background image

PB-SIO4A

Installation

ID 19958, Rev. 0300

Page 2 - 3

® 

PEP Modular Computers GmbH

2. Installation

2.1 Board Installation

To install a PB-SIO4A piggyback proceed as follows:

ensure that the safety requirements indicated above are observed

as required, ensure that the piggyback and carrier board are properly configured 
(see appropriate documentation for configuration) 

if required, remove the carrier board and optional adapters from the system

ensure the proper orientation of the PB-SIO4A to the carrier board before installing  
(see appropriate documentation for orientation)

press the piggyback onto the carrier board until fully seated 

Caution!

Switch off all power to the system and ensure that there are 

NO

external cables connected to the carrier board or to any optional
adapters connected to the carrier board before installing the PB-
SIO4A. Failure to do so could endanger your life/health and may
damage your board or system.

ESD Equipment!

Your PB-SIO4A board contains electrostatically sensitive devices.
Please observe the necessary precautions to avoid damage to
your board:

Discharge your clothing before touching the assembly. Tools
must be discharged before use.

Do not touch components, connector-pins or traces.

If working at an anti-static workbench with professional dis-
charging equipment, please do not omit to use it.

$

$

Note!

The PB-SIO4A can be installed in any free carrier board position,
and can be combined with any other type of piggyback module on a
carrier board. The only restraint here being the external interfacing
requirements, in particular, what type of cable connection is
required. It is the responsibilty of the system integrator to ensure
proper external interfacing to the PB-SIO4A. 

$

$

Note!

The PB-SIO4A can be securely mounted to the carrier board via
screws and stand offs as appropriate

Содержание PB-SIO4A

Страница 1: ...buy your excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of th...

Страница 2: ...PB SIO4A Quad Serial Port Piggyback RS422 RS485 Manual ID 19958 Rev Index 0300 Sep 99 The product described in this manual is in compliance with all applied CE stan dards ...

Страница 3: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 4: ...xplanation of Symbols 0 5 For Your Safety 0 6 High Voltage Safety Instructions 0 6 Special Handling and Unpacking Instructions 0 6 General Instructions on Usage 0 7 Two Years Warranty 0 8 Table of Contents 0 9 ID 19958 Rev 0300 Page 0 3 PEP Modular Computers GmbH ...

Страница 5: ...rs reserve the right to change modify or improve this document or the product described herein as seen fit by PEP Modular Computers without further notice Trademarks PEP Modular Computers the PEP logo and CXM are trade marks owned by PEP Modular Computers GmbH Kaufbeuren Germany In addition this document may include names company logos and trademarks which are registered trademarks and therefore p...

Страница 6: ...u that electronic boards and their components are sensitive to static electricity There fore care must be taken during all handling operations and inspections of this product in order to ensure product integ rity at all times Please read also the section Special Handling and Unpack ing Instructions of this manual Attention This symbol and title emphasize aspects which if not read through carefully...

Страница 7: ...ly done by touching a metal part of your system housing It is particularly important to observe standard anti static precautions when changing piggybacks ROM devices jumper settings etc If the product contains batteries for RTC or memory back up ensure that the board is not placed on conductive surfaces includ ing anti static plastics or sponges They can cause short circuits and damage the batter ...

Страница 8: ...the operational temperature range of the specific board version which must not be exceeded If batter ies are present their temperature restrictions must be taken into account In performing all necessary installation and application operations please follow only the instructions supplied by the present manual Keep all the original packaging material for future storage or warranty shipments If it is...

Страница 9: ...vent of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to PEP Modular Computers and the remaining part of the original guarantee or any new guarantee to cover the repaired or replaced items will be transferred to cover the new or repaired items Any extensions to the original guarantee are considered gestures of goodwill and will be defined in the...

Страница 10: ...gram 1 5 1 4 PB SIO4A External Interfacing 1 5 1 5 Carrier Board External Connectors 1 6 1 6 Technical Specifications 1 7 1 7 Applied Standards 1 8 1 8 Related Publications 1 8 Chapter 2 2 Installation 2 3 2 1 Board Installation 2 3 2 2 Software Installation 2 4 Chapter 3 3 Configuration 3 3 3 1 PB SIO4A Address Map and ID Byte 3 3 3 2 VMEbus Interrupts 3 3 3 3 Jumper Settings 3 4 3 4 Pinouts 3 5 ...

Страница 11: ...Preface PB SIO4A ID 19958 Rev 0300 Page 0 10 PEP Modular Computers GmbH Chapter 4 4 Adapter AD SIO4 4 3 4 1 Product Overview 4 3 4 2 Adapter Overview 4 3 ...

