guides
5
T
op heater(kW)
G
rill heater(kW)
Oven illumination (W)
Rear heater(kW)
Function modes
Top/Grill/Fan
Rear heater/fan
(kW)
(kW)
(W)
Separate oven lighting
Fan(W)
Max. temperature
250
Electric connection
380-415V 3N ~ 50Hz
Nominal voltage of heaters
220-240V
Total connected power (kW)
Top oven (kW)
Hotplate total (kW)
W
eight (kg)
AFDE5470W
90/54/60
0,85
1.1
2.0
25
2.0
25
30
9.5
2.0
5.5
52
2.0
2.0
certain models)
Main oven (kW)
2.0
Oven total (kW)
4
For 220-240V earthed one-phase connection,
bridges connect 1-2-3 terminals and 4-5
terminals, safety wire to
For 380-415V/220-240V earthed two-phase
connection, bridges connect 2-3 terminals
and 4-5 terminals, safety wire to
For 380-415V/220-240V earthed three-phase
connection, bridges connect 4-5 terminals,
phases in succession 1,2 and 3, earth to 4-5,
safety wire to .