Artusi ACH935B Скачать руководство пользователя страница 7

5

User Manual ACH935B

17.Do not use non-fire-resistant materials instead of filters.
18.Keep the potentially dangerous packaging materials away from 
children.
19.Do not use your product without a filter, do not    remove filters 
when the product is operating.
20.In case of start of flames, cut off the power of the chimney fan and 
cooker.(Cut off the power by unplugging the device).
21.Turn off the hobs before you remove pots, pans, etc.
22.If the cleaning is not done periodically, your product may carry 
fire risk.
23.Cut off the power supply before any maintenance work. (Cut off 
the power by unplugging the device.)
24.For duct-out chimney hoods, use pipes with a diameter of 
150 mm or 120 mm. You should minimize the ducting distance with 
minimum bends.
25.Make sure your children do not play with the product. Do not let 
young children operate the product.
26.If the power cord is damaged, the damaged cord should be 
replaced by the manufacturer or its service agent or similarly 
specialised personnel in order to avoid a dangerous situation.
27.In case of start of flames, cut off the power of the chimney fan and 
cooker and cover the flame. Do not use water to extinguish the fire. 
28.WARNING: Install “MAX. 6 A” fuse for the extractor fan.

Содержание ACH935B

Страница 1: ...ACH935B OPERATION MANUAL APPLIANCES FOR LIVING...

Страница 2: ...will allow you to get the best results from using your appliance KEEP THE DOCUMENTATION OF THIS PRODUCT FOR FUTURE REFERENCE TO REGISTER YOUR PRODUCT WITH ARTUSI PLEASE FILL OUT THE WARRANTY CARD AT...

Страница 3: ...rmine the required clearance between the cooktop and the range hood always consult the installation manual for both the range hood and cooktop The required clearance is the greater of the distance spe...

Страница 4: ...chimney hood so that it maintains its quality just like the first day you bought it and serves you most efficiently NOTE This Instruction Manual has been prepared for a variety of models Some of the...

Страница 5: ...3 5 Installation of Inner Duct Mounting Bracket 8 4 Functions Of The Chimney Hood 8 4 1 Control Panel 8 4 2 Symbols Functions 9 5 Operating The Chimney Hood 9 5 1 In Ducted Use 9 5 2 Round Charcoal Fi...

Страница 6: ...ot touch the bulbs of your product if used for a long period of time The bulbs will be hot and may burn your hand 10 Kitchen chimneys are designed for domestic use If used for other purposes it may le...

Страница 7: ...ut off the power supply before any maintenance work Cut off the power by unplugging the device 24 For duct out chimney hoods use pipes with a diameter of 150 mm or 120 mm You should minimize the ducti...

Страница 8: ...User Manual ACH935B 2 INTRODUCTION AND TECHNICAL DRAWING OF THE CHIMNEY HOOD E F 1 Duct 2 Control panel 3 Filter 4 Lighting A 170 mm B 200 mm C 700 mm D 25 mm E 450 mm F 596 mm 896 mm 1 2 3 4 A B C D...

Страница 9: ...uminum Pipe Place the aluminum pipe on the plastic duct Place the other end of the pipe into the air outlet in the kitchen Figure 2 Twists and bends on the aluminum pipe may cause minimsing the air su...

Страница 10: ...m electric drill at a suitable height and place to fix the inner duct hanger plate onto the wall 6mm drywall anchors are nailed into those holes and inner duct mounting brackets are pinned down Figure...

Страница 11: ...d to an air outlet to send the air out In order to use your chimney hood efficiently make sure length of the pipe system between the chimney hood and the air outlet should be short Your product has be...

Страница 12: ...5 4 Installation Of Charcoal Filter Charcoal filters are used in the kitchens with no duct Charcoal filters are installed onto both sides of the fan as shown in Figure 7 by turning 10 degrees clock wi...

Страница 13: ...e procedures Metal filter should be cleaned once a month with hot soapy water or in the dishwasher if possible 60 C Remove the aluminum cartridge filter by pressing on the spring catches on the side D...

Страница 14: ...the windows in the kitchen leading to the outside should be kept closed 8 IF CHIMNEY HOOD DOES NOT WORK Before contacting the service make sure the product is plugged and the fuse in the electrical i...

Страница 15: ...ispose of the packaging materials together with the domestic or other wastes Take them to the packaging material collection points designated by the local authorities Chimney Hood does not work Light...

Страница 16: ...d and built in 12 months warranty products Freestanding Cookers Gas and Electric Models in 50cm 54cm and 60cm Widths Portable Appliances Benchtop Models and Portable Gas Models 2 What is not Covered b...

Страница 17: ...iances excludes indirect or consequential loss of any kind including without limitation loss of use of the artusi product and other than expressly provided for in these terms and conditions subject to...

Страница 18: ...e design specifications aesthetics and production techniques of its products As a result alterations to our products and designs take place continually Whilst every effort is made to produce informati...

Отзывы: