Standard Frame Timing
T = Reset Time
TRIGGER
VD
HD
PCLK
row
16
row
17
row
18
row
19
row
n
-1
row
n
row
ǫ
T2
Remark1 : T is the time required for reset.
Start reset from trailing edge of trigger terminal.
Remark2 : The actual time for capturing is at least twice as long as the time indicated in Remark1(@8bits).
T2=Exposure/transfer time.Example of time calculated at 1280x1024
263
526
1053
1579
2105
4342
T
17.268ms
33.970ms
67.431ms 100.829ms 134.228ms
276.267ms
T2
82.287ms
98.989ms
132.450ms 165.840ms 199.247ms
341.286ms
Time(shutter_width value)
-5-
4 - 3
˴
External trigger *optional extras
1.Timing chart
2.External trigger hardware
Remark3 : From serial No. 00963 onward, photo-isolation version has been applied.
The following is the internal equivalent circuit.
VCC
2.4K
ǡ
External BNC
Connector
Input: 12-24 VDC,
either polarity
PC841
˴
Photocoupler
10K
ǡ
GND
External trigger