INSECT WARNING:
•
Spiders and insects can nest in the burners of this and other appliances, adversely effecting the gas
flow to the burner. This is a very dangerous condition which can cause a fire to occur behind the
valve panel, thereby damaging the appliance, making it unsafe to operate. Inspect the unit at least
twice a year.
•
Be sure that the appliance is turned off and cool before using any type of aerosol cleaner on or
around the appliance. The chemical that produces the spraying action could, in the presence of heat,
ignite or cause metal parts to corrode.
•
Do not operate the appliance under unprotected combustible construction. Use only in well ventilated
areas. Do not use in buildings, garages, sheds, breezeways or any enclosed areas.
•
Keep the area surrounding the appliance free from combustible materials, trash, or combustible fluids
and vapors such as gasoline or charcoal lighter fluid. Do not obstruct the flow of combustion gases
and ventilation airways.
•
If the unit is stored indoors, ensure that it is cool. If propane is used, the cylinder must be unhooked
and the propane cylinder stored outside in a well-ventilated area, out of reach of children.
•
Never use the appliance in windy conditions. If located in a consistently windy area, oceanfront,
mountaintop, etc... a windbreak may be required. Always adhere to the specified clearances.
WARNING
FOR OUTDOOR USE ONLY
NOT TO BE INSTALLED IN OR
O N R E C R E A T I O N A L
VEHICLES AND / OR BOATS.
WARNING
NEVER USE A DENTED OR
RUSTED LIQUID PROPANE
TANK. SHUT OFF TANK
WHEN NOT IN USE.
GAS CONNECTION - LIQUID PROPANE (LP):
NOTE: THIS APPLIES TO LP MODELS ONLY. LP MODELS HAVE THE LETTERS “LP” IN THE
MODEL NUMBER.
NEVER CONNECT THE APPLIANCE TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury.
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP
Operating: 10.0” W.C.
Non-operating:
11.2” W.C.