Страница 3: ... CONTENTS EC REGULATIONS AND SECURITY 6 SAFETY INSTRUCTIONS 6 SYSTEM DESCRIPTION 8 CONTROLS 9 AHLINK 10 MICROPHONE INSTALLATION 13 AHNET PROTOCOLS 15 INFORMATION ON DISPOSAL 17 WARRANTY TERMS AND CONDITIONS 18 ...

Страница 4: ... integration and for a maximum reliability Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions that would help us improve our products Henrik Holm General Manager hholm albiral com ...

Страница 5: ... based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and ergonomic products that...

Страница 6: ...ximum allowed by the cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord EC REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shoc...

Страница 7: ... the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30 mm in order to have good ventilation Never place above the device any sources of flames such as lighted candles etc If you are using the device in extreme weat...

Страница 8: ... of providing commands for automatic mute of the microphone depending on the model and maker of the microphone when moving and in storage position The microphone lift is powered using PoE making it easy and compact to install and control The housing is made out of steel and the upper cover plate is made in stainless steel Features Motorised lift for boundary microphone Touch control sensor on cove...

Страница 9: ...the input on the power supply and then connect the cable to the network Connect the power supply to the power source The device is powered and connected to your network Minimum power required 30W PoE For remote control see AHnet protocol Controller Board Settings Deep1 Wireless connection ON OFF Down position Wireless connection active Up position Wireless connection not active Leave the rest of t...

Страница 10: ...d of 5 beeps will indicate that the AHlink signal is active on the unit The unit automatically deactivate the AHlink signal if there is no device mobile or tablet connected for more than 2 minutes The user can also deactivate the AHlink signal using the APP on mobile or tablet When the AHlink signal is deactivated the sound of long beep will indicate that the AHlink is not longer available on the ...

Страница 11: ...nk name always begins with AH characters and the fourth last MAC AHlink address Select the device to control and set up the unit When selecting the device the first page will upload on the mobile phone This page is used to check the device and for basic diagnostic during the installation process ...

Страница 12: ...s brightness SAVE VALUES Memorizes the the backlight contrast and brightness values AHLINK OFF Turns off the AHlink signal COMMAND Information of the last AHnet command received from RS422 port SENSORS Indicates sensor status S1 indicates the screen is completely opened AHNET ADDRESS Configuration of the AHnet address of the unit password POSITION Indicates the position of the screen Value 0 indic...

Страница 13: ... GATEWAY 2 Second network gateway number GATEWAY 3 Third network gateway number GATEWAY 4 Fourth network gateway number MIC_IP 1 First network microphone IP number MIC_IP 2 Second network microphone IP number MIC_IP 3 Third network microphone IP number MIC_IP 4 Fourth network microphone IP number NETWORK INI Press this button to send the new network configuration to the device If you don t press t...

Страница 14: ...hone 2 Plug the network cable into the microphone and guide it through the center exit path When the cable is secured guide it through the tube anchor piece 3 Align the tube into the recessed area in the center of the microphone Put the 3 screws on removed in step 1 to secure the tube anchor piece ...

Страница 15: ...g it vertically matching the hole of detail A and turning it 90º clockwise 5 To remove the microphone pull the microphone slightly upwards and turn it 90º anticlockwise Now the microphone can be extracted vertically To remove the cable follow steps 1 2 and 3 reversed ...

Страница 16: ...ata RX 4 NC 5 NC 6 Data RX 7 NC 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the unit by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus You can use a AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500 m 1640 f...

Страница 17: ...rt 2002 send AHnet command and close port Using 5 bytes communication BYTE 0 START BYTE BYTE 1 ADDRESS BYTE BYTE 2 COMMAND BYTE BYTE 3 VALUE 1 BYTE 4 VALUE 2 Commands COMMAND DESCRIPTION RESPONSE FA XX 01 01 00 OPEN FB 01 01 01 00 FA XX 01 00 00 CLOSE FB 01 01 00 00 FA XX 04 01 00 BUTTON LOCK FB 01 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB 01 04 00 00 ...

Страница 18: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Страница 19: ...iral Display Solutions Although Albiral Display Solutions pays for transport and insurance cost Albiral Display Solutions will not be responsible for the damages caused by transport if the customer does not inform in writing immediately when receiving the goods II After 90 days of the purchase date the beneficiary of the warranty will pay both freight and insurance costs Albiral Display Solutions ...

Страница 20: ... the transport 8 The warranty is not valid if the beneficiary of the warranty does not include RMA form and copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you have any doubts concerning the terms of this warranty please contact business albiral com 34 938 502 376 Copyright Dec 2020 All rights reserv...

Страница 21: ......

Страница 22: ......

Страница 23: ... Sant Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG June 2020 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P31...

Отзывы: