
Base Operating System
SharpStreamer™ Pro PCIE-7210 Installation and Use ( 6806800U29D
)
104
6. Provide the path of the installable files location.
What is the installation files directory? []
/media/usbdrive/images
If booted from USB drive, then installable files are available in the
/images
directory.
The script performs formatting, partitioning and installation.
7. To set date/time, provide
NTPSERVER
details or set date/time manually.
When installation is done a message is displayed accordingly.
8. Reboot the card. Go to BIOS and then perform the following settings.
a. Select
UEFI
mode
b. Enable Network Stack
c. Go to
Device manager
>
iSCSI configuration
(iSCSI initiator name and under
attempt) and make sure to provide the exact options which are provided during the
installation. For example, initiator IQN, target IQN, target IP, target port, and initiator
interface.
9. Login. For more information, refer to the section
6.3
Linux Distribution
The distribution is based on CentOS 7.2. The Kernel version is provided in the
SharpStreamer™
Pro PCIE-7210 PCIE Update Release Notes
. Contact your local Artesyn sales executive for more
information.
The default runlevel is
3
. The root file system does not contain any graphical interface
packages. The following table shows the default login credentials
.
Table 6-2 Login Credentials
Username
Password
root
root
Содержание 6806800U29D
Страница 1: ...SharpStreamer Pro PCIE 7210 Installation and Use P N 6806800U29D September 2017...
Страница 8: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 8 Contents...
Страница 10: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 10 List of Tables...
Страница 12: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 12 List of Figures...
Страница 20: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D Safety Notes 20...
Страница 24: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D Sicherheitshinweise 24...
Страница 30: ...Introduction SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 30...
Страница 48: ...Functional Description SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 48...
Страница 70: ...Controls Indicators and Connectors SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 70...
Страница 92: ...BIOS SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 92...
Страница 108: ...Base Operating System SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 108...
Страница 140: ...MaxCore Firmware Upgrade SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 140...
Страница 142: ...Related Documentation SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29D 142...
Страница 143: ......