14
INPUT CONNECTORS
DVI 1/ DVI A:
DVI-I input signal. Connect a DVI (digital) input signal and
select DVI 1 on the OSD monitor menu. Use a DVI to VGA adaptor to connect
an ARGB (analogue) input signal and select DVI-A on the OSD monitor menu.
DVI 2:
DVI-D input signal. Connect a DVI (digital) input signal and select DVI 2 on
the OSD monitor menu.
12V D.C.:
Power supply input connector.
Address:
AHNet address for the addressable AHNet command protocol.
Address 00 is reserved for service.
Termination:
Activate (ON) the termination. Only on the last unit of the
RS422 bus.
AHnet:
RJ45 CAT6 connector for addressable RS422 control. There is a loop
through connector to use as signal RS422 output. Up to 30 devices can be
connected on the same RS422 bus.