Страница 1: ...Artistic Licence Rail Split RJ45 User Guide Rail Split RJ45 Version 1 0 User Guide ...

Страница 2: ...s inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to penetrate...

Страница 3: ...puts Connections Mounting Diagram A passive loop through connection allows onward connection to other DMX512 devices If this feature is not required then the signal must be terminated To terminate slide off the outer guard so that the jumper connection ref 5 is visible Remove the black plastic shorting plug from the upper pin and place it over the lower pin Alternatively a plug in RJ45 terminator ...

Страница 4: ... y y DMX Fix mode to handle compatibility issues y y Mains powered y y RJ45 data connectors Connections Input The DMX512 input is via the RJ45 connector Loop Through A passive loop through connection allows onward connection to other DMX512 devices If this feature is not required then the signal must be terminated The product contains an internal termination link This is enabled by fitting the sho...

Страница 5: ... circuit No connection to Internal Logic Ground DMX512 Outputs Type Ground referenced Pins 7 8 Connected to Internal Logic Ground Internal Logic Ground Connects to Ground Power Input The following table summarises the internal earth interconnection and isolation Please note that we use the term Earth Ground to avoid international confusion In Europe Earth Ground is called Earth in the USA Earth Gr...

Страница 6: ...t the wide range of legal DMX timings and data Fixer mode attempts to clean out any unusual or non standard timing and data before sending to the output This includes stripping out all non zero start codes including RDM forcing a 512 channel footprint and calming any timing jitter Indicators have the following meaning Top Data As above Bottom Power Green Power Red I am fixing something Detailed Fi...

Страница 7: ...l y y Input power max 5 W y y Duty cycle 100 25 C y y DC fuse internal resettable fuse for control electronics DMX512 Outputs y y Mode ground referenced y y Isolation n a y y ESD protection 15 kV y y Electrocution protection All outputs protected against continuous connection to 425 VAC self healing DMX512 Input Loop y y Mode Optically isolated y y Isolation 1 kV y y ESD protection 15 kV y y Elect...

Страница 8: ...s manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE FCC and RoHS regulations Product specific information is available on request Waste Electrical Electronic Equipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continuing prod...