Using the battery: 

 

Connect  the  battery  discharge  cables  to  the  main  discharge 
poles (1 & 6 as indicated on the front cover photograph of this 
manual).  Switch  on  the  appliance  and  use  until  the  battery  is 
fully  discharged.  Depending  on  the  current  drained  in  the 
battery, the status LED indicates the following:  

 

Green 

Discharge

 

 If the discharge current is higher than 100 mA, 

the gas gauge LEDs light up 

 When the 

 signal on Specific 

PreAlarm

connector is ON, the battery is close to the end of 
discharge 

Orange

 

 

 

Regenerative charge 

 Battery receives a charge current higher than 

100 mA 

 When the 

 signal on Specific 

PreAlarm

connector is ON, the battery is close to 
regenerative charge limit (*) 

 When the regenerative charge is not allowed, 

the battery switches to Charge mode and may 
pulse the incoming current 

OFF 

Standby

, battery disconnected

 

 No voltage on main discharge poles 

 

 

(*):  only  when  the  regenerative  alarm  option  is  selected  For 
some  configurations,  the  battery  can  accept  a  regenerative 
charge. This function allows recovering energy from a motor or 
a reversible device powered by the Smart Module. 
 
It  is  recommended  to  start  to  use  the  battery  when  the  battery 
temperature is in the -10°C to +40°C range.  
 
It  is  possible  to  start  the  discharge  from  -20°C  to  +60°C 
occasionally. However the service life will be reduced by using 
the battery at high temperatures. 

Содержание Smart Module

Страница 1: ...Smart Module User Manual Date September 2016...

Страница 2: ...2 1 Main discharge pole 2 Fuses cover 3 Specific connector charge and communication 4 Gas Gauge LEDs push button 5 Status LED 6 Main discharge pole 1 6 5 2 3 4...

Страница 3: ...not be transferred to the battery Connect the CCPS to the Smart Module Connect the CCPS to the mains The Smart Module status LED will be orange 3 Charge the battery until a green fixed status LED is d...

Страница 4: ...the battery Orange Green Balancing charge Battery already operational more than 95 of capacity charged Current is reduced to perform the balancing of all the cells within the battery depending on thei...

Страница 5: ...mA When the signal on Specific PreAlarm connector is ON the battery is close to regenerative charge limit When the regenerative charge is not allowed the battery switches to Charge mode and may pulse...

Страница 6: ...pty and will be able to discharge again after cooling down below 55 C The battery goes in sleep mode after a long rest To wake up the battery Press the push button OR connect a charger OR use the Key...

Страница 7: ...Defect detected Contact your reseller or have a look at our FAQ list page 12 to see which maintenance actions could be realized Storage recommendations It is recommended to always store the battery co...

Страница 8: ...Status LED 80 100 100 80 80 50 50 30 30 10 10 0 Battery Empty During use to keep the accuracy of the gas gauge it is necessary to regularly fully discharge the battery according to the following proc...

Страница 9: ...check the state of health of the battery depress the push button for 2 seconds The 5 level display corresponds to the following state of health Battery state of health Status LED 0 10 Status LED 10 30...

Страница 10: ...o fire Warning If any leakage of electrolyte occurs stop using the battery immediately Electrolyte is corrosive to some metals If electrolyte comes in contact with your skin or clothes immediately was...

Страница 11: ...TO fuse 15A for charge and 40A Only for VH module for discharge is required Use a fuse 30A for a VHT Smart Module For 36 V batteries a 58V rated fuse 15A for charge and 40A Only for VH module for disc...

Страница 12: ...ry went up to 65 C The Status LED is OFF The battery is hot and when the gas gauge button is pressed this results in lighting of the gas gauge LED Wait for the battery to cool down The battery will di...

Страница 13: ...e THE BATTERY DOES NOT GO TO TRICKLE CHARGE STATUS LED GREEN Possible causes Actions The battery is brand new The duration of the balancing charge is set to 48 hours during the assembly process and in...

Страница 14: ...ge of the battery until the status LED lights up in green Then discharge once completely until blinking of gas gauge low level LED 0 10 If the shift between gas gauge capacity and cell capacity is gre...

Страница 15: ...15 PERSONAL NOTES...

Страница 16: ...7 Published By ARTS Energy Information in this document is subject to change without notice and becomes contractual only after written confirmation by ARTS Energy __________________________ ARTS Energ...

Страница 17: ...17 www arts energy com...

Отзывы: