Maps and Registers
ATCA-7480 Installation and Use (6806800T17A
)
166
When at least one bit of the
is set, the corresponding status bit
CLK_MONITOR_FINISHED of the
is also set.
When at least one bit of the
is set, the corresponding status bit
CLK_MONITOR_OUT_OF_RANGE of
is also set.
Table 5-92 Telecom Clock Monitor Status Register
Address: 0x61
Bit
Description
Default
Access
3:0
Result available for supervised Telecom Clock 0 to 3.
Corresponding bit is set when measurement has
finished.
Clearing bit triggers new measurement.
0
LPC: r/w1c
7:4
Reserved
0
r
Table 5-93 Telecom Clock Monitor Out of Range Register
Address: 0x62
Bit
Description
Default
Access
3:0
Frequency of supervised Telecom Clock 0 to 3 is out of range.
Gate Mode:
Corresponding bit is set when the number of positive Clock
edges within the selected time base is:
< Lower limit or
> Upper limit
Period Mode:
Corresponding bit is set when the Clock 0 Period within the
selected time base is:
< Lower limit or
> Upper limit
Clearing bit triggers new sequence of measurements.
0
LPC: r/w1c
7:4
Reserved
0
r
Содержание ATCA-7480
Страница 1: ...ATCA 7480 Installation and Use P N 6806800T17A February 2015...
Страница 24: ...ATCA 7480 Installation and Use 6806800T17A About this Manual 24 About this Manual...
Страница 30: ...ATCA 7480 Installation and Use 6806800T17A Safety Notes 30...
Страница 36: ...ATCA 7480 Installation and Use 6806800T17A Sicherheitshinweise 36...
Страница 42: ...Introduction ATCA 7480 Installation and Use 6806800T17A 42...
Страница 64: ...Hardware Preparation and Installation ATCA 7480 Installation and Use 6806800T17A 64...
Страница 82: ...Controls Indicators and Connectors ATCA 7480 Installation and Use 6806800T17A 82...
Страница 98: ...Functional Description ATCA 7480 Installation and Use 6806800T17A 98...
Страница 222: ...BIOS ATCA 7480 Installation and Use 6806800T17A 222...
Страница 326: ...Replacing the Battery ATCA 7480 Installation and Use 6806800T17A 326...
Страница 329: ......