Страница 12: ...rd Overview 1 3 1 3 Functional Block Diagram 1 5 1 4 PB SIO4A External Interfaceing 1 5 1 5 Carrier Board External Connectors 1 6 1 6 Technical Specifications 1 7 1 7 Applied Standards 1 8 1 7 1 CE Compliance 1 8 1 7 2 Mechanical Compliance 1 8 1 7 3 Environmental Tests 1 8 1 8 Related Publications 1 8 1 8 1 General 1 8 1 8 2 PEP Modular Computers 1 8 Chapter 1 ...

Страница 13: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 14: ...ated by the DUART s Board ID byte for remote software configuration identity checking Compact size four serial ports within standard industrial I O piggyback dimen sions Easy to maintain Quick and simple replacement if required Hardware Full electrical and mechanical compatibility with the extensive range of carrier boards All required VMEbus lines are available on the piggyback Optional optoisola...

Страница 15: ...laced with wire bridges on the non optoisolated versions For operational configuration of this piggyback there are solder jumpers located both on the front and rear side of the board Figure 1 1 PB SIO4A Board Front View Optoisolated Version Figure 1 2 PB SIO4A Board Rear View Optoisolated Version 1 2 25 26 ST102 1 2 29 30 ST101 DUART I F Logic Opto isolation Opto isolation Opto isolation Transmitt...

Страница 16: ...double row flat ribbon cable connector locking 50 pin female Dsub connector On Board 50 pin male double row flat ribbon cable connector head In conjunction with the carrier board s connectors there is also the possbility of provid ing connection to external devices using the AD SIO4 adapter This adapter utilizes either of the carrier board s flat ribbon connectors to provide 4 15 pin female Dsub c...

Страница 17: ...ev 0300 Page 1 6 PEP Modular Computers GmbH 1 5 Carrier Board External Connectors Figure 1 4 Carrier Board External Connector Types 1 2 49 50 50 Pin Male Front Panel 50 Pin Female 50 Pin Male 1 1 2 49 50 50 34 17 Front Panel On Board ...

Страница 18: ...and force parity 1 1 and 2 stop bits Programmable Channel Modes normal full duplex automatic echo local loopback remote loopback Counter Timer two 16 bit one for each DUART Identification Byte E7 hex DTACK Generation on board Power Supply 5V DC 5 Power Consumption 0 4A typical Temperature Range Operating 0 C 70 C Standard 40 C 85 C Extended Humidity 0 95 non condensing Dimensions Width 48 mm 17 8 ...

Страница 19: ...l Safety EN60950 1 7 2 Mechanical Compliance Mechanical Dimensions IEEE 1101 10 1 7 3 Environmental Tests Vibration Broad Band IEC68 2 6 Random Vibration IEC68 2 64 3U boards Permanent Shock IEC68 2 29 Single Shock IEC68 2 27 1 8 Related Publications 1 8 1 General VMEbus Specification Revision C 1 The MC68681 data sheet from Motorola 1 8 2 PEP Modular Computers Please contact PEP Modular Computers...

Страница 20: ...PB SIO4A ID 19958 Rev 0300 Installation Page 2 1 PEP Modular Computers GmbH Installation 2 1 Board Installation 2 3 2 2 Software Installation 2 4 2 2 1 Driver Installation 2 4 Chapter 2 ...

Страница 21: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 22: ... board before installing the PB SIO4A Failure to do so could endanger your life health and may damage your board or system ESD Equipment Your PB SIO4A board contains electrostatically sensitive devices Please observe the necessary precautions to avoid damage to your board Discharge your clothing before touching the assembly Tools must be discharged before use Do not touch components connector pins...

Страница 23: ...cables to the carrier board and optional adapters as required ensure that the carrier board optional adapters and interfacing cables are properly secured 2 2 Software Installation 2 2 1 Driver Installation Drivers are available for various operating systems but are not delivered with the PB SIO4A If required please order the appropriate driver separately For installation of any required driver ple...

Страница 24: ...H Configuration 3 1 PB SIO4A Address Map and ID Byte 3 3 3 2 VMEbus Interrupts 3 3 3 3 Jumper Settings 3 4 3 4 Pinouts 3 5 3 4 1 PB SIO4A Carrier Board Connector ST101 3 5 3 4 2 PB SIO4A Carrier Board Connector ST102 3 6 3 4 3 PB SIO4A to Carrier Board to AD SIO4 3 7 Chapter 3 ...

Страница 25: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 26: ...ART2 Base Address 41 ID Byte Piggyback location B the lower position on the carrier board Base Address 81 DUART1 Base Address A1 DUART2 Base Address C1 ID Byte The PB SIO4A has an ID Byte of E7 RS422 RS485 3 2 VMEbus Interrupts Each DUART device is able to issue an interrupt request IRQ to the carrier board In the event of simultaneous interrupt requests those from DUART 1 have priority over those...

Страница 27: ...per Settings Jumper Channel Setting Default Function B53 A 2 3 1 2 1 3 1 2 3 X receiver and driver line connected pull up resistor for driver line pull up resistor for receiver line pull up resistor for driver and receiver line B55 B B57 C B59 D B54 A 2 3 1 2 1 3 X receiver and driver line connected pull down resistor for driver line pull down resistor for receiver line B56 B B58 C B60 D B61 D clo...

Страница 28: ... header connector which provides interfacing between the PB SIO4A and CPU side of the carrier board Table 3 2 Pinout of Connector ST101 Signal Pin Pin Signal 5V Vcc 30 29 GND IA1 28 27 ID0 IA2 26 25 ID1 IA3 24 23 ID2 IA4 22 21 ID3 IA5 20 19 ID4 IA6 18 17 ID5 IAS 16 15 ID6 IDS0 14 13 ID7 N C 12 11 INT CS 10 9 INTA DTACK 8 7 RESET CLK 6 5 R W 12V 4 3 12V 5V Vcc 2 1 GND ...

Страница 29: ...ector which provides interfacing between the PB SIO4A and the application side of the carrier board Table 3 3 Pinout of Connector ST102 Signal Pin Pin Signal RxD D 26 25 RxD D GndE 24 23 TxD A TxD A 22 21 VccE RxD A 20 19 RxD A GndE 18 17 TxD B TxD B 16 15 VccE RxD B 14 13 RxD B GndE 12 11 TxD C TxD C 10 9 VccE RxD C 8 7 RxD C GndE 6 5 TxD D TxD D 4 3 VccE RxD D 2 1 RxD D ...

Страница 30: ...ON CH U P P E R 2 RxD D 1 2 50 24 11 BU4 D RxD D 25 26 49 23 10 VccE 3 48 22 15 TxD D 4 47 21 8 TxD D 5 46 20 9 GndE 6 45 19 1 7 RxD C 7 44 18 11 BU3 C RxD C 8 43 17 10 VccE 9 42 16 15 TxD C 10 41 15 8 TxD C 11 40 14 9 GndE 12 39 13 1 7 1 RxD B 13 38 12 11 BU2 B RxD B 14 37 11 10 VccE 15 36 10 15 TxD B 16 35 9 8 TxD B 17 34 8 9 GndE 18 33 7 1 7 RxD A 19 32 6 11 BU1 A RxD A 20 31 5 10 VccE 21 30 4 ...

Страница 31: ...dE 6 19 19 1 7 RxD C 7 18 18 11 BU3 C RxD C 8 17 17 10 VccE 9 16 16 15 TxD C 10 15 15 8 TxD C 11 14 14 9 GndE 12 13 13 1 7 1 RxD B 13 12 12 11 BU2 B RxD B 14 11 11 10 VccE 15 10 10 15 TxD B 16 9 9 8 TxD B 17 8 8 9 GndE 18 7 7 1 7 RxD A 19 6 6 11 BU1 A RxD A 20 5 5 10 VccE 21 4 4 15 TxD A 22 3 3 8 TxD A 23 2 2 9 GndE 24 1 1 1 7 Table 3 4 PB SIO4A to Carrier Board to AD SIO4 Pinout Table Both Positi...

Страница 32: ...PB SIO4A ID 19958 Rev 0300 Adapter AD SIO4 Page 4 1 PEP Modular Computers GmbH Adapter AD SIO4 4 1 Product Overview 4 3 4 2 Adapter Overview 4 3 Chapter 4 ...

Страница 33: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 34: ... connectors for internal connection to the PB SIO4A carrier board Connection from the carrier board to the adapter is done via a 50 way flat band cable with a 50 pin dual row female connector for the carrier board and two 24 pin dual row female con nectors for connection to the adapter This cable allows for the connection of two PB SIO4A s to two AD SIO4 s where pins 25 and 26 are not used See Tab...

Страница 35: ...another serial interface piggyback from PEP Note Always ensure that the correct connector of the adapter cable is connected to BU6 See Table 3 4 for cable pinout Note For use with the PB SIO4A ensure that there is no cable connected to BU5 Failure to comply with this will result in misfunctioning and possible damage to equipment USE FOR PB SIO4A RESERVED DO NOT USE see note below BU6 BU5 1 2 24 23...

Страница 36: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Отзывы: