Operating faults
When starting up
• The compressor does not work >
check that the wall socket is supplied with power by plugging in
another electrical appliance.
• The compressor never stops >
put your hand on the condenser (grill located on the back of the
appliance). If the condenser is cold, contact your retailer.
If the condenser is hot, set your cabinet (ST1) to the maximum temperature setting value. If the compressor
still does not stop, contact your retailer.
• The wine cabinet does not switch on >
contact your dealer
ANY WORK CARRIED OUT BY TECHNICAL SERVICES NOT APPROVED BY ARTEVINO
SHALL RENDER THE WARRANTY NULL AND VOID.
THE USE OF A GLASS DOOR CAN AFFECT THE PERFORMANCE OF YOUR WINE CABINET
IN SOME EXTREME TEMPERATURE CONDITIONS.
Standards
Your product meets the following standards:
1- Safety
Directive 2006/95/CE
Standard
EN60335-1 : Version 5-2010+A1+A2+A11+A12+A13
EN60335-2-24 : Edition 7-2010+A1+A2+A11
2- EMC
Directive
2004/108/CE
Standard
EN55014-1/2
3- Environment
Directive 2010/30/EU
Regulation 1060/2010
R600a
Depending on the country, ArteVino
wine cabinets may contain flammable
refrigerant gas (R600a: ISO BUTANE).
Technical features and data relating to European
regulations on power consumption
* Measured with an external temperature of 25°C.
Energy consumption calculated based on the result obtained over 24 hrs in standard test conditions. Actual energy consumption
depends on the appliance’s location and operating conditions.
This appliance is intended solely for storing wine.
Category of all models:2
Climate class: our appliances are designed to be used at an ambient temperature of 10°C - 32°C - Class
SN – Nevertheless, refer to the table of technical features above to find out the optimal performance for your product.
These models cannot be flush-fitted.
** Depending on the country, these values can vary; to find out the specific properties of your appliance, consult your appliance’s
product identification label.
*** R600a gas. With a R134a gas (for US, CA, Korea, Taïwan) : 38 db(A).
Model
H x W x D
(mm)
Weight
(Kg)
Useful
volume
(litres)
Accuracy
(+/-)
Voltage** (V)
/ Frequency**
(Hz)
Electrical
power*
(Watts)
Consum-
ption
(kWh/
24hrs)*
Recommended
T° range
(T° mini -
T°maxi)
Energy
efficiency
class
Annual energy
consumption
AEc*
(Kwh/year)
Sound
emission
(db(A))***
Single temperature cabinets
OXG1T230NPD/PPD
1825 x 680 x 700
72
460
1,5°C
230/50
70
0,35
0°C - 35°C
A+
128
37
OXG1T230NVD
1825 x 680 x 690
86
460
1,5°C
230/50
70
0,59
0°C - 30°C
B
216
37
OXM1T182NPD/PPD
1480 x 680 x 700
63
355
1,5°C
230/50
65
0,33
0°C - 35°C
A+
121
37
OXM1T182NVD
1480 x 680 x 690
74
355
1,5°C
230/50
65
0,52
0°C - 30°C
B
190
37
OXP1T98NPD/PPD
960 x 680 x 700
45
225
1,5°C
230/50
60
0,31
0°C - 35°C
A+
114
37
OXP1T98NVD
960 x 680 x 690
52
225
1,5°C
230/50
60
0,47
0°C - 30°C
B
172
37
2-temperature cabinets
OXG2T206NPD
1825 x 680 x 700
72
445
1,5°C
230/50
70
0,46
12°C - 25°C
A
168
37
OXG2T206NVD
1825 x 680 x 690
86
445
1,5°C
230/50
70
0,74
12°C - 25°C
C
271
37
Multi-temperature cabinets
OXGMT225NPD
1825 x 680 x 700
72
460
1,5°C
230/50
70
0,35
12°C - 30°C
A+
128
37
OXGMT225NVD
1825 x 680 x 690
86
460
1,5°C
230/50
70
0,59
12°C - 30°C
B
216
37
OXMMT177NPD
1480 x 680 x 700
63
355
1,5°C
230/50
70
0,33
12°C - 30°C
A+
121
37
OXMMT177NVD
1480 x 680 x 690
74
355
1,5°C
230/50
70
0,52
12°C - 30°C
B
190
37
OXPMT98NPD
960 x 680 x 700
45
225
1,5°C
230/50
65
0,31
12°C - 30°C
A+
114
37
OXPMT98NVD
960 x 680 x 690
52
225
1,5°C
230/50
65
0,47
12°C - 30°C
B
172
37
3-temperature cabinets
OXG3T199NPD
1825 x 680 x 700
79
450
1,5°C
230/50
70
0,35
12°C - 30°C
A+
128
37
OXG3T199NVD
1825 x 680 x 690
93
450
1,5°C
230/50
70
0,59
12°C - 30°C
B
216
37
OXM3T151NPD
1480 x 680 x 700
70
345
1,5°C
230/50
65
0,33
12°C - 30°C
A+
121
37
OXM3T151NVD
1480 x 680 x 690
81
345
1,5°C
230/50
65
0,52
12°C - 30°C
B
190
37