cFP-2200/2210/2220
18
ni.com
Figure 21.
Installing a Connector Block on the Backplane
4.
Using a number 2 Phillips screwdriver with a shank of at least 64 mm
(2.5 in.) length, tighten the captive screws to 1.1 N · m (10 lb · in.) of
torque.
5.
Repeat this procedure to install additional connector blocks on the
backplane.
Connecting the cFP-22
xx
to a Network
Connect the cFP-22
xx
to an Ethernet network using RJ-45 Ethernet port 1
on the controller front panel. Use a standard Category 5 (CAT-5) or better
Ethernet cable to connect the controller
to an Ethernet hub, or use an
Ethernet crossover cable to connect the controller directly to a computer.
Caution
To prevent data loss and to maintain the integrity of your Ethernet installation,
do
not
use a cable longer than 100 m. If you are using 100 Mbps Ethernet, National
Instruments recommends using a CAT-5 or better shielded twisted-pair Ethernet cable.
cFP–2220
PO
WER
READ
Y
RE
S
ET
PO
WER
S
TAT
U
S
cFP–DI–
3
04
CA
UTION –
S
EE U
S
ER MANU
A
L
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com