background image

 

Page 2 

DMX-Buffer, DMX-Clarify & DMX-Protect User Guide

Please read these instructions before using the product.

This product has been designed & manufactured for professional use only. 

It should only be installed by a suitably qualified technician and in accordance with 

electrical regulations in the country of use.

Unless directed in the instructions there are no user serviceable parts inside the 

outer case of this product.

Always disconnect from the power supply when not in use.

Any specific IP rating, where appropriate, is given in the instructions. Unless 

otherwise stated this product is designed for indoor use only. If used outdoors it 

MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be 

exposed to rain or moisture. Do not allow liquid to penetrate the product.

Please recycle all packaging.

Copyright © Artistic Licence Engineering Ltd. All rights reserved.

Download the user guide by scanning the following QR code:

Содержание DMX-Buffer

Страница 1: ...Artistic Licence DMX Buffer DMX Clarify DMX Protect User Guide DMX Buffer DMX Clarify DMX Protect Version 1 1 User Guide ...

Страница 2: ...eable parts inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to...

Страница 3: ...y DMX Protect User Guide Reference Type Description 1 Connection Data out 2 Connection Data in 3 Connection Power Input 4 LED Power indication 5 LED Data indication 6 Connection GND Connections 6 DMX Buffer DMX Clarify DMX Protect ...

Страница 4: ...nd referenced Pin 1 Connected to Internal Logic Ground DMX512 Output Type Ground referenced Pin 1 Connected to Internal Logic Ground Internal Logic Ground Connects to Ground Power Input XLR Pin convention Function Colour RJ45 Pin Cable Colour 1 Ground Black 7 8 White Brown Brown 2 Data Blue 2 Orange 3 Data Red 1 White Or ange 4 Aux Data 6 Green 5 Aux Data 3 White Green ...

Страница 5: ...buffering the DMX signal The difference between the products lies in the way they handle RDM data DMX Protect is a passive in line protector designed to protect a DMX line from damage due to electrocution It has two levels of protection The first is a self healing circuit that protects against accidental connection to mains and will recover when the fault is removed The second is a protection of l...

Страница 6: ...elow DMX Clarify is used as an in line buffer to provide a filtered DMX signal to a group of fixtures that cannot handle RDM Terminated DMX Controller Fixture 32 Fixture 32 DMX DMX DMX Clarify Devices with DMX compatibility issues Fixture 1 Fixture 1 Fixture 2 Fixture 2 In the diagram below DMX Protect ensures that the DMX controller will not be damaged in the event of accidental mains connection ...

Страница 7: ...r only RJ45 Ethercon 1 no Control y y Input Protocols DMX512 DMX512 1990 DMX512 A RDM V1 0 E1 20 2006 ESTA Standard y y Output Protocols Same as input except that DMX Clarify does not output RDM LED Indication y y Power Data Package Contents y y DMX Buffer XLR or RJ45 or DMX Clarify y y User guide Accessories not included y y PSU 9 1 5 DCJ DMX Input y y Input mode Ground referenced y y Input isola...

Страница 8: ... All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE and RoHS regulations Product specific information is available on request Waste Electrical Electronic Equipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continu...

Отзывы: