- 16 -
11.3.
Trigger Timing Chart
t1
Trigger input pulse width
10
μ
s or more
t2
From the start of the trigger
Internal trigger signal rise
About 2
μ
s or less
t3
Internal trigger signal pulse width
About 10
μ
s (fixed value)
t4
Sensor pixel reset period
Shutter setting value * 1 line time
(1 line time = 1790 * 1/24 [
μ
sec])
t5
Sensor exposure period
(1074 - Shutter setting value) * 1 line time
t6
From exposure completion to data
transfer
About 8 line hours
t7
Data transfer (sensor-FPGA)
1024 line time
≒
76 ms
t8
Data transfer (FPGA-USB
→
PC)
It depends on the USB transfer speed.
(Approximately 40 msec at standard speed)
t9
Software processing time
About 2 msec
(depending on CPU speed and processing content)
t10 Valid trigger acceptance interval
About 160 msec