Page 7
lightJuice CV4 User Guide
Port Settings
The virtual DMX port settings can be
configured via the web-browser using the
following columns:
y
Port: The DMX port number
y
DMX: Green shows changing data
y
Net, Sub-Uni: Set the port address for
this output
y
Protocol: Select either Art-Net or sACN
control over this output
y
Merge: Select HTP or LTP merge when
2 controllers send data to this port
Virtual RDM Device
lightJuice CV4 is treated as a virtual RDM
device, with 4 sub-devices corresponding
to each output channel of the RGBW circuit.
The start address of the sub-devices can be
chaged in the pull-down menu.
Before running DMX-Workshop, configure the
IPv4 settings of the network card being used
to connect to lightJuice CV4 as shown below.
The IP address can be anything in the 2.*.*.*
range so long as it is different from the IP
address of the lightJuice CV4.
DMX-Workshop™ is a software application
that runs on Windows XP / 7 / 8 / 10. It is a
fully featured network management, analysis,
configuration and diagnostics tool for Art-Net
networks. It is available as a free-of-charge
download from Artistic Licence:
http://tinyurl.
com/dmxartpage
DMX workshop screenshot
When lightJuice CV4 is connected to a
computer running DMX-Workshop, it should
be detected and displayed as an Art-Net
node (click the ‘Node List’ tab to verify this).
The node can be expanded to show the
configuration and DMX output information,
as shown in the screen-shot below.
The lightJuice CV4 unit is shown as an Art-
Net node (1) containing a virtual RDM device
(2). The RGBW circuit of lightJuice CV4 is
assigned its own 4 sub-devices (3).
Right-clicking on any entry brings up a menu
that offers various functionality:
y
The ‘Configure Node’ option enables
configuration of the Universe, Sub-Net
and Net values. It also allows the user to
give the device a short and long name.
y
‘Copy to clipboard’ enables all the node
information to be pasted into a support
request email.
y
‘Merge Controls’ (selectable only on
individual DMX outputs) enables the
choice of LTP or HTP merge modes.
y
‘Indicators’ enables selection of normal,
identify or mute for the LED indicators.
Normal is the default behaviour, identify
causes the power LED to flash, and
mute turns off all the LEDs.
y
‘RDM Devices’ offers options for device
discovery on RDM networks.
y
‘Advanced’ leads to ‘Configure IP
Address’, described in more detail below.
DMX-Workshop