ARTEX/ACR Electronics, Inc.
A3-06-2824 Handheld Programmer Operations Manual
Y1-03-0272 Rev. F
Company Confidential
Page 31
7.
You may then click on the other number system selection to see the converted
value (Octal or Hex).
NOTE
: The 3-digit country code is automatically determined from the country
data encoded in the 24-bit address.
8.
Go to Graffiti screen and tap on letter/numbers.
9.
Enter aircraft 24-bt address.
10.
Tap
“
Done
”
when finished.
11.
Tap “ENTER” button on
Program screen. The 32-digit hex code is shown at the
bottom of the screen, with the abbreviated 15-digit hex code below it.
12.
For ELT 345s or ELT 1000s only:
tap “Program”; quickly place ELT switch in
the test mode and release. (Quickly is <1 second).
13.
Tap the “Program” button to program the ELT
.
14.
Ensure that screen shows “Programming Successful”.
15.
Verify ELT using
Sarcalc”
, as described in Subsection 6.2.
4.7.11
Std Location / ELT Serial (Long)
1.
Select ELT Baud rate.
2.
For the ELT 345 and ELT 1000, refer to Note 1 on page 23 before continuing.
3.
For the ELT 3000 and ELT 4000, refer to Note 2 on page 23 before continuing.
4.
Select Protocol.
5.
Select Country Code.
6.
Go to Graffiti screen and tap on letter/numbers.
7.
Enter the serial number, which matches the serial number seen on the product
label, or a number that was designated for use by the competent national
authority.
8.
Enter the COSPAS-SARSAT TAC number.
9.
Tap
“
Done
”
when finished.
10.
Tap “ENTER” button on Program screen
. The 32-digit hex code is shown at the
bottom of the screen, with the abbreviated 15-digit hex code below it.
11.
For ELT 345s or ELT 1000s only:
tap “Program”; quickly place ELT switch in
the test mode and release. (Quickly is <1 second).
12.
Tap the “Program” button to program the ELT
.
13.
Ensure that screen shows “Programming Successful”.
14.
Verify ELT u
sing “Sarcalc
, as described in Subsection 6.2.