8.

 

Systems Requirements 

 

8.1.

 

Recommended Specifications 

Host Controller 

 

This camera is applicable to USB 3.0. 

 

Connecting to USB 2.0 host controller may cause low-speed or failure to function properly.   

CPU 

 

The driver of this camera is applicable to 

computer architecture

 

x86

  or 

amd64

.   

 

The  specification  of  CPU  effects  directly  the  imaging  process  speed,  therefore  it  is  highly 

 

recommended to utilize a high-end CPU if possible. 

Memory 

 

In the viewer software, there is a data buffer which can store 4 to 8 frames. 

 

Therefore, it is necessary to keep spare space at least for 8 frames in the memory. 

 

(For  example,  when  using  1.3MP  color  camera,  1280  x  1024  x  3  x  8  [byte]  =  30[MB]  is 
necessary.) 

 

It is highly recommended to keep enough memory space especially when using high resolution 
camera.   

OS 

 

This camera is applicable only to the architecture of Windows NT (32bit/64bit). 

 

Standard functions are confirmed with OS after Windows 7. 

 

In addition, it is recommended to use Windows 10. 

 

 

Caution 

 

Please refer the restrictions below when you use ARTCAM series. 

(1) Recommended System Requirements 
If the system specifications do not meet the requirements recommended above, it may be difficult to 
run at the maximum frame rate.   
(2) Use of other USB3.0 Hardware 
The  data  on  our  camera/converter  is  transferred  in  bulk  mode.  For  this  reason,  when  using  our 
camera/converter, please avoid using other bulk transferred USB3.0 hardware such as Memory stick, 
External HDD, External DVD, CDROM etc.   
As  a  solution,  we  recommend  installing  a  PCI  USB  host  card  to  the  PC  and  connect  external  USB 
hardware to this port only. 
(3) USB3.0 Cable Extension 
We  cannot  guarantee  the  functionality  of  the  USB3.0  camera  if  the  user  adopts  USB3.0  extension 
cables  or  repeaters  which  are  not  confirmed  by  us.  With  the  extension  cables  or  repeaters,  the 
bandwidth of transfer may differ, and thus caused malfunctions such as a low frame rate or recognition 
failure on the camera. 
What  may  cause  the  problem  is  that  the  regulation  of  the  power  lines  becomes  not  enough,  and  so 
causes impudence mismatch on data signals. 
*For the recommended extension cable, please contact our sales department.   

(TEL: +81-3389-5488) 

 

Содержание ARTCAM-487UV

Страница 1: ...1 Jul 28 2022 Ver0 91 USB3 0 UV CMOS Camera ARTCAM 487UV INSTRUCTION BOOKLET 8 1 M Pixels ARTCAM 487UV ARTRAY CO LTD...

Страница 2: ...8 6 1 Camera Specifications 8 6 1 1 Camera specification list 8 6 1 2 Dimensional Outline 9 6 1 3 Schematic Diagram of the Sensor 10 6 2 Camera s Functions 11 6 2 1 Shutter Speed 11 7 Spectral Sensit...

Страница 3: ...ed 8 Please contact us if you find any unclear points or mistakes in this manual 9 Quoting copying or altering some or all parts of the manual without our permission is prohibited 10 We are not respon...

Страница 4: ...temperature places such as inside of vehicles or under direct sunlight High temperature may cause damages to the camera or even cause fires Do not cover the product with cloth or other materials The p...

Страница 5: ...nd regulations before actually exporting this product Guarantee To save the environment we do not issue warranty in printed format Instead all records of the warranty periods delivery dates and the cu...

Страница 6: ...adopted CMOS sensor has high sensitivity to the wavelength band between 200nm to 1000nm Therefore it is able to detect beyond the visible light region and visualizing things that difficult to be seen...

Страница 7: ...7 5 Connections 5 1 Connecting Method an example...

Страница 8: ...Global Shutter A D Resolution 12bits Interface USB3 0 Bulk Number of output bits 12bits Frame Rate 38fps Shutter Speed 0 1ms 26ms Synchronization System Internal Synchronization Lens Mount C Mount Pow...

Страница 9: ...9 6 1 2 Dimensional Outline Drawing of the base without a tripod mount...

Страница 10: ...10 6 1 3 Schematic Diagram of the Sensor...

Страница 11: ...posure time electronic shutter speed of the camera can be set The software supports from 0 1 ms to 26 ms The setting resolution on the software is in units of 100 s 0 1 ms and exposure time will be se...

Страница 12: ...UV Bandpass Filter U340 Optional ARTCAM 487UV is possible to choose to install an additional filter U340 which can absorb visible wavelengths and only allow ultraviolet wavelengths to pass Please ref...

Страница 13: ...Please refer the restrictions below when you use ARTCAM series 1 Recommended System Requirements If the system specifications do not meet the requirements recommended above it may be difficult to run...

Страница 14: ...14 ARTRAY CO LTD Obtained ISO 9001 2015 2018 9 17 1 17 5 Kouenjikita Suginami ku Tokyo 166 0002 Japan Tel 81 3 3389 5488 Fax 81 3 3389 5486 Email sales artray us URL www artray us...

Отзывы: