5. Trouble shooting
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link
properly.
2. If the DMX LED is on and no response to the channel, check the address
settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on
PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that
may cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is
broken.
2. The motor
’
s drive IC on the PCB might be out of condition.
5
DMX:19/27 chs
CONTROL / CONNECTIONS
DMX Channel Modes ( 17chs)
Stand-alone mode and Master/Slave modes
4 Button Touch Control Panel
LCD Menu Display
3pin, 5pin DMX In/Out
powerCON In
ELECTRICAL / THERMAL
AC 100-240V - 50/60Hz
300W Max Power Consumption
-13°F to 113°F (-25°C to 45°C)
APPROVALS / RATINGS
FCC | CE | RoHs Compliant | IP20
SIZE / WEIGHT
:
Length: 10.2" (260mm)
Width: 8.66", (220mm)
Vertical Height:16.8", (430mm)
Weight: 18.3lbs. (8.3 kg)
3. How To Control
The Unit
The DMX512 is widely used in intelligent lighting control,with a DMX 512
controller.connect several lights together,dmx in and dmx out,