background image

 

Page 5 

Rail-Split RDM User Guide

Application Diagram

The diagram below shows how Rail-Split RDM could be utilised in a typical application.  

The following table summarises the internal earth interconnection and isolation. 
Please note that we use the term Earth-Ground to avoid international confusion. In Europe 

Earth-Ground is called Earth; in the USA, Earth-Ground is called Ground.

Internal Earth and Isolation

DMX Controller

Device 1

Terminated

DMX/RDM

DMX/RDM

DMX/RDM

DMX

PSU

Rail-Split RDM

in Split Mode

Rail-Split RDM

in Fix Mode

Terminated

Devices with DMX Compatibility Issues

Terminated

Device 2

Device 3

Device 4

Device 1

3

Device 32

Device 1

Device 2

Device 3

Device 4

Device 1

3

Device 32

Device 1

Device 2

Device 3

Device 4

Device 1

3

Device 32

Circuit

Description

DMX512 Input 

(including Loop Through)

Type:

Isolated

Pin 1:

Connects to internal isolated 

circuit. No connection to 

Internal Logic Ground

DMX512 Outputs

Type:

PSU referenced

Pin 1:

Connected to Internal Logic 

Ground

Internal Logic Ground

Connected to power supply 0V. If the selected PSU has a connection 

between Earth-Ground and 0V the DMX outputs become Ground 

Referenced. Otherwise the DMX outputs are Floating. When the 

recommended PSU is used, DMX outputs are Floating. 

Содержание Rail-Split RDM

Страница 1: ...Artistic Licence Rail Split RDM User Guide Rail Split RDM Version 5 0 User Guide Serial nos 4900 and upwards ...

Страница 2: ...s inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to penetrate...

Страница 3: ...RDM DMX only Power Collision Fix www ArtisticLicence com 4 1 3 2 7 7 5 7 6 Mounting Diagram 10 mm 88 mm 90 mm 62 mm 4 mm Rail Split RDM DMX512 RDM Splitter with protocol correction and filtering Artistic Licence DATA COM DATA Output 2 DATA COM DATA Output 3 DATA COM DATA Output 4 DATA COM DATA Output 1 GND 9 48V Power DATA COM DATA Output 5 DATA COM DATA Output 6 DATA COM DATA DMX512 DATA COM DATA...

Страница 4: ...d y y Surface mount or DIN rail mounted y y DMX Fix mode to handle compatibility issues Connections Input The DMX512 input is attached via three screw terminals Please refer to the connections diagram Loop Through A passive loop through connection allows onward connection to other DMX512 devices If this feature is not required then the signal must be terminated The product contains an internal ter...

Страница 5: ...M in Fix Mode Terminated Devices with DMX Compatibility Issues Terminated Device 2 Device 3 Device 4 Device 1 3 Device 32 Device 1 Device 2 Device 3 Device 4 Device 1 3 Device 32 Device 1 Device 2 Device 3 Device 4 Device 1 3 Device 32 Circuit Description DMX512 Input including Loop Through Type Isolated Pin 1 Connects to internal isolated circuit No connection to Internal Logic Ground DMX512 Outp...

Страница 6: ... the wide range of legal DMX timings and data Fixer mode attempts to clean out any unusual or non standard timing and data before sending to the output This includes stripping out all non zero start codes including RDM forcing a 512 channel footprint and calming any timing jitter Indicators have the following meaning Top Data As above Bottom Power Green Power Red I am fixing something Detailed Fix...

Страница 7: ...DC fuse internal resettable fuse for control electronics DMX512 Outputs y y Mode PSU referenced y y Isolation n a y y ESD protection 15 kV y y Electrocution protection All outputs protected against continuous connection to 425 VAC self healing DMX512 Input Loop y y Mode Optically isolated y y Isolation 1 kV y y ESD protection 15 kV y y Electrocution protection Input Loop protected against continuo...

Страница 8: ... manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE FCC and RoHS regulations Product specific information is available on request Waste Electrical Electronic Equipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continuing produ...

Отзывы: