background image

 

                                         

 

 

-

 

Settings: 6 dip switch to configure the DynamicTalk. 

 
 
Dip switch 

Function 

1,2,3 ON: DynamicTalk configured as PA mode. The Talk push 

button controls the microphone mute function 
OFF: DynamicTalk configured as conference mode. The 
talk push button has no function but the contact close is 
present on GPO connector and the ring LED is externally 
controlled 

4, 5 

Only factory. Leave those dip switches off 

Termination of the RS422 bus. Configure to ON only in 
the last device of the RS422 bus 

 

 

-

 

AHnet: RJ45 CAT5 connector for addressable RS422 control. There is a 
loop through connector to use as signal RS422 output. You can 
connect up to 30 units on the same RS422 bus 

-

 

AHnet ADDRESS: Using the AHnet protocol, this is the number of the 
device into the RS422 addressable bus 

 
Microphone length setting procedure. 
 
Dynamic Talk is designed to work with microphones of different lengths. 
Two signs to identify an incorrect setup of the microphone length are:  
 
•The microphone do not goes down completely.  
•The microphone goes down too low, and gets stucked inside. The 
microphone length can be adjusted using Monitor Configurator Tool, but 
there is a quick procedure not requiring the PC and the cabling 

 
 PROCESS  
1. Disconnect Power connector 
2. Set switch 5 to ON position 
3. Set the length of the microphone in the rotatory 
switch, in cm. For instance, if the microphone is 
40cm, set the rotatory switch as: tens=4, unit=0) 
4. Connect Power , there will be a 5 beep sound 
5. Disconnect Power 
6. Set switch 5 to OFF position 
7. Set the AHnet address in the rotatory

 

switch, 

the default setting is address 01 (tens=0, units=1).

  

8. Connect Power connector

 

Содержание AHDTLM UC

Страница 1: ...User manual __________________________________________________ AHDTLM UC Motorized microphone system for underneath installation...

Страница 2: ...screens are a part of the interior design as well as essential communication tools Please read this installation and operating instructions carefully and keep them in a safe place for a future consult...

Страница 3: ...3 Table of contents FEATURES 6 BOX CONTENTS 6 CONTROLS 7 CONNECTIONS 8 AHNET PROTOCOL 10...

Страница 4: ...sk of electronic shock This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit This symbol indicates that the equipment conforms to the norms...

Страница 5: ...outlet must be in an easily accessed place Environment Install the equipment on an elevated flat surface Install the equipment in a ventilated area Avoid exposing the equipment to Rain or water Excess...

Страница 6: ...Dynamic LED ring for ready to talk and talk indications Up Down movement for external push buttons Down control movement for cover plate button Push button to MUTE function in PA mode or used to GPO i...

Страница 7: ...that the mute is not active and you can talk to the audience Press once the button the ring LED change to green indicating that the MUTE is active and the microphone is not working Conference mode In...

Страница 8: ...nly in conference mode Contact close of the TALK push button on upper cover plate only in conference mode This function is not working when the device is configured in PA mode 100mA Max 2 Only in conf...

Страница 9: ...is the number of the device into the RS422 addressable bus Microphone length setting procedure Dynamic Talk is designed to work with microphones of different lengths Two signs to identify an incorrect...

Страница 10: ...answer Pins 3 6 the units receive orders Protocol to control the device by addressable RS422 bus You can connect up to 30 dvices on the same RS422 bus You can use a AH Interface Ethernet to control t...

Страница 11: ...XX 04 00 00 BUTTON UN LOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the DynamicTalk address Up to 30 units for each RS422 BUS CB1 Response in 8 bites of the dev...

Страница 12: ...12...

Страница 13: ...to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local author...

Страница 14: ...oth freight and insurance will be paid by Albiral Display Solutions S L Although Albiral Display Solutions S L pays for transport and insurance cost Albiral Display Solutions S L will not be responsib...

Страница 15: ...15...

Страница 16: ...Hip lit de Voltreg 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice Arthur...

Отзывы